header advert
Results 1 - 20 of 95
Results per page:
Bone & Joint Open
Vol. 5, Issue 8 | Pages 637 - 643
6 Aug 2024
Abelleyra Lastoria D Casey L Beni R Papanastasiou AV Kamyab AA Devetzis K Scott CEH Hing CB

Aims. Our primary aim was to establish the proportion of female orthopaedic consultants who perform arthroplasty via cases submitted to the National Joint Registry (NJR), which covers England, Wales, Northern Ireland, the Isle of Man, and Guernsey. Secondary aims included comparing time since specialist registration, private practice participation, and number of hospitals worked in between male and female surgeons. Methods. Publicly available data from the NJR was extracted on the types of arthroplasty performed by each surgeon, and the number of procedures of each type undertaken. Each surgeon was cross-referenced with the General Medical Council (GMC) website, using GMC number to extract surgeon demographic data. These included sex, region of practice, and dates of full and specialist registration. Results. Of 2,895 surgeons contributing to the NJR in 2023, 102 (4%) were female. The highest proportions of female surgeons were among those who performed elbow (n = 25; 5%), shoulder (n = 24; 4%), and ankle (n = 8; 4%) arthroplasty. Hip (n = 66; 3%) and knee arthroplasty (n = 39; 2%) had the lowest female representation. Female surgeons had been practising for a median of 10.4 years since specialist registration compared to 13.7 years for males (p < 0.001). Northern Ireland was the region with the highest proportion of female arthroplasty surgeons (8%). A greater proportion of male surgeons worked in private practice (63% vs 24%; p < 0.001) and in multiple hospitals (74% vs 40%; p < 0.001). Conclusion. Only 4% of surgeons currently contributing cases to the NJR are female, with the highest proportion performing elbow arthroplasty (5%). Female orthopaedic surgeons in the NJR are earlier in their careers than male surgeons, and are less involved in private practice. There is a wide geographical variation in the proportion of female arthroplasty surgeons. Cite this article: Bone Jt Open 2024;5(8):637–643


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 211 - 211
1 Jul 2008
Candal-Couto J Gamble G Astley T Rothwell A Ball C
Full Access

The aim of the New Zealand Elbow Arthroplasty Register is to evaluate the provision of elbow arthroplasty across the entire country by both recording accurate technical information and measuring the clinical outcomes of all elbow replacements performed in New Zealand. An initial form is completed at the time of surgery which includes details of the patient, surgical indications, the surgical procedure, the implant and the operating surgeon. Six months following surgery, all registered patients are asked to complete a questionnaire to measure the pain and function of the replaced elbow and to comment on any post operative complications. Data from 99 consecutive primary and 16 revision elbow arthroplasties was prospectively collected from January 2000 till December 2003. Rheumatoid arthritis was the commonest indication (63 cases) and the outcome was significantly better than for trauma and osteoarthritis. The Coonrad-Morrey was the most commonly used prosthesis (86 cases) followed by the Kudo (eight cases) and the Acclaim (five cases). 21 surgeons performed elbow arthroplasty during the study period but only five performed on average more than one case per year. Their results at six months were statistically superior to those provided by other surgeons. The number of complications reported by patients and the revision rate within the study period was low. An infection was seen in only two patients. The New Zealand Elbow Arthroplasty Register has become a robust method of assessment of the provision of elbow arthroplasty within the country. Our findings support the idea that elbow arthroplasty should not be performed by general orthopaedic surgeons on an occasional basis


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2006
Spormann C Simmen B
Full Access

Introduction: The design of the GSB III elbow arthroplasty has essentially remained unchanged since 1978 until recently. Because of observations of aseptic loosening of the ulnar component, the ulnar stem was changed in an excentric curved shape. The aim of the present study was to assess the clinical and radiographic outcome after more than 2 years of follow up with the new ulnar stem shape. Patients and methods: Between january 2000 and august 2002, 34 patients had undergone 36 total elbow replacements with the GSB III device with a new curved ulnar shape. Nineteen patients (20 elbows) underwent the operation for the first elbow arthroplasty and 16 patients underwent revision surgery. The mean follow up was 35 months (R: 25–49). The subjective satisfaction and pain intensity were assessed. Clinical exam recorded range of motion and strength. Radiographs were analysed for implant loosening and osteolysis. Results: There was a significant improvement of the average range of motion in flexion-extension from pre-operative 82degree to postoperative 105degree for all 36 elbows (t-test, p< 0,005). The 20 cases with primary elbow arthroplasty showed a significant improvement in the average range of flexion-extension from 76degree to 106degree (t-test, p< 0,001). The subjective assessment for satisfaction averaged 93 per cent at the time of follow up. For the 16 patients with revision elbow arthroplasty, the average range of flexion-extension improved from 90degree to 103degree (p< 0,01). The mean subjective satisfaction rated at 94 per cent. One case showed a radiolucent line at the ulnar component which remained unchanged at follow up. There was no component loosening. Discussion: The new excentric curved ulnar component shows no case of component loosening in our series for primary and revision elbow arthroplasty after 2 years. The range of motion and patient satisfaction are promising


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 581 - 581
1 Dec 2013
Weijia C Nagamine R
Full Access

Objective:. Total elbow joint arthroplasty has limited longevity and is therefore not appropriate for younger rheumatoid arthritis patients. Arthroplasty using an inter-positional membrane may be another surgical option for this population. However, clinical results for joint arthroplasty using the inter-positional membrane have not traditionally been favorable because rheumatoid activity could not be controlled. Today, rheumatoid activity can be controlled with biologics; therefore, the utility of the inter-positional membrane procedure was re-evaluated. Methods:. An 8×6 cm sheet of fascia was detached from the patient's tensor fascia lata muscle to produce a JK membrane. The fascia was stretched on a frame and kept in a 2% chromic acid potassium solution for 24 hours. Then, the fascia was exposed to direct sunlight in order to reduce the dichromic acid. The fascia was washed out in running water for 24 hours and was then stored in phenol with the addition of 70% alcohol. Elbow arthroplasties were performed on three elbow joints in two young female patients. The first case had a significantly damaged right elbow joint with severe joint dysfunction. A JK membrane arthroplasty was done for the first case in 2003, when this patient was 34 years old. Biologics were administered with methotrexate after the surgery. The second case demonstrated bilateral ankylosed elbows due to idiopathic juvenile arthritis. Bilateral JK membrane arthroplasties were performed in 2010, when this patient was 32 years old. Several operative and manual manipulations were necessary in order to increase the range of motion following surgery. Biologics were administered with cyclosporine. Results:. Joint function was significantly improved in all three joints without pain after the JK membrane elbow arthroplasties. In case one, the JOA (Japan Orthopaedic Association) elbow score improved from 21 points before surgery to 85 points after surgery and active elbow flexion improved to 110 degrees following surgery. In case two, the JOA elbow score was 55 and 82 points in the right elbow and 52 and 83 points in left elbow before and after surgery, respectively. In case two, active flexion improved to 120 degrees for the right elbow and 110 degrees for the left elbow following surgery. RA was well controlled in both patients. Conclusion:. Elbow arthroplasty using an inter-positional membrane appears to be useful in young patients when RA activity is controlled with biologics


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 361 - 361
1 Jul 2008
Waters T Noorani A Malone A Bayley J Lambert S
Full Access

We report 5 cases of linked shoulder and elbow replacement (LSER) following failure of single-joint arthroplasty. Whilst total humeral replacement has been reported for treatment following resection for tumour we know of no reports of linked shoulder and elbow prostheses for arthropathy alone. Between May and December 2005, 2 patients with total elbow arthroplasty and 3 patients with total shoulder arthroplasty were revised to LSER for loosening of the long humeral stems or periprosthetic fracture. Custom-made prostheses were produced using computer-aided design and manufacture technology. There were no early complications including infection. All 5 patients reported early improvement of symptoms, with the ability to bear weight axially through the limb, restored. This technique avoids the problem of a stress riser between the stems of separate shoulder and elbow replacements and solves the problem of salvage of long-stemmed implants where no further humeral fixation is possible


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 115 - 115
1 May 2012
A. H R. A D. C N. B
Full Access

Introduction. Cement pressurisation in the distal humerus is technically difficult due to the anatomy of the humeral intramedullary (IM) cavity. Conventional cement restrictors often migrate proximally or leak, reducing the effect of pressurisation during implantation. Theoretically with a better cement bone interdigitation, the longevity of the elbow replacement can be improved. The aim of this cadaveric study was to evaluate the usefulness of a novel technique for cementation. Method. Eight paired fresh frozen cadaveric elbows were randomly allocated to conventional cementing techniques or cementing using a paediatric foley catheter as a temporary restrictor. The traditional cementing technique consisted of canal preparation using irrigation, brushing and drying prior to cementation, with no use of a cement restrictor. The new technique involved same canal preparation but prior to cementation a size 8 foley catheter was introduced and the balloon inflated to act as a temporary cement restrictor. The humeri were cut into 10mm sections. Each slice was photographed and radiographed. This dual imaging technique was used to establish the best methodology for evaluation of cement penetration. Cement penetration was calculated as a ratio of the area of intra-medullary cavity occupied by the cement. Results. There was no significant difference between the photographic and radiographic method of measuring cement penetration. Cement penetration was significantly better in the foley catheter group (P = 0.002-0.037). The maximum penetration was observed in the most distal 2-5cm. Conclusion. The foley catheter technique consistently and significantly achieved a better cement interdigitation into the cancellous bone, without leaving a void in the cement. This study has demonstrated a new cementing technique for elbow arthroplasty, utilising a paediatric foley catheter as a temporary humeral intra-medullary plug, increasing cement pressurisation and restricting proximal cement migration. Future studies using this methodology will not require supplementation of photographs with radiographic analysis


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 163 - 163
1 Apr 2005
Little C Graham A Ionanides G Carr A
Full Access

A systematic review of the English language literature has suggested that the performance of linked and unlinked elbow replacement implants differ in terms of function, survival and mode of failure; however, in this review, only one comparative series using contemporary implants was identified. We have performed a cohort study of Kudo, Souter-Strathclyde and Coonrad-Morrey elbow replacements performed at a single centre by or under the direct supervision of a single Consultant shoulder and elbow surgeon to see if these findings were reflected in clinical practice. The first forty implantations in patients with Rheumatoid arthritis for each device have been reviewed with respect to surgical complications, elbow function and implant survival. The follow-up was shorter for the Coonrad-Morrey cohort. In terms of pain relief and range of motion, the performance of the implants was comparable. The mode of failure was different, with no dislocations/ instability seen with the linked Coonrad-Morrey implants. The loosening rate of the Coonrad-Morrey implants (both clinical and radiographic) was lower, albeit with a shorter follow-up period. The loosening rates seen in this series were higher than those previously reported in the English language literature. We conclude that the functional performance of the implants, at similar stages of the surgical learning curves, are similar in patients with Rheumatoid arthritis, but that use of a linked implant removes the risk of post-operative instability and may reduce the risk of the radiographic and clinical loosening


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 121 - 121
1 Feb 2003
Malone AA Taylor AJN Fyfe IS
Full Access

This study assesses long term performance of the Souter-Strathclyde elbow arthroplasty. From 1984 to 1999, 68 Souter-Strathclyde prostheses were inserted in 53 patients; nine patients died, one was lost and 38 (88%) had full clinical examination. Mean survival was 72 months (range 8 to 187), 25 elbows survived to 5-year follow up, with improvement in pain, motion, stability and function. Mayo score was satisfactory in 92% of all 68 elbows. Complications occurred in 13 elbows (19%) and 14 elbows were revised for instability (six), fracture (three), loosening (three) and intraoperative problems (two). Survivorship at 10 years was 74% (95% Confidence Interval ± 7. 7)


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 67 - 67
1 Jan 2003
Kalogrianitis S Rawal A Pydisetty R Sinopidis C Yin Q Frostick S
Full Access

Introduction: Distal humeral fractures represent a constant challenge to the most experienced surgeon. This is the first report of the use of an unlinked prosthesis for the treatment of distal humeral fractures in elderly persons. Materials and Methods: From July 2000 to June 2001, 9 iBP elbow arthroplasties were performed in patients with acute fractures of the distal humerus. The average age of the group was 71 years. The mean interval between injury and TER was 11 days. The follow-up period averaged 12 months (range 5 to 16). Results: Functional outcome was evaluated with patient-completed questionnaires. All patients had a flexion contracture of the elbow ranging from 15 to 30 degrees. All patients were able to perform daily activities, pain relief was satisfactory and patient satisfaction was high. All elbows met the criteria for functional motion and were stable at the latest follow-up examination. There were no major complications such as dislocation, ulnar nerve dysfunction or deep infection. Conclusion: Unlinked non-congruous elbow arthroplasty when combined with a surgical exposure that allows proper soft tissue balance and instrumentation that enables correct positioning of the components can be a successful alternative in the management of acute distal humeral fractures in selected patients when conventional fixation is not a viable option


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 133 - 134
1 Mar 2006
John M Angst F Pap G Flury M Herren D Schwyzer H Simmen B
Full Access

Introduction: In the evaluation of the major joints, self assessment tools have become wide spread aiming at a more precise quantification of joint function. Different tools have been developed for the elbow joint. However, there are only few data on the relationship between subjective self-assessment of joint function and objective measures. We developed a comprehensive assessment set for the evaluation of subjective elbow function and objective clinical findings and investigate long-term results after implantation of GSB III Elbow arthroplasties in a first study. The PREE-G was cross-culturally adapted, following the recommendations of the American Association of Orthopedic Surgeons. Material and Methods: 79 patients (56 female, 23 male, mean age 64 years) after elbow arthroplasty between 1984 and 1996 due to rheumatoid (59) or posttraumatic (20) arthritis underwent an assessment of the joint function using the PREE, the Short Form 36 (SF-36), the Disabilities of Arm, Shoulder, Hand (DASH)) and the modified American Shoulder and Elbow Surgeons (mASES) for a clinical evaluation. In 62 patients implantation was performed unilaterally and in 17 patients bilaterally, resulting in 96 elbow joints altogether. The mean follow up time was 11,2 years. Results: In the SF-36 score, the mean physical component scale (PCS) was worse (37,2 vs 41,7, p=0,004), the mean mental component scale (MCS) better (52,3 vs 50,3, p=0,092) than normative values of a German population. Subjective assessment by the PREE revealed a mean of 66,8, by the mASES of 63,1 and by the DASH of 56,5 points. Clinical examination resulted in a mean mASES score of 71,6 points. Comparison between the patients self assessment and the objective score revealed a significant correlation between the DASH (r=0,46, p< 0,001), PREE (p=0,54, p< 0,001) and mASES (r=0,60, p< 0,001) with the clinical mASES. In contrast, no significant correlation was found between the physical component scale (PCS) and mental component scale (MCS) of SF-36 and the clinical mASES. Also the patients assessment scores DASH, PREE and mASES showed a strong significant correlation among one another (r=0,74–0,92, p< 0,001) and (PCS) (r=0,58–0,75, p< 0,001) but not with the (MCS) of SF-36. Conclusion: Assessment of long term results after elbow arthroplasty yielded favourable clinical and subjective results. The clinical outcome tended to be higher than results of the patient self-rated scores. Hereby, the newly developed assessment set proved to be a feasible tool for a comprehensive assessment of elbow function. In addition to clinical outcome assessment, with this set it is possible to gain important and new insights on the relationship between objective measures and subjective patients-assessment of elbow disorders and postoperative conditions


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 191 - 191
1 Jul 2002
Malone A Taylor A Fife I
Full Access

This study assesses the clinical performance of the Souter-Strathclyde elbow arthroplasty with a standardised index and long term survivorship analysis. We undertook assessment of 68 primary Souter-Strathclyde total elbow replacements. Of 53 patients assessed with pre-operative Souter-Strathclyde charts, nine died and one was lost to follow-up, 43 had radiographic and telephone review, and 38 (88%) had clinical examination according to the Mayo Elbow Performance Index. Survival of the 43 elbows was to a mean of 72 months (range: eight to 187 months) with improvement in pain, motion, stability and function. Eight of 10 elbows in deceased patients had satisfactory scores at the last assessment. Ulnar neuropraxia occurred in eight elbows (12%), persistent sensory deficit in two (3%) and motor deficit in one. Two triceps abscesses required local skin flap cover. Revision was undertaken in 14 elbows (20%) for instability (six) bony injury (three), loosening (three) and intraoperative problems (two). The survivorship at 13 years was 74% with 62 (91%) of all elbows achieving a satisfactory Mayo score


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 408 - 408
1 Apr 2004
Malone A Taylor AJN Fyfe IS
Full Access

This study assesses the clinical performance of the Souter-Strathclyde elbow arthroplasty with a standardised index and long-term survivorship analysis. We undertook assessment of 68 primary Souter-Strathclyde total elbow replacements. Of 53 patients assessed with pre-operative Souter-Strathclyde charts, nine died and one was lost to follow-up, 43 had radiographic and telephone review, and 38 (88%) had clinical examination according to the Mayo Elbow Performance Index. Survival of the 43 elbows was to a mean of 72 months (range 8 to 187). A cohort of 25 elbows available for review with > 5-year follow up had improvement in pain, motion, stability and function. Eight of ten elbows in deceased patients had satisfactory scores at the last assessment. Ulnar neuropraxia occurred in eight elbows (12%), persistent sensory deficit in two (3%) and motor deficit in one. Two triceps abscesses required local skin flap cover. Revision was undertaken in 14 elbows (20%) for instability (6) bony injury (3), loosening (3) and intraoperative problems (2). The survivorship at 13 years was 74% with 62 (91%) of all elbows achieving a satisfactory Mayo score


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2006
Ayana G Bransby-Zachary M
Full Access

Aims: To evaluate the short to medium term outcome of the Souter-Strathclyde prosthesis when used as a primary elbow arthroplasty in rheumatoid arthritis. Introduction: The Souter-Strathclyde prosthesis has been evaluated in several studies. In our hospital the operation is carried out using the same strict precautions as for lower limb arthroplasty. At the onset of surgery the ulnar nerve is handled minimally. This study looked at infection and complication rates, and also at outcome. Methods: The operations were carried out in laminar flow theatres and scrubbed staff wore exhaust suits. At the start of the procedure the ulnar nerve was decompressed, but not mobilised from its bed, and held loosely with tape while being kept moist. Cases were identified from theatre and implant records. 61 implants in 53 patients were identified. Complication and revision rates were established from case sheets. Of this group 19 patients had died, leaving 40 implants in 34 patients suitable for review. Case notes were analysed. Patients were contacted by post and were requested to fill out a DASH form. 30 patients (34 implants) responded; 2 declined to be involved leaving 31 implants in 28 patients to analyse, 78% of those available. Results: From the 61 implants there were 4 complications within the first year; one ulnar nerve palsy – transient, one dislocated prosthesis – open reduction, two wound infections. The infection rate is thus 3.3%. Overall to date 4 implants from 61 required revision, a rate of 6.6% (range 13–92 months, mean 37 months). Reasons – one loose, two periprosthetic fractures and one infection. Mean follow up at clinic was 74 months (range 36–120). Mean DASH score at follow up was 48.7 (range 4.5–81.8). Conclusion: The lower incidence of ulnar nerve palsy, compared to published studies, may be attributable to the surgical technique. The use of laminar flow theatres and exhaust suits may account for the lower infection rates. The complication rate and revision rate is favourable compared to previous studies


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 160 - 160
1 Apr 2005
Ayana GE Bransby-Zachary M
Full Access

Aim: To evaluate the short to medium term outcome of the Souter-Strathclyde prosthesis when used as a primary elbow arthroplasty in rheumatoid arthritis. Introduction: The Souter-Strathclyde prosthesis has been evaluated in several studies. In our hospital the operation is carried out using the same strict precautions as for lower limb arthroplasty. At the onset of surgery the ulnar nerve is handled minimally. This study looked at infection and complication rates, and also at outcome. Methods: The operations were carried out in laminar flow theatres with exhaust suits. At the start of the procedure the ulnar nerve was decompressed, but not mobilised from its bed, and held loosely with tape while being kept moist. Cases were identified from theatre and implant records. 61 implants in 53 patients were identified. Complication and revision rates were established from case sheets. Of this group 19 patients had died leaving 40 implants in 34 patients suitable for review. Case notes were analysed. Patients were contacted by post and were asked to fill out a DASH form. 30 patients (34 implants) responded. 26 patients (30 implants) attended a review clinic. Results: From the 61 implants there were 4 complications (one ulnar nerve dysthesia – transient, one dislocated prosthesis – open reduction, two wound infections) within the first year. Overall, 4 implants from 62 required revision, a rate of 6.5% (range 11–92 months, mean 37 months). Reasons – One loose, two periprosthetic fractures and one infection. Mean follow up was 74 months (range 36–120). Mean DASH score at follow up was 48.7 (range 4.5–81.8). Conclusion: The low incidence of ulnar nerve palsy, compared to published studies, may be attributable to the surgical technique. The use of laminar flow theatres and exhaust suits may account for the low infection rate. The complication rate and revision rate is comparable to previous published studies


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 35 - 35
1 Mar 2010
Veillette C Cil A Sanchez-Sotelo J Morrey BF
Full Access

Purpose: The long-term experience of linked semicon-strained total elbow arthroplasty was investigated as a salvage procedure for patients with distal humerus non-union not amenable to internal fixation. Method: Ninety-two consecutive total elbow arthroplasties performed for the treatment of a distal humeral nonunion were reviewed at an average follow-up of 6.5 years (range, 0.5 to 20.3 years). There were twenty-two men and sixty-nine women with an average age of sixtyfive years (range, twenty-two to eighty-four years) at the time of elbow replacement. Seventy-six elbows (83 per cent) had undergone prior surgery, with an average of two previous operations (range, one to ten). Five elbows had had at least one prior operation due to infection. Results: Seventy-nine per cent of the patients had no pain or mild pain at latest follow-up compared with moderate or severe pain in 86 percent prior to surgery. Mean extension was improved from thirty-seven to twenty-two degrees and mean flexion from 106 to 135 degrees. Joint stability was restored in all patients, including nine with a grossly flail elbow. Complications included aseptic loosening in sixteen (four with periprosthetic fractures), component fracture in five, deep infection in five (three with previous infection), and bushing wear in one patient. At most recent follow-up, 85 per cent of the patients were satisfied with their outcome. Survivorship for not requiring removal or revision for any cause was 95.7 per cent at two years, 82.1 per cent at five years, 65.3 per cent at ten and fifteen years. Factors that increased the risk of implant failure were patient age less than sixty-five, two or more prior surgeries, and history of previous infection. Conclusion: Linked semiconstrained total elbow arthroplasty provides a reliable salvage procedure to provide pain relief and restoration of motion and function in patients with distal humerus nonunion not amenable to internal fixation. Risk factors for failure include younger patients, multiple previous surgeries, and history of infection


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 121 - 121
1 May 2011
Amirfeyz R Hughes A Clark D Blewitt N
Full Access

Cement pressurisation in the distal humerus is technically difficult due to the anatomy of the humeral intramedullary (IM) cavity. Conventional cement restrictors often migrate proximally, reducing the effect of pressurisation during arthroplasty. Theoretically with a better cement bone interdigitation, the longevity of the elbow replacement can be improved. The aim of this cadaveric study was to evaluate the usefulness of a novel technique for cementation. Eight paired cadaveric elbows were used. The sides were randomly allocated to the conventional cementation group and pressurisation using a foley cathetre used as a cement restrictor. The cathetre was inserted into the IM canal after thorough washout and drying the cavity. The balloon inflated to act as a cement restrictor. Cementation was then performed and the cathetre removed just prior to cement setting. Radiographs of each pair was taken. Each distal humerus sample was cut in 1 cm increments starting from proximal part of the coronoid fossa. The slices were also radiographed to assess cement-bone interdigitation. The area of IM canal and the cement were calculated. The paired samples were compared. The new technique consistently and significantly achieved a better cement interdigitation into the cancellous bone. The maximum penetration was observed in the proximal 1–3 cms from the coronoid fossa. According to previous studies, this area is the most common part involved in cement failure and loosening. This study confirms the effectiveness of a foley cathetre as a cement restrictor. The ease of the technique and excellent pressurisation achived support its use


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 141 - 141
1 Apr 2005
Alnot J Hemon C El Abiad R Masmejean Guepar
Full Access

Purpose: We conducted a retrospective study of 20 total elbow prostheses GUEPAR humerocubital and humeroradial (G3) implanted in 19 patients with rheumatoid arthritis. This anatomic metal-polyethylene prosthesis is available in a left and right model and in two sizes, large and small. A radial head prosthesis is now available in addition to the humerocubital prosthesis. The radial head prosthesis has an intramedullary metallic stem and a mobile polyethylene cup which comes in several sizes.

Material and methods: Among 20 prostheses implanted between 1997 and 2001, four were first-generation prostheses which did not have a radial head. At three to four years, these four prostheses developed valgus instability with deterioration of the polyethylene of the cubital piece requiring revision with a new generation GUEPAR associated with a radial head. This gave two good results and two failures revised with a semi-constrained prosthesis. For the 16 other cases of rheumatoid disease, the G3 humerocubital prosthesis associated with a radial head was inserted. These 16 prostheses were followed two years and were retained for this analysis. The posterior approach was used with inverted-V section of the triceps using the surgical technique recommended by the promoters. Patients had permanent severe to moderate pain. The Mayo Clinic score (1992 including daily life activities) was 33/100. Radiographically, seven elbows were Larsen grade III, nine grade IV, seven grade IIA and nine grade IIIb (Larsen classification modified by the Mayo Clinic).

Results: All patients were reviewed with mean follow-up of two years (1–5). The Mayo Clinic score improved from 33/100 to33/90 with outcome considered excellent in 15 elbows and fair in one.

Discussion: We recommend total elbow prostheses for rheumatoid arthritis patients. Semi-constrained prostheses have indications in certain cases of massive destruction, but the minimally or non-constrained gliding prostheses, such as the GUEPAR prosthesis, are part of the evolution of these prostheses, just as was the case for knee prostheses. These good results can be expected to persist over time.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 196 - 196
1 Jul 2002
Singh R Pooley J
Full Access

We studied 12 patients (13 elbows) who underwent total elbow replacement (TER) using the Kudo Mk IV or V prosthesis between 1989 and 1997. There were eight females and four males (mean age: 61 years, range: 38–74 years). The diagnosis was Rheumatoid arthritis in 10 patients and osteoarthritis in two patients. In each patient the initial result was classified as either excellent or good. All these patients then reported the recurrence of severe pain at a mean of four years from the time of the primary operation. Radiographic examination demonstrated fracture of the humeral stem in 10 elbows and subluxation of the joint in three elbows. The fractured humeral components were exchanged for long stem components. The three subluxated elbows were found to have undergone delamination and loosening of the ulnar components which were revised. One of these required revision to a linked prosthesis due to bone loss.

In each case metallosis was found involving principally the synovial tissues which were as far as possible excised. Each patient regained a similar range of movement to that following the primary arthroplasty but continues to experience episodes of pain requiring anti-inflammatory medication. This is in contrast to our patients requiring revision procedures for implant loosening or instability who have become pain free.

We conclude that the development of metallosis complicating mechanical implant failure predisposes to persisting symptoms following revision arthroplasty and recommend that this should be undertaken sooner rather than later when mechanical failure is detected.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 355 - 355
1 Jul 2008
Nuttall D Trail I Stanley J
Full Access

To measure any observed migration and rotation of humeral and ulnar components using radiostereometric analysis. From 2002–2004 in a prospective ongoing study, twelve elbows in patients treated with either a linked or unlinked Acclaim total elbow prosthesis were included in a radiostereometry study. Six tantalum markers were introduced into the humerus another three markers were located on a humeral component. Four markers were placed in to ulna and three markers located on the ulnar component. RSA radiographs were taken postoperatively, six, twelve and twenty-four months. The radiographs were digitised and analysed using UmRSA software. The relative movement of the humeral and ulnar implants with respect to the bone was measured. At twelve months, the largest segment translation of the humeral component was in the anterior/posterior direction with a mean of 0.44mm followed by medial/lateral translation of 0.39 mm; there was minimal proximal/ distal translation or with a mean of 0.16mm. Paired t-tests between twelve and 24 months segment translation data showed the mean differences to be no more than 0.056mm. The largest rotation at twelve months was anteversion/retroversion with a mean of 2.40deg, anterior tilt had a mean of 1.20deg and varus/valgus tilt was minimal mean 0.60deg. Mean difference between twelve and 24 months segment rotation was no more than 0.30deg. In contrast, humeral tip motion produced a mean of 1.1mm at 12 months dominated by movement in the plane horizontal plane with a mean difference at 24 months of 0.06mm. No patients could be measured for segment micromotion of the ulnar component due to technical difficulty in visualising tantalum markers in the ulna. Early micromotion of the Acclaim humeral implant occurs mostly by rotation about the vertical axis accompanied by anterior tilt. This motion reaches a plateau at 12 months after operation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 131 - 132
1 Mar 2008
Dunham C Austman R King G Johnson J Dunning C
Full Access

Purpose: Anterior flanges have been added to the humeral components of some total elbow arthroplasty systems. Surgeons have the option of placing a wedge of bone or bone cement between the anterior surface of the humerus and the flange in an effort to improve implant stability and load transfer. The purpose of this study was to quantify the cortical strains in the humerus after arthroplasty for different materials placed behind the flange.

Methods: Five fresh-frozen cadaveric distal humeri were thawed and cleaned of all soft tissues. Strain gauges were applied to the anterior and posterior surfaces to record bending and axial strains. The bending gauges were positioned just proximal to the location of the flange tip. Cantilever bending and axial compression were applied using a materials testing machine. Following intact testing, the humeral component of a total elbow was implanted by an experienced surgeon and fixed using bone cement. Testing was repeated three times, each with a different material behind the flange: no graft (simulating a humeral component without an anterior flange), cancellous bone graft, and cement graft. Strains were normalized to the intact state and for the applied moments. Data were analyzed using repeated-measure ANOVAs (p< 0.05).

Results: For bending, the strain values were approximately 80% of the intact values with no graft material, 80% with the bone graft, and 87% with the cement graft. These differences among the graft materials were not significant (p=0.5). Similar results were found for the axial strains (p=0.3).

Conclusions: The intention of the anterior flange is to transfer a portion of the load carried by the implant stem to the distal humerus, thereby reducing stress-shielding and improving strength of the construct. In this investigation that employed bending and axial loads, the presence of an anterior flange had no significant effect on load transfer through the distal humerus regardless of graft material used. This would suggest that for the humeral component employed in this study, the flange might not be fulfilling its intended purpose.