Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 183 - 183
1 Mar 2008
Sanghrajka A Amin A Briggs T Cannon S Blunn G Unwin P
Full Access

The purpose of this study was to determine whether the low rate of mechanical loosening of the SMILES rotating hinge distal femoral endoprosthesis relates to the hydroxyapatite (HA)-coated, grooved collar of the femoral component. A database was used to identify two groups of cases of primary distal femoral replacement with a custom-designed and manufactured SMILES endoprosthesis at our unit; those with the collared femoral component (“collar group”), and those without a collar (“non-collargroup”). From these two groups, patients were pair-matched for age and length of bone resection. A retrospective review of serial biplanar pairs of radiographs of each patient, assessing radiolucent lines and extracortical bone pedicle. 11 matched pairs were identified, (14 females, 8 males), with a mean age of 36 years, (range 16–66). The pathology was primary bone tumour in 20 cases, (17 malignant, 3 benign), and metastatic disease in 2 cases. Mean length of follow-up was 85 months, (range 27–122). Radiolucent line score (RLS) progression over time was significantly lower in the collar group, (0.01 vs 0.73, p=0.001) (fig. 1 & 2), as was the mean final RLS, (2.72 vs 7.81, p=0.02). Mean RLS per radiographic quadrant was 0.56 in cases in which a bony pedicle was ingrown onto the prosthesis, (exclusively in the collared-group), 2.41 in cases in which the pedicle was not ingrown, (most prevalent in the non-collared group), and 1.02 in those cases without any pedicle formation, (ANOVA analysis, p=0.0002). This study demonstrates that the HA-coated, grooved collar significantly reduces the progression of radiolucent lines, and consequently the overall RLS, explaining the reduced rate of mechanical loosening of the collared endoprosthesis. A bony pedicle that does not incorporate onto the prosthesis surface may be associated with an increase in radiographic loosening


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 77 - 77
1 Mar 2005
Sanghrajka A Amin A Briggs T Cannon S Blunn G Unwin P
Full Access

Purpose: The purpose of this study was to determine whether the low rate of mechanical loosening of the SMILES rotating hinge distal femoral endoprosthesis relates to the hydroxyapatite (HA)-coated, grooved collar of the femoral component. Methods and results: A database was used to identify two groups of cases of primary distal femoral replacement with a custom-designed and manufactured SMILES endoprosthesis at our unit; those with the collared femoral component (“collar group”), and those without a collar (“non-collar group”). From these two groups, patients were pair-matched for age and length of bone resection. We performed a retrospective review of serial biplanar pairs of radiographs of each patient, assessing radiolucent lines and extracortical bone pedicle. 11 matched pairs were identified, (14 females, 8 males), with a mean age of 36 years, (range 16–66). The pathology was primary bone tumour in 20 cases, (17 malignant, 3 benign), and metastatic disease in 2 cases. Mean length of follow-up was 85 months, (range 27–122). Radiolucent line score (RLS) progression over time was significantly lower in the collar group, (0.01 vs 0.73, p=0.001) (fig. 1 & 2), as was the mean final RLS, (2.72 vs 7.81, p=0.02). Mean RLS per radiographic quadrant was 0.56 in cases in which a bony pedicle was ingrown onto the prosthesis, (exclusively in the collared-group), 2.41 in cases in which the pedicle was not ingrown, (most prevalent in the non-collared group), and 1.02 in those cases without any pedicle formation, (ANOVA analysis, p=0.0002). Conclusion: This study demonstrates that the HA-coated, grooved collar significantly reduces the progression of radiolucent lines, and consequently the overall RLS, explaining the reduced rate of mechanical loosening of the SMILES prosthesis. A bony pedicle that does not incorporate onto the prosthesis surface may be associated with an increase in radiographic loosening


Bone & Joint Open
Vol. 2, Issue 1 | Pages 3 - 8
1 Jan 2021
Costa-Paz M Muscolo DL Ayerza MA Sanchez M Astoul Bonorino J Yacuzzi C Carbo L

Aims

Our purpose was to describe an unusual series of 21 patients with fungal osteomyelitis after an anterior cruciate ligament reconstruction (ACL-R).

Methods

We present a case-series of consecutive patients treated at our institution due to a severe fungal osteomyelitis after an arthroscopic ACL-R from November 2005 to March 2015. Patients were referred to our institution from different areas of our country. We evaluated the amount of bone resection required, type of final reconstructive procedure performed, and Musculoskeletal Tumor Society (MSTS) functional score.


Bone & Joint Research
Vol. 9, Issue 7 | Pages 333 - 340
1 Jul 2020
Mumith A Coathup M Edwards TC Gikas P Aston W Blunn G

Aims

Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early radiological signs of aseptic loosening in patients with massive distal femoral prostheses.

Methods

A retrospective radiological analysis was performed on adult patients with distal femoral arthroplasties. In all, 16 patients were included in the chemotherapy group with 18 patients in the non-chemotherapy control group. Annual radiographs were analyzed for three years postoperatively. Dimensions of the bony pedicle, osseointegration of the hydroxyapatite (HA) collar surface, bone resorption at the implant shoulder, and radiolucent line (RLL) formation around the cemented component were analyzed.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 4 - 10
1 Oct 2019
Tsoi K Samuel A Jeys LM Ashford RU Gregory JJ