Advertisement for orthosearch.org.uk
Results 1 - 20 of 121
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 138 - 138
1 Jan 2016
Fujita H Okumura T Hara H Harada H Toda H Nishimura R Tominaga T
Full Access

Background. Cement implantation syndrome characterized by hypotension, hypoxemia, cardiac arrhythmia or arrest has been reported in the literature. The purpose of the present study was to monitor blood pressure soon after cementing. Methods. The present study includes 178 cases 204 joints of primary THA with an average age at operation of 64.5 years old (ranging 35 to 89). Under general anesthesia, both components were cemented using antero-lateral approach. Systolic arterial blood pressure during cementing acetabular and femoral components was monitored until 5 minutes with 1 minute interval. The maximum regulation ratio (MRR) was calculated as (maximum change blood pressureblood pressure before cement insertion) divided by blood pressure before cement insertion. Results. No major complications such as cardiac arrest were observed. In most of the cases, blood pressure increased until 4 minutes for the acetabular side and 2 minutes for the femoral side, and then returned to the blood pressure before cement insertion gradually. In the acetabular side, average MRR was 11.2% (SD, 15.9; range, −26 to 80). In the femoral side, MRR was 6.4% (SD, 14.9; range, −31 to 65). There was statistical correlation between categories of MRR in the acetabular side and age at operation, the status of bleeding control of the acetabular side. When the bleeding control was judged as complete, blood pressure showed less tendency to decrease. When the bleeding control was judged as good, blood pressure showed more tendency to decrease. Conclusion. In the present study, major hypotension was not observed. Using third generation and IBBC cementing technique, when the bleeding control was judged as complete in the acetabular side, blood pressure showed less tendency to decrease


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 442 - 442
1 Nov 2011
Fujita H
Full Access

Purpose: Cement implantation syndrome characterized by hypotension, hypoxemia, cardiac arrhythmia or arrest has been reported in the literature. Pulmonary embolization is thought to be the main reason. In our institute, however, we have not experienced major hypotension during THA. To improve longevity of THA, interface bioactive bone cement technique combined with modern cementing technique has been used in our institute. Main principle of this technique is smearing hydroxyapatite granules on the dry bony surface followed by cement pressurization. The purpose of the present study was to monitor blood pressure soon after cementing. Method: The present study includes 91 cases of primary THA with an average age at operation of 64 years old (ranging 35 to 85). Under general anesthesia, both components were cemented using antero-lateral approach. Systolic arterial blood pressure was monitored until 5 minutes with 1 minute interval. The maximum regulation (MR%) was calculated as (maximum change blood pressureblood pressure before cement insertion) divided by blood pressure before cement insertion. Results: No major complications such as cardiac arrest were observed. In most of the cases, blood pressure increased until 4 minutes for the acetabular side and 2 minutes for the femoral side, and then returned to the blood pressure before cement insertion gradually. In the acetabular side, MR% was 10±13 (−19–40)%. In 52 joints (57.1%), MR% was between 10 to 40 %. In the femoral side, MR% was 5±12 (−20 to 31)%. In 32 joints (35.2%), MR% was between 10 to 31 %. Conclusion: In the present study, major hypotension was not observed. Blood pressure increases if left ventricle reacts to the pulmonary hypertension caused by micro-embolization. If major pulmonary embolization occurs, blood pressure decrease because left ventricle can not compensate for major pulmonary hypertension caused by mayor pulmonary embolization. By good cementing technique which includes washing out debris or fat and obtaining dry bony surface just before cementing, blood pressure soon after cementing was increased


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 115 - 115
1 Mar 2010
Ishii Y Noguchi H Matsuda Y Takeda M Higashihara T
Full Access

This study reports the comparison of the clinical use of a new tourniquet system for total knee arthroplasty that can determine its pressure in synchrony with systolic blood pressure (SBP) with the conventional that keeps the initial setting pressure. We prospectively applied the additional pressure of 100 mmHg based on the SBP recorded prior to skin incision to consecutive 72 procedures (conventional; initial 36, new; following 36). Six knees with the conventional and none of 5 with the new showed oozing blood in surgical field after sharp rise in SBP. According to statistically no difference of the perioperative blood loss without any tourniquet-related postoperative complications in both groups, the new system seemed to be much practical device especially for controlling a bloodless surgical field


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 189 - 194
1 Feb 2024
Donald N Eniola G Deierl K

Aims. Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative blood pressure, there are limited studies examining pre- and postoperative blood pressure. Methods. We conducted a prospective observational cohort study over a one-year period from December 2021 to December 2022. Patient demographic details, biochemical results, and haemodynamic observations were taken from electronic medical records. Statistical analysis was conducted with the Cox proportional hazards model, and the effects of independent variables estimated with the Wald statistic. Kaplan-Meier survival curves were estimated with the log-rank test. Results. A total of 528 patients were identified as suitable for inclusion. On multivariate analysis, postoperative hypotension of a systolic blood pressure (SBP) < 90 mmHg two to 24 hours after surgery showed an increased hazard ratio (HR) for 30-day mortality (HR 4.6 (95% confidence interval (CI) 2.3 to 8.9); p < 0.001) and was an independent risk factor accounting for sex (HR 2.7 (95% CI 1.4 to 5.2); p = 0.003), age (HR 1.1 (95% CI 1.0 to 1.1); p = 0.016), American Society of Anesthesiologists grade (HR 2.7 (95% CI 1.5 to 4.6); p < 0.001), time to theatre > 24 hours (HR 2.1 (95% CI 1.1 to 4.2); p = 0.025), and preoperative anaemia (HR 2.3 (95% CI 1.0 to 5.2); p = 0.043). A preoperative SBP of < 120 mmHg was close to achieving significance (HR 1.9 (95% CI 0.99 to 3.6); p = 0.052). Conclusion. Our study is the first to demonstrate that postoperative hypotension within the first 24 hours is an independent risk factor for 30-day mortality after hip fracture surgery. Clinicians should recognize patients who have a SBP of < 90 mmHg in the early postoperative period, and be aware of the increased mortality risk in this specific cohort who may benefit from a closer level of monitoring and early intervention. Cite this article: Bone Joint J 2024;106-B(2):189–194


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 97 - 97
17 Apr 2023
Gupta P Butt S Mahajan R Galhoum A Lakdawala A
Full Access

Prompt mobilisation after the Fracture neck of femur surgery is one of the important key performance index (‘KPI caterpillar charts’ 2021) affecting the overall functional outcome and mortality. Better control of peri-operative blood pressure and minimal alteration of renal profile as a result of surgery and anaesthesia may have an implication on early post-operative mobilisation. Aim was to evaluate perioperative blood pressure measurements (duration of fall of systolic BP below the critical level of 90mmHg) and effect on the post-operative renal profile with the newer short acting spinal anaesthetic agent (prilocaine and chlorprocaine) used alongside the commonly used regional nerve block. 20 patients were randomly selected who were given the newer short acting spinal anaesthetic agent along with a regional nerve block between May 2019 and February 2020. Anaesthetic charts were reviewed from all patients for data collection. The assessment criteria for perioperative hypotension: Duration of systolic blood pressure less than 90 mm of Hg and change of pre and post operative renal functions. Only one patient had a significant drop in systolic BP less than 90mmHg (25 minutes). 3 other patients had a momentary fall of systolic BP of less than 5 minutes. None of the above patients had mortality and had negligible change in pre and post op renal function. Only one patient in this cohort had elevation of post-operative creatinine levels but did not have any mortality. Only 1 patient died on day 3 post operatively who had multiple comorbidities and was under evaluation for GI cancer. Even in this patient the peri-operative blood pressure was well maintained (never below 90mmHg systolic) and post-operative renal function was also shown to have improved (309 pre-operatively to 150 post-operatively) in this patient. The use of short-acting spinal anaesthesia has shown to be associated with a better control of blood pressure and end organ perfusion, less adverse effects on renal function leading to early mobilisation and a more favourable patient outcome with reduced mortality, earlier mobilisation, shorter hospital stay and earlier discharge in this elderly patient cohort


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 23 - 23
1 Oct 2022
Bhide J Hemming R Davies J
Full Access

Purpose of study and background. Psychological factors are considered to play a role in development and maintenance of chronic low back pain (CLBP). Stress or anxiety can change pain sensitivity; however, this has predominantly been studied in healthy individuals with limited work in individuals with musculoskeletal pain. The objective of this study was to quantify the effect of acute exposure to a psychosocial stressor on mechanical pain sensitivity in individuals with and without CLBP. Summary of methods and results. Six individuals with CLBP and 10 individuals without CLBP performed a 10-minute computer task under conditions of low and high psychosocial stress. Psychosocial stress was manipulated using mental maths and memory tasks combined with social evaluative threat. The effect of the stressor was evaluated using blood pressure, heart rate and the state anxiety component of the Spielberger State-Trait Anxiety Index. Mechanical pressure pain threshold (PPT) was recorded on the tibialis anterior muscle using a handheld digital pressure algometer. The stress manipulation increased self-reported anxiety (p<0.001), but not blood pressure or heart rate (p>0.06). Change in PPT from low to high stress was greater in the CLBP group (median ΔPPT = −0.5 kg/cm. 2. ) than in the control group (−0.15 kg/cm. 2. ; p=0.005). Conclusion. Individuals experienced an increase in pain sensitivity after acute exposure to a stressor designed to mimic low-level workplace stressors, and this increase was greater in individuals with CLBP than asymptomatic individuals. These results indicate that this experimental model can be used to study links between pain sensitivity and psychosocial stressors and increase our understanding of their potential role in CLBP. Conflicts of Interest: No conflicts of interest. Sources of funding: No funding obtained


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 13 - 13
1 Dec 2021
Ramesh K Yusuf M Makaram N Milton R Mathew A Srinivasan M
Full Access

Abstract. Objective. To investigate the safety and cost-effectiveness of interscalene brachial plexus block/regional anaesthesia (ISB-RA) in patients undergoing reverse total shoulder replacement. Methods. This retrospective study included 15 patients with symptomatic rotator cuff arthropathy who underwent reverse total shoulder arthroplasty (rTSA) under ISB-RA without general anaesthesia in the beach chair position from 2010 to 2018. The mean patient age was 77 years (range 59–82 years). Patients had associated medical comorbidities: American Society of Anesthesiologists (ASA) grade 2–4. Assessed parameters were: duration of anaesthesia, intra-operative systolic blood pressure variation, sedation and vasopressor use, duration of post-operative recovery, recovery scores, length of stay, and complications. A robust cost analysis was also performed. Results. The mean (range) duration of anaesthesia was 38.66 (20–60) min. Maximum and minimum intra-operative systolic blood pressure ranges were 130–210 and 75–145 mmHg, respectively (mean [range] drop, 74.13 [33–125] mmHg). Mean (range) propofol dose was 1.74 (1–3.0) mg/kg/h. The Median (interquartile range) post-operative recovery time was 30 (20–50) min. The mean (range) postoperative recovery score (local scale, range 5–28 where lower values are superior) was 5.2 (5–8). The mean (range) length of stay was 8 (1–20 days); the two included patients with ASA grade 2 were both discharged within 24 hours. One patient with predisposing history developed pneumonia; however, there were no complications related to ISB-RA. The mean (range) cost per patient was £101.36 (£59.80-£132.20). Conclusions. Our data demonstrate that rTSA under ISB-RA is safe, cost-effective and a potentially viable alternative for patients with multiple comorbidities. Notably, patients with ASA grade 2 who underwent rTSA under ISB-RA had a reduced length of stay and were discharged within 24 hours


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 33 - 33
1 Nov 2021
García-Mansilla A Castro-Lalín A Holc F Molho N Vescovo A Slullitel P Buttaro M
Full Access

To compare the incidence of Bone Cement Implantation Syndrome (BCIS), perioperative thromboembolic events and mortality in patients with a femoral neck fracture (FNF) treated with a hybrid total hip arthroplasty (THA) without intraoperative unfractioned heparin (UFH) (control) versus a group of patients who received intraoperative UFH before femoral cementation. We retrospectively reviewed 273 patients who underwent hybrid THA due to a FNF between 2015 and 2020. We compared a group of 139 patients without intraoperative administration of UFH (group A) with 134 patients who underwent THA with intraoperative administration of 10 UI/kg UFH (group B). UFH indication was dependent on surgeon´s preference. We assessed the advent of BCIS and 30-day thromboembolic events, as well as 90-day and 1-year mortality. BCIS was observed in 51 cases (18%), defined as Grade 1 (O2% < 94% or fall in systolic blood pressure of 20% to 40%) in 37 cases (13%) and Grade 2 (O2% < 88% or fall in systolic blood pressure of > 40%) in 14 cases (5%). Forty-seven BCIS (35%) were observed in the group that received UFH and 4 BCIS (3%) in the control group (p <0.001). Multivariate regression model showed that intraoperative UFH (OR=18, CI95% 6–52) and consumption of oral anticoagulants (OR=3.3, CI95% 1–10) had an increased risk of developing BCIS. Five patients developed a pulmonary embolism in the UFH group while 2 patients presented this complication in the non UFH group (p=0.231). Mortality was 1% for both groups at 90 days PO (p= 0.98), 2% at 1 year for group A and 3% for group B (p =0.38). BCIS in our series was 18%. We found a paradoxically 17-fold significant increase of BCIS with the use of UFH. Heparin did not prevent BCIS, thromboembolic events and mortality in this group of patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 83 - 83
1 Jan 2016
Ko TS Jeong HJ Lee JH
Full Access

Purpose. The purposes of this study are as follows; 1) to compare postoperative blood loss between general anesthesia(GA) and spinal anesthesia(SA) and 2) to analyze the affecting factors of postoperative blood loss through the subgroup analysis. METHODS. A retrospective analysis was made on the clinical data of 122 patients with osteoarthritis undergoing primary TKA between January 2012 and December 2013. According to different anesthetic method, the patients were divided into the General Anesthesia group (73 cases) and the Spinal Anesthesia group (49 cases). Each group was divided subgroup as age, BMI, Preoperative blood pressure, Surgery time, Torniquet time, INR. The total blood loss, Post Operation 1 day blood loss, hidden blood loss, and the percentage of hidden blood loss were compared between 2 groups. For the analysis of postoperative blood loss, each group was compared postoperative blood loss using hemovac drainage per day and total blood loss. In preoperative blood pressure, Higher than 140 mmHg in systolic blood pressure and higher than 90 mmHg in diastolic blood pressure were employed as a cut-off value to group the well-controlled hypertension group(n=42) and uncontrolled hypertension group(n=29). RESULTS. One day after the surgery blood loss(p=0.322) and total blood loss(p=0.560) showed no significant differences between two group. But in the uncontrolled hypertension group showed a large amount of bleeding one day after the surgery(p=0.003) and total blood loss(p=0.004) in the spinal anesthesia. CONCLUSION. It seems that, general anesthesia is effective method to reduce postoperative blood loss. Preoperative blood pressure control is one of the important affecting factor of postoperative blood loss


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 27 - 27
1 Dec 2022
Suter T Old J McRae S Woodmass J Marsh J Dubberley J MacDonald PB
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 5 - 5
1 Dec 2022
McRae S Suter T Old J Zhang Y Woodmass J Marsh J Dubberley J MacDonald P
Full Access

Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 12 - 12
1 Dec 2022
Shadgan B Kwon B
Full Access

Despite advances in treating acute spinal cord injury (SCI), measures to mitigate permanent neurological deficits in affected patients are limited. Augmentation of mean arterial blood pressure (MAP) to promote blood flow and oxygen delivery to the injured cord is one of the only currently available treatment options to potentially improve neurological outcomes after acute spinal cord injury (SCI). However, to optimize such hemodynamic management, clinicians require a method to measure and monitor the physiological effects of these MAP alterations within the injured cord in real-time. To address this unmet clinical need, we developed a series of miniaturized optical sensors and a monitoring system based on multi-wavelength near-infrared spectroscopy (MW-NIRS) technique for direct transdural measurement and continuous monitoring of spinal cord hemodynamics and oxygenation in real-time. We conducted a feasibility study in a porcine model of acute SCI. We also completed two separate animal studies to examine the function of the sensor and validity of collected data in an acute experiment and a seven-day post-injury survival experiment. In our first animal experiment, nine Yorkshire pigs underwent a weight-drop T10 vertebral level contusion-compression injury and received episodes of ventilatory hypoxia and alterations in MAP. Spinal cord hemodynamics and oxygenation were monitored throughout by a transdural NIRS sensor prototype, as well as an invasive intraparenchymal (IP) sensor as a comparison. In a second experiment, we studied six Yucatan miniature pigs that underwent a T10 injury. Spinal cord oxygenation and hemodynamics parameters were continuously monitored by an improved NIRS sensor over a long period. Episodes of MAP alteration and hypoxia were performed acutely after injury and at two- and seven-days post-injury to simulate the types of hemodynamic changes patients experience after an acute SCI. All NIRS data were collected in real-time, recorded and analyzed in comparison with IP measures. Noninvasive NIRS parameters of tissue oxygenation were highly correlated with invasive IP measures of tissue oxygenation in both studies. In particular, during periods of hypoxia and MAP alterations, changes of NIRS-derived spinal cord tissue oxygenation percentage were significant and corresponded well with the changes in spinal cord oxygen partial pressures measured by the IP sensors (p < 0.05). Our studies indicate that a novel optical biosensor developed by our team can monitor real-time changes in spinal cord hemodynamics and oxygenation over the first seven days post-injury and can detect local tissue changes that are reflective of systemic hemodynamic changes. Our implantable spinal cord NIRS sensor is intended to help clinicians by providing real-time information about the effects of hemodynamic management on the injured spinal cord. Hence, our novel NIRS system has the near-term potential to impact clinical care and improve neurologic outcomes in acute SCI. To translate our studies from bench to bedside, we have developed an advanced clinical NIRS sensor that is ready to be implanted in the first cohort of acute SCI patients in 2022


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 53 - 53
1 Dec 2022
Sidhu A Kerr J Howard L Masri B McEwen J Neufeld M
Full Access

Tourniquet use in total knee arthroplasty (TKA) remains a subject of considerable debate. A recent study questioned the need for tourniquets based on associated risks. However, the study omitted analysis of crucial tourniquet-related parameters which have been demonstrated in numerous studies to be associated with safe tourniquet use and reduction of adverse events. The current utilization and preferences of tourniquet use in Canada remain unknown. Our primary aim was to determine the current practices, patterns of use, and opinions of tourniquet use in TKA among members of the Canadian Arthroplasty Society (CAS). Additionally, we sought to determine the need for updated best practice guidelines to inform optimal tourniquet use and to identify areas requiring further research. A self-administered survey was emailed to members of the CAS in October 2021(six-week period). The response rate was 57% (91/161). Skip logic branching was used to administer a maximum of 59 questions related to tourniquet use, beliefs, and practices. All respondents were staff surgeons and 88% were arthroplasty fellowship trained. Sixty-five percent have been in practice for ≥11 years and only 16% for 50 TKA/year, 59% have an academic practice, and >67% prefer cemented TKA. Sixty-six percent currently use tourniquets, 25% no longer do but previously did, and 9% never used tourniquets. For those not using tourniquets, the most common reasons are potential harm/risks and publications/conferences. Among current users, 48% use in all cases and an additional 37% use in 76-99% of cases. The top reason for use was improved visualization/bloodless field (88%), followed by performing a cemented TKA, used in training, and faster operative times. The main patient factor influencing selective tourniquet use was peripheral vascular disease and main surgical factors were operative duration and cementless TKA. The most frequent adverse events reported were bruising/pinching under the tourniquet and short-term pain, which majority believed were related to improper tourniquet use (prolonged time, high-pressures, poor cuff fit), yet only 8% use contoured tourniquets and 32% don't use limb protection. Despite substantial evidence in literature that tourniquet safety and probability of harm are affected by tourniquet time and pressure, only 83% and 72% of respondents believe reducing tourniquet time and pressure respectively reduce the probability of harm. In addition, no surgeon utilizes personalized limb occlusion pressure which has been demonstrated to substantially reduce tourniquet pressure while being safe and effective. Furthermore, 62% always use fixed pressure and 37% will modify the pressure based on patient parameters, most often systolic blood pressure and limb size. Almost all (88%) were interested in new evidence-based guidelines regarding these parameters. Tourniquet use in TKA remains prevalent among arthroplasty surgeons in the CAS; however tremendous practice variability regarding several key parameters required for optimal use exists. Current best practices of tourniquet use regarding personalized pressures, time, and type are not being utilized across Canada. There is considerable interest and need for further research and updated guidelines regarding key parameters of safe tourniquet usage to optimize tourniquet use in TKA


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 109 - 109
1 Mar 2009
Hadjipavlou A Tzermiadianos M Katonis P Gaitanis I Paskou D Kakavelakis K Patwardhan A
Full Access

The circulatory effects of multilevel balloon kyphoplasty (BK) are not adequately addressed, neither the effectiveness of egg shell cementoplasty in preventing anticipated cement leakage in difficult cases. The purpose of this study was to evaluate. the effect of multilevel BK to blood pressure and arterial blood gasses;. the incidence of methylmethacrylate cement leakage using routine postoperative computer tomography scan and. the effectiveness of egg shell cementoplasty to prevent cement leaks. Materials and methods: This is a prospective study of 89 patients (215 vertebral bodies-VBs) with osteoporotic compressive fractures (OCF), and 27 with osteolytic tumors (OT) (88 VBs). The mean age was 67.6 years. 27 patients with OCF were treated at one level, 26 at two, 21 at three, 7 at four, 6 at five, and 2 at six levels at the same sitting. Three patients with OT were treated at one level, 6 at two, 9 at three, 3 at four, 4 at five, and 2 at seven. Egg shell balloon cementoplasty to prevent cement leakage was performed in 10 patients with severe endplate fracture or vertebral wall lytic destruction. Arterial blood pressure and oxygen saturation were monitored during surgery. Arterial blood gases were measured before and 3 min after cement injection. Cement leakage was assessed by the postoperative x rays and computer tomography scans. Results: A drop in blood pressure of more than 25mmHg during cement injection was observed in 6 patients, and was not associated with the number of VB treated. Blood pressure was dropped more than 40mm in 2 patients and the procedure was aborted after completing 1 level in the first and 2 levels in the second. Drop in arterial O2 saturation was noted in 4 patients. One patient treated for 5 levels developed fever and tachepnoea for 24 hours after surgery. Arterial O2 and chest x-rays were normal. Cement leakage was found in 9.7% (21/215) of VBs treated for OCF. Its incidence per location was: epidural, 0.9% (2 VBs); intraforaminal, 0.5% (1 VB); intradiscal, 3.2% (7 VBs); and through anterior or lateral walls, 5.1% (11 VBs). In the OT group cement leakage was found in 10.2% (9/88) of the treated VBs. Its location included 8 (9%) through the anterior or lateral walls and one (1.1%) intradiscal. Cement leakage had no clinical consequences. No cement leakage was observed in cases treated with egg shell balloon cementoplasty. Conclusions: BK is a safe procedure when applied for multiple levels in the same sitting, and its rare circulatory effects are not related to the number of levels treated. The incidence of cement leakage in this study was 10%, which is far less than that reported with vertebroplasty using routine postoperative CT scan. Egg shell balloon cementoplasty can effectively minimize cement leakage in cases with fractured endplate or lytic destruction of VB walls


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 53 - 53
1 Apr 2017
Goubran A McHale S Steinlechner C
Full Access

Background. Aseptic loosening of cemented femoral stems results from migration of wear particles along the bone-cement interface, producing a foreign body reaction. After cement insertion, blood back pressure can disrupt the bone-cement interface, enabling this spread of wear particles. Our study investigates whether altering timing and speed of stem insertion can reduce this risk. Methods. We inserted mock “C-Stem” femoral components (De Puy-Synthes), using Smartset HV cement (De Puy-Synthes) into artificial femora, fitted with proximal and distal pressure transducers. Cement insertion began two, three or four minutes after mixing. Cement pressures were then allowed to settle for one minute and the stems were then inserted over durations of 25, 60 or 90 seconds. Results. Quicker insertion led to high peak pressures; however insertion over 90 seconds at 4 and 5 minutes achieved more sustained pressures above blood back pressure. Slower insertion particularly improved proximal pressurisation. Furthermore when the stem was inserted over 90 seconds at 5 minutes then the cement pressures remained high after full insertion of the stem. Conclusions. Commonly, femoral stems are inserted rapidly. Our study demonstrates that by inserting the femoral stem more slowly, cement pressure can be maintained above blood back pressure for longer. We believe that after slower stem insertion, the higher cement viscosity enables the surgeon to maintain cement pressure, via the stem, sufficient to resist blood back pressure without inadvertently over inserting the stem. This safe and simple modification of cementing technique generates higher and more sustained cement pressures. Level of evidence. 3. Disclosures. Depuy-Synthes kindly provided the equipment used in the study. None of the authors received any payment or other benefits


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 105 - 105
1 May 2011
Daglar B Bayrakci K Delialioglu O Tezel K Gunel U
Full Access

Introduction: Compartment syndrome is one of the most devastating complications in orthopaedic trauma cases. The aim of this study is to investigate whether the intra-compartmental pressure changes rise and stay above the dangerous limits during percutaneous bridge plating of tibial shaft fractures necessitating fascial release or not. Patients and Methods: Between January 2007 and April 2009 17 isolated tibial fractures of the 17 patients were treated with percutaneous bridge plating technique by a single orthopaedic trauma surgeon. During the operation before, during and after the plating leg compartmental pressures were measured by using invasive blood pressure monitor. Demographic, trauma and fracture related data were also recorded. Analyses were performed by using SPSS 13. Findings: Mean age was 32 (19–55) years. Mean of ISS was 14 (10–27). Plating was performed at a mean of 3,3 (1–6) days after the trauma. Means of difference between systolic and diastolic blood pressure and leg anterior compartment pressures just before the plate insertion were 42 and 25,5 (16–32) mmHg respectively. During plating compartmental pressures rose to a mean of 51,5 mmHg (p=0,001) and dropped to 50 mmHg 10 minutes after implantation. Mean delta P was – 7 mmHg for the leg antertior compartment ten minutes after plating. No correlation was found between the blood pressure differences; ISS; age; type of anesthesia and delta P (r< 0,1 and p> 0,05). Although there is a trend of having decreased delta P with earlier surgery difference was not significant (r=0,18; p=0,058). Conclusion: Anterolateral percutaneous bridge plating of tibial shaft fractures significantly increases intracom-partmental pressures. Physician should carefully judge the risk of compartment syndrome in each patient separately and should not hesitate to perform percutaneous fascial release intraoperatively


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 24 - 24
1 Mar 2009
Tötterman A Madsen J Skaga N Röise O
Full Access

Objective: To assess the impact of EPP on physiological parameters in hemodynamically unstable patients with blunt pelvic trauma. Methods: Of 661 patients treated for pelvic trauma, 18 consecutive patients in shock underwent EPP with the intent to control massive pelvic bleeding. These patients constituted the study population. Data collected from the medical records and the Ullev̊l Trauma Registry included: demographics, fracture classification, additional injuries, blood transfusions, surgical interventions, angiographic procedure, physiological parameters and outcome. An association between continuous variables was calculated using the Spearman correlation coefficient. A comparison between means was calculated using the t-test. Results: Mean patient age was 44 years (range 16–80). ISS 47 (9–66). 39 % had non-measurable blood pressure at admission. Survival rate within 30 days was 72% (13/18) and correlated inversely to the age of the patient (p=0.038). Only one non-survivor died of exsanguination from multiple bleeding foci. A significant increase in systolic blood pressure (p=0.002) and hemoglobin count (p=0.012) was observed immediately after EPP. Arterial injury was observed in 80% of patients who underwent angiography after EPP. Conclusions: 30-day survival rate after EPP was 72 %. A significant increase in systolic blood pressure and hemoglobin count was observed immediately after EPP, indicating that EPP as part of a multi-interventional resuscitation protocol may be life-saving in patients with exsanguinating pelvic injury. However, the high rate of arterial injuries seen after EPP indicates that the procedure should be supplemented with angiography once the patient is stabilized for transfer to the angiography suite


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 323 - 323
1 Mar 2013
Seki T Hasegawa Y Matsuoka A Ishiguro N
Full Access

Background. One-stage bilateral total hip arthroplasty (THA) is twice as invasive as unilateral THA. Therefore, increases in bleeding, postoperative anemia, and complications are a concern. The purpose of this study was to investigate hemoglobin values and the use of autologous and allogenic blood transfusion after one-stage bilateral THA. Methods. Twenty-nine patients (7 men and 22 women; 58 hips) were treated with one-stage bilateral THA. The mean age of subjects at the time of surgery was 60.6 years. The average body mass index for patients was 21.7 kg/m. 2. The diagnoses were secondary osteoarthritis due to developmental dysplasia of the hip (n=25) and avascular necrosis (n=4). All patients had donated 800 ml of autologous blood in 2 stages preoperatively (1 to 4 weeks apart). All patients took iron supplements starting from 5 weeks preoperatively. For all patients, the procedure was performed under general anesthesia in the lateral decubitus position via a posterolateral approach. Intra-operative blood salvage was not used. Suction drains were inserted subfascially. As a general rule, pre-donated autologous blood was transfused back to the patients intra- or post-operatively. Allogenic blood transfusion was performed when clinical symptoms of anemia occurred (hypotension, low urinary output, tachycardia, etc.) rather than using a preset blood threshold (hemoglobin level <8 g/dl). To determine changes in blood pressure following surgery until the next morning, systolic and diastolic blood pressure were measured at 3-hr intervals. Results. The mean duration of surgery was 67.4 min for the procedure on the side that was operated on first, 32.7 min to change to the other side, and 68.4 min for the procedure on the other side. The mean blood loss was 576.1 ml. Hemoglobin values at baseline, at the time of autologous blood donation, and on the first day after surgery were 13.2, 12.7, and 8.7 g/dl respectively. Hemoglobin values were significantly different between the 2 weeks before surgery and the first day after surgery. Systolic and diastolic blood pressure were the lowest 3–6 hrs postoperatively (mean, 86/55). Blood reinfusion using autologous blood was performed for all patients. The allogenic blood transfusion rate was 25.0% (range, 2–8 units). In terms of complications, one patient developed an arrhythmia on postoperative day 5. This was the patient for whom autologous blood donation could not be performed due to pre-existing anemia. This patient also had right-sided sciatic nerve palsy. Discussion. With respect to one-stage bilateral THA, Gie showed that allogenic blood transfusion rate with or without autologous blood donation was 42% and 87% respectively. The allogenic blood transfusion rate was 25.0% in our study. Establishing a procedure to perform surgery in a shorter time period may further reduce the rate of allogenic blood transfusion. Although not used herein, intraoperative blood salvage may also be considered. Conclusions. In one-stage bilateral THA, autologous blood donation is effective in managing perioperative anemia and reducing the rate of allogenic blood transfusion. Perioperative blood management based on individual patients' situations are important for the safe performance of one-stage bilateral THA


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 287 - 288
1 Mar 2003
Aebli N Krebs J Davis G Goss B Theis J
Full Access

INTRODUCTION: Vertebroplasty (VP) is a new prophylactic treatment for preventing osteoporotic compression fractures of vertebral bodies. During this procedure polymethylmethacrylate (PMMA) is injected into several vertebral bodies. It has been shown that fat embolism (FE) with acute cardiopulmonary deterioration occurs during VP as in a variety of other orthopaedic procedures (eg knee and hip replacements). The aim of the study is to investigate cardiovascular changes during FE caused by multiple VP using an animal model. METHOD: In six sheep, PMMA was injected unilaterally, into L1 – L6, with ten minutes in between injections. Arterial, venous and pulmonary artery pressure, cardiac output and blood gas values were recorded pre injection and one, three, five and 10 minutes post injection. Post mortem lungs were harvested and the histopathologic score (percentage of lung fields occupied by intravascular fat globules as seen in the microscope) was calculated. RESULTS: The sequential injection of bone cement into six vertebral bodies from values pre injection of L1 to 10 minutes post injection of L6 resulted in: significant falls in arterial blood pressure (P< 0.0001), cardiac output (P=0.0049), pO2 (P< 0.0001) and pH (P< 0.0001) and significant rises in pulmonary arterial pressure (P=0.0005) and pCO2 (P< 0.0001), but no significant change in central venous pressure. The histopathological score was 19.1±1.94%. CONCLUSION: This study clearly shows that multiple VP in sheep leads to FE with major cardiovascular reactions. Arterial blood pressure showed a stepwise, cumulative fall and was clearly the best parameter to demonstrate these reactions. This suggests, in human patients, particular attention should be paid to falls in arterial blood pressure during multiple VP


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 92 - 92
1 Jan 2004
Aebli N Krebs J Davis G Goss B Theis J
Full Access

Introduction: Vertebroplasty (VP) is a new prophylactic treatment for preventing osteoporotic compression fractures of vertebral bodies. During this procedure polymethylmethacrylate (PMMA) is injected into several vertebral bodies. It has been shown that fat embolism (FE) with acute cardiopulmonary deterioration occurs during VP as in a variety of other orthopaedic procedures (e.g. knee and hip replacements). The aim of the study is to investigate cardiovascular changes during FE caused by multiple VP using an animal model. Method: In six sheep, PMMA was injected unilaterally, into L1 – L6, with ten minutes in-between injections. Arterial, venous and pulmonary artery pressure, cardiac output and blood gas values were recorded pre injection and 1, 3, 5 and 10 minutes post injection. Post mortem lungs were harvested and the histopathologic score (percentage of lung fields occupied by intravascular fat globules as seen in the microscope) was calculated. Results: The sequential injection of bone cement into six vertebral bodies from values pre injection of L1 to 10 minutes post injection of L6 resulted in: significant falls in arterial blood pressure (P< 0.0001), cardiac output (P< 0.0001) (P=0.0049), pO. 2. and pH (P< 0.0001) and significant rises in pulmonary arterial pressure (P=0.0005) and pCO. 2. (P< 0.0001),but no significant change in central venous pressure. The histopathological score was 19.1±1.94%. Conclusion: This study clearly shows that multiple VP in sheep leads to FE with major cardiovascular reactions. Arterial blood pressure showed a stepwise, cumulative fall and was clearly the best parameter to demonstrate these reactions. This suggests, in human patients, particular attention should be paid to falls in arterial blood pressure during multiple VP