The purpose of this study was to evaluate outcome following arthroscopic
Management of the pathologic long-head biceps tendon remains controversial.
There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength.Introduction and Objective
Materials and Methods
Study design: Retrospective study of 34 patients with a massive rotator cuff tear, who were treated with an arthroscopic tuberoplasty, debridement of the degenerate cuff and
The functional importance of the long head of biceps tendon remains controversial, but it is well accepted as an important source of anterior shoulder pain. Both
The long head of the biceps tendon has been proposed as a source of pain in patients with rotator cuff tears. The purpose of this study is to evaluate the objective, subjective, and radiographic results of arthroscopic
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic
Introduction: A cosmetic deformity does not always occur after a
Introduction. Superior Labral Anterior Posterior Tears are being treated surgically in increasing numbers. Stiffness is the most common complication. We reviewed 115 cases of SLAP repairs to try and identify preoperative risk factors if any for stiffness. Methods. Retrospective cohort study of 115 patients who underwent SLAP repair. All patients failed attempts at conservative therapy including NSAIDS, Physical Therapy and cortisone injections. Results. Age ranged from 16–71 years, with an average age of 46. Male 84, Female 31. patient charts and operative notes were examined from 2004–2009. We used an average of 1.64 anchors per case; we performed arthroscopic Mumford on 15 patients, subscap repair (4), 19 cases with concomitant SLAP repair and Arthroscopic rotator cuff repair Other procedures included
Purpose: Arthroscopic arthroplasty for painful shoulder is not always successful. Repeated arthroscopy is sometimes discussed for patients with recurrent pain. The purpose of this work was to determine the technique and identify indications. Material and methods: We conducted a retrospective analysis of 24 patients (13 men, 11 women), mean age 52 years, who underwent repeated arthroscopy after failure within 31 months of arthroscopic acromioplasty with no other intervention. Three groups were formed: group 1 (7 patients): subacromial impingement due to tendinitis with intact supraspinatus; group 2 (11 patients): subacromial impingement secondary to cuff tear; group 3 (6 patients): calcified tendinopathy. In group 1, the acromion was type 1 in three cases, type 2 in three and type 3 in one; repeated arthroscopy included complementary acromioplasty. In group 2, all patients had complementary acromioplasty; six of them with
Purpose: The purpose of this study was to assess long-term functional outcome after arthroscopic acromioplasty for full-thickness rotator cuff tears, to evaluate the efficacy of complementary procedures (biceps tenotomy, extended acromioclavicular resection), and to examine the course of anatomic lesions. Material and methods: From 1988 to 1994, 141 full-thickness rotator cuff tears were treated by arthroscopic acromioplasty. Ninety-eight patients, mean age 60 years, were reviewed clinically, radiographically, and sonographically at more than eight years. The mean preoperative Constant score was 48.5 points. The tear involved the supraspinatus in 18 cases, the supraspinatus and infraspinatus in 40, the supraspinatus and the subscapularis in ten, and all three tendons in 20. Coronal extension showed a distal tear in four, an intermediate tear in 52, and a retracted stump in 32. Systemic acromioplasty was associated in 36 patients with tenotomy of the long head of the brachial biceps and in 44 with acromioclavicular extension. Results: At mean follow-up of 10.7 years (8–13.5), the mean Constant score was 60 points. The clinical outcome was excellent or good in 39.7%, fair in 45.5%, and poor in 14.8. 62.5% of the patients were satisfied or very satisfied. The height of the subacromial space was 5.19 mm at last follow-up compared with 4.3 mm preoperatively. The antalgesic effect of
Glenohumeral osteoarthritis (OA) is a challenging clinical problem in young patients. Given the possibility of early glenoid component loosening in this population with total shoulder arthroplasty (TSA), and subsequent need for early revision, alternative treatment options are often recommended to provide pain relief and improved range of motion. While nonoperative modalities including nonsteroidal anti-inflammatory medications and physical therapy focusing on rotator cuff strengthening and scapular stabilization may provide some symptomatic relief, young patients with glenohumeral OA often need surgery for improved outcomes. Joint preserving techniques, such as arthroscopic debridement with removal of loose bodies and capsular release, with or without
The diagnosis and treatment of disorders of the long head of the biceps tendon remains controversial. There is uncertainty as to the role of the long head of biceps and it can be difficult to determine whether the patient's pathology is coming from the biceps or other adjacent structures. In addition, the appropriate type of treatment remains controversial. We retrospectively reviewed the files of the senior author's experience in over 4000 arthroscopic shoulder procedures. We examined cases involving isolated biceps pathology, excluding those patients with rotator cuff tears and labral pathology, involving 92
The results of arthroscopic repair of tears of the sub-scapularis tendon in nine men and six women, ranging in age from 53 to 73 years, were followed up at a mean of 14 months (6 to 24). Three were complete tears, six 50%-tears and six 30%-tears. In seven patients there were associated tears of the supraspinatus and infraspinatus tendons, which were repaired arthroscopically during the same procedure. In each case the subscapularis tear was identified. In most patients a
Purpose: The objective of this study was to analyze the clinical results of arthroscopic release for the treatment of shoulder stiffness and to report the results according to etiology. Method: Thirty cases were reviewed in 29 patients with a mean age of 48 years [range, 25–75]. The mean time from diagnosis to surgery was 37.5 months [range, 6–120]. The stiffness was considered idiopathic (i.e. frozen shoulder) (10 cases), post-traumatic (eight cases) or post-surgical (12 cases). The release consisted of 14 rotator interval resections, four anterior capsulotomies, 20 anterior and inferior capsulotomies, three tenotomies of the superior portion of the subscapularis, and 11
Introduction. The purpose of this study was to assess the rate of revision subacromial decompression and identify different pathologies. Materials/Methods. We analysed the patients who underwent Revision Arthroscopic Subacromial decompression from our prospective database of shoulder patients. Between April 2003 and Dec 2010, 797 patients underwent arthroscopic subacromial decompression. Patients who underwent any other procedure i.e.
Aims: We reviewed our experience to determine the results of arthroscopic repair in patients over 50 with rotator cuff tears and Type II SLAP lesion in whom the repair was effected repairing the two lesions, or repairing the rotator cuff tears and performing a tenotomy of the long head of the biceps. Methods: We recruited 121 patients older than 50 years in whom a symptomatic rotator cuff tear had failed non-surgical management and was affecting daily activities. We assigned them retrospectively to one of the two groups: Group 1 underwent arthroscopic repair of the rotator cuff and repair of the type II SLAP lesion. Group 2 underwent arthoscopic repair of the rotator cuff tear and a tenotomy of the long head of the biceps. Results: There was statistically significant difference in total postoperative UCLA scores and ROM when comparing the two groups postoperatively (P<
0.05). Conclusions: We compared the clinical outcome of patients over 50 affected by the association of rotator cuff tears and Type II SLAP lesion, in whom both the defects were repaired, or the rotator cuff tear was repaired and the long head of the biceps tendon was tenotomized. In our hands, the association of rotator cuff repair and
Background: Rotator cuff tears involving the subscapularis are less common than those involving the posterior superior rotator cuff. The purpose of this study is to report the results of repair of isolated tears of the subscapularis. Methods: Eighty-four shoulders that had undergone open repair of the subscapularis tendon were reviewed. The mean age at surgery was 53.2 years. The mean interval from onset of symptoms to surgery was 12.5 months. Fifty-seven tears were traumatic, and twenty-seven were degenerative in etiology. Twenty-three of the tears involved the superior third of the subscapularis tendon, forty-one involved the superior two thirds, and twenty were complete tears. Fifty-four shoulders had a dislocation or subluxation of the long head of the biceps tendon, while ten shoulders had a rupture of the long head of the biceps tendon. Forty-eight shoulders underwent concomitant biceps tenodesis; thirteen shoulders underwent concomitant
Massive irreparable rotator cuff tears (MIRCTs) represent a difficult situation especially in painful and pseudoparalytic patients. A new technique, consisting of an arthroscopic implantation of an inflatable biodegradable “balloon”, serving as a temporary subacromial spacer, has been introduced recently for MIRCTs. The purpose of this paper is: 1) to present the efficacy and safety results of patients treated with the balloon; 2) to show that these results are maintained over time, after balloon degradation; 3) to compare these results to published results of other procedures available for MIRCTs. This paper presents the first group of 22 patients (females/males 13/8, one bilateral), treated in a single-surgeon, prospective and on-going series of 97 shoulders operated with the balloon, since September 2010. The mean age is 69.3 (52–86) and the average follow-up 52.5 months. The balloon is inserted arthroscopically and inflated with saline. The procedure is simple with a short operative time (10–20 min). It can also supplement partial repairs, especially of the subscapularis, as well as repairable massive tears with bad tissue quality. The balloon is not used in severe cuff tear arthropathy or complete insufficiency of the external rotators. Final outcome scores, Constant (CS) and UCLA scores are obtained at least three years after complete balloon degradation (which occurs within 12 months), and are also compared to those of other treatments available for MIRCTs. No device related safety issues were observed in this group. Good results, including rapid pain relief and restoration of active motion, which maintained over time, are obtained in 85% of the patients. The CS has improved significantly (average preop/postop: pain 2.9/12.7; ADL 6.8/17.4; ROM 22.8/36.6; strength 3.1/5.6; TOTAL 35.8/72.3; NORMATIVE 42.7/86.4). The UCLA score has also improved significantly (preop/postop: pain 1.9/8.6; function 3.9/8.6; active flexion 3.5/4.5; strength in flexion 2.4/3.4; satisfaction 0/4.5; TOTAL 11.2/29.8). Pseudoparalysis is reversed (average preop/postop flexion 86°/156.8°). The CS and UCLA score for the balloon are superior compared to published results of debridement,