header advert
Results 1 - 20 of 83
Results per page:
Bone & Joint Open
Vol. 5, Issue 1 | Pages 28 - 36
18 Jan 2024
Selmene MA Moreau PE Zaraa M Upex P Jouffroy P Riouallon G

Aims. Post-traumatic periprosthetic acetabular fractures are rare but serious. Few studies carried out on small cohorts have reported them in the literature. The aim of this work is to describe the specific characteristics of post-traumatic periprosthetic acetabular fractures, and the outcome of their surgical treatment in terms of function and complications. Methods. Patients with this type of fracture were identified retrospectively over a period of six years (January 2016 to December 2021). The following data were collected: demographic characteristics, date of insertion of the prosthesis, details of the intervention, date of the trauma, characteristics of the fracture, and type of treatment. Functional results were assessed with the Harris Hip Score (HHS). Data concerning complications of treatment were collected. Results. Our series included 20 patients, with a mean age of 77 years (46 to 90). All the patients had at least one comorbid condition. Radiographs showed that 75% of the fractures were pure transverse fractures, and a transverse component was present in 90% of patients. All our patients underwent surgical treatment: open reduction and internal fixation, revision of the acetabular component, or both. Mean follow-up was 24 months, and HHS at last follow-up was 75.5 (42 to 95). The principal complications observed were dislocations of the prosthesis (30%) and infections (20%). A need for revision surgery was noted in 30% of patients. No dislocation occurred in patients undergoing osteosynthesis with acetabular reconstruction. We did not note either mechanical loosening of the acetabular component nor thromboembolic complications. In all, 30% of patients presented acute anemia requiring transfusion, and one death was reported. Conclusion. Post-traumatic periprosthetic acetabular fractures frequently have a transverse component that can destabilize the acetabular implant. The frequency of complications, principally dislocations, led to a high rate of revision surgery. Improvements in preoperative planning should make it possible to codify management to reduce this high rate of complications. The best results were obtained when the surgical strategy combined osteosynthesis with acetabular reconstruction. Cite this article: Bone Jt Open 2024;5(1):28–36


Bone & Joint Open
Vol. 5, Issue 8 | Pages 652 - 661
8 Aug 2024
Taha R Davis T Montgomery A Karantana A

Aims. The aims of this study were to describe the epidemiology of metacarpal shaft fractures (MSFs), assess variation in treatment and complications following standard care, document hospital resource use, and explore factors associated with treatment modality. Methods. A multicentre, cross-sectional retrospective study of MSFs at six centres in the UK. We collected and analyzed healthcare records, operative notes, and radiographs of adults presenting within ten days of a MSF affecting the second to fifth metacarpal between 1 August 2016 and 31 July 2017. Total emergency department (ED) attendances were used to estimate prevalence. Results. A total of 793 patients (75% male, 25% female) with 897 MSFs were included, comprising 0.1% of 837,212 ED attendances. The annual incidence of MSF was 40 per 100,000. The median age was 27 years (IQR 21 to 41); the highest incidence was in men aged 16 to 24 years. Transverse fractures were the most common. Over 80% of all fractures were treated non-surgically, with variation across centres. Overall, 12 types of non-surgical and six types of surgical treatment were used. Fracture pattern, complexity, displacement, and age determined choice of treatment. Patients who were treated surgically required more radiographs and longer radiological and outpatient follow-up, and were more likely to be referred for therapy. Complications occurred in 5% of patients (39/793). Most patients attended planned follow-up, with 20% (160/783) failing to attend at least one or more clinic appointments. Conclusion. MSFs are common hand injuries among young, working (economically active) men, but there is considerable heterogeneity in treatment, rehabilitation, and resource use. They are a burden on healthcare resources and society, thus further research is needed to optimize treatment. Cite this article: Bone Jt Open 2024;5(8):652–661


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 39 - 39
1 Dec 2014
Maqungo S Kimani M Chhiba D McCollum G Roche S
Full Access

Purpose of study:. The presence of an L5 transverse process fracture is reported in many texts to be a marker of pelvis fracture instability. There is paucity of literature to support this view. Available studies have been performed on patients who were already known to have a pelvis fracture. No study has attempted to document the presence of this lesion in the absence of a pelvis fracture. Primary aim: To identify the correlation between the presence of a L5 transverse process fracture and an unstable pelvic ring injury. Secondary aim: To establish whether a L5 transverse process fracture can occur in the absence of a pelvis fracture. Methods:. We conducted a retrospective review of all CT scans performed in patients who presented to a Level 1 Trauma Unit for blunt abdomino-pelvic trauma between January 1, 2012 and August 28, 2013. A total of 203 patients met our inclusion criteria. Results:. Fifty four of these 203 patients (26%) sustained a pelvis fracture. Of these 54 patients 26 (48%) had an unstable fracture pattern according to the AO classification. Five of these 26 patients (19%) had an associated L5 transverse process fracture. Seven (12%) had an L5 transverse process fracture associated with a stable fracture pattern. Three patients (1.4%) had an isolated L5 transverse process fracture in the absence of a pelvis fracture. Conclusion:. This study confirms the association between the presence of a L5 transverse process fracture and an unstable pelvis fracture pattern. This injury is rarely seen in the absence of a pelvis fracture so its presence should alert the treating clinicians to the existence of a pelvis fracture


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 28 - 28
1 Dec 2020
Tekin SB Karslı B Kurt V Öğümsöğütlü E
Full Access

Evidence that L5 transverse process fracture indicates pelvic instability is insufficient and controversial. Because of unstable pelvis fractures have high mortality rate, they require urgent treatment and good follow-up. The lumbar region is also affected by high-energy traumas in the pelvis region, which causes damage to the muscles and ligamentous structures that adhere to the lumbar transverse process. For this reason, L5 transverse process fracture is thought to be an indicator showing pelvic instability. However, our study shows that this is not like that. This study was carried out in order to investigate the effect of L5 transvers process fracture on pelvic instability and lack of sufficient data in the literature. Between 2017–2020, 86 Patient who were hospitalized and treated with a diagnosis of pelvic fracture were retrospectively studied in our clinic. Pelvic X-Ray and tomography was taken pre-op for all patient. Demographic features, pre-op and post-op hemoglobin counts, how many units of blood transfusion needed in total, fixation method, surgical intervention, presence of additional injury, mechanism of injury for all patient were analyzed and the patients were categorized by investigating L5 transvers process fracture in their tomography. Fractures of patients were classified according toTyle classification. The patients were divided into two main groups as who stabil and unstabil pelvic fractures and L5 transvers process fracture and without. On stabil pelvic fractures and unstabil pelvic fractures, in term of instability effects of L5 transvers process fractures and those without were investigated. Also, changes in preop and post op hemoglaobin counts were investigated in pelvis with and without L5 transvers process fractures. With these, in terms of blood transfusion need the patients were evaluated whether there was a difference between those with L5 transvers process fractures and who did not. Again, whether the blood transfusion was statistically different in stable and unstable pelvis fractures was among the parameters looked at. In statistical analysis, no correlation was found between pelvic instability and L5 transvers process fracture. (p=0,933) No statistically significant difference was found in the evalution of blood transfusion between those with and without L5 transvers process fractures. (P=0,409)When the same parameter was evaluated in terms of stability and instability of the pelvis, it was seen that stability did not significantly affect the need for blood transfusion. (P=0,989) Pre-op and post-op hemoglobin changes of the patients who with L5 transvers process fracture and without were also analized. İn the analysis performed, there was no significant difference in patients with and without L5 transvers process fractures on pre-op and post-op hemoglobin values. (p=0.771/p=0.118)However, Postoperative hemoglobin values were significanly lower in patient with L5 transvers process fracture compared to preopetative hemoglobin values. (p=0.001). L5 transvers process fracture is not a parameter to showing pelvic instability. Stabil and unstabil fractures did not change the need for blood transfusion. The literatüre still needs much more study on this topic


Aims. Compression and absolute stability are important in intra-articular fractures such as transverse olecranon fractures. This biomechanical study aims to compare tension band wiring (TBW) with plate fixation by measuring compression within the fracture. Methods. A cross-over design and synthetic ulna models were used to reduce variation between samples. Identical transverse fractures were created using a 0.5mm saw blade and cutting jig. A Tekscan(tm) force transducer was calibrated and placed within the fracture gap. Twenty TBW or Acumed(tm) plate fixations were performed according to the recommended technique. Compression was measured while the constructs were static and during simulated elbow range of movement exercises. Dynamic testing was performed using a custom jig reproducing cyclical triceps contraction of 20N and reciprocal brachialis contraction of 10N. Both fixation methods were tested on each sample. Half were randomly allocated to TBW first and half to plating first. Data was recorded using F-scan (v 5.72) and analysed using SPSS(tm) (v 16). Paired T-tests compared overall compression and compression at the articular side of the fracture. Results. The mean overall compression for plating was 819N (+/− 602N 95%CI), TBW overall compression: 77N (+/−19N 95%CI) (P=0.039). Articular side compression for plating: 343N (+/− 276N 95%CI), TBW: 1N (+/− 2N 95%CI). (P=0.038). During simulated movements, overall compression reduced in both groups: TBW -14N (+/−7N) Plating -173N (+/−32N) and no increase in articular side compression was detected in the TBW group. Conclusion. Precontoured plates such as the Acumed(tm) olecranon system can provide significantly greater compression, compared to TBW in transverse olecranon fractures. This was significant for compression over the whole fracture surface and specifically at the articular side of the fracture. Also, in TBW, overall compression reduced and articular side compression remained negligible during simulated triceps contraction, challenging the tension band principle


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 10 - 10
8 Feb 2024
Powell-Bowns MFR Martin D Bowley A Moran M Clement ND Scott CEH
Full Access

Aim of this study was to identify reoperation rates in patients with short oblique and transverse fractures around a well fixed cemented polished taper slip stem and to determine any associations with treatment failure. Retrospective cohort study of 31 patients with AO transverse or short oblique Vancouver B1 PFFs around THA (total hip arthroplasty) cemented taper slip stems: 12 male (39%); mean age 74±11.9 (range 44–91); mean BMI 28.5±1.4 (range 16–48); and median ASA 3. Patient journeys were assessed, re-interventions reviewed. The primary outcome measure was reoperation. Time from primary THA to fracture was 11.3±7.8yrs (0.5–26yrs). Primary surgical management was fixation in 27/31 and rTHA (revision total hip arthroplasty) in 4/31. 10 of 31 (32%) patients required reoperation, 9 within 2 years of fracture: 1 following rTHA and 8 following ORIF. The commonest mode of failure was non-union (n=6). No significant associations with reoperation requirement were identified. Kaplan-Meier free from reoperation was 67.4% (49.8–85.0 95% CI) at 2 years and this was unaffected by initial management with ORIF or rTHA (Log rank 0.898). Of those reoperated, 6/10 required multiple reoperations to obtain either bony union or a stable revision construct and 13% ultimately required proximal femoral endoprostheses. The relative risk of 1 year mortality was 1.6 (0.25 to 10.1 95%CI) among patients who required reoperation compared to those who did not. These are difficult fractures to manage, should not be underestimated and patients should be counselled that there is a 30% risk of reoperation and 20% of requiring multiple reoperations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 8 - 8
13 Mar 2023
Powell-Bowns M Oag E Martin D Moran M Scott C
Full Access

The aim of the study was to report the survival of open reduction and internal fixation (ORIF) of Vancouver B fractures associated with the Exeter Stem (ES) at a minimum of 5 years. This retrospective cohort study assessed 129 consecutive patients with Vancouver B type fractures treated with ORIF from 2008-2016 at a minimum of 5 years. Patient records were examined, and the following recorded: details of primary prosthesis, details of injury, Vancouver classification, details of operative management, complications, and requirement for reoperation. Data was analysed using SPSS. Survival analysis was undertaken using the endpoint ‘reoperation for any reason’. Mean age at fracture was 78.2 (SD10.6, 46-96) and 54 (43%) were female. Vancouver subclassifications were: 24% B1, 70.5% B2 and 5.5% B3. For all Vancouver B fractures, Kaplan Meier analysis demonstrated a 5 year survival free from reoperation of 88.8% (82.0-94.7 95%CI). Fourteen patients required reoperation, most commonly within the first year for non-union and plate fracture (5.4%). Five-year survival for any reoperation differed significantly according to fracture type (p=0.016) and was worst in B1s: B1 76.6% (61.3-91.9); B2 92.6% 986.9-98.3); and 100% of B3. Univariate analysis identified B1 type (p=0.008) and a transverse fracture pattern (p=0.003) to be significantly associated with the need for reoperation. Adopting a strategy of fixation of all Vancouver B fractures involving the ES where the fracture was anatomically reducible and the bone cement interface was well-fixed was associated with a 5 year survival, free from reoperation of 88.8%


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results. A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 10 - 10
1 Aug 2021
Jain S Lamb J Townsend O Scott C Kendrick B Middleton R Jones S Board T West R Pandit H
Full Access

Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems. Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI). Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems. This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal-split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems had higher odds of bending type fractures (transverse and wedge) compared to PTS stems. Biomechanical testing is needed for validation and investigation of modifiable factors which may reduce the risk of unstable fracture patterns requiring complex revision surgery over internal fixation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 103 - 103
1 Jan 2016
Kim Y Tanaka C Maki A Tada H Kanoe H Shirai T
Full Access

Periprosthetic femoral fractures are becoming increasingly common and are a major complication of total hip arthroplasty (THA) and bipolar hemiarthroplasty (BHA). We report a retrospective review of the outcomes of treatment of 11 periprosthetic fractures after femoral revision using a long stem. Eleven female patients with a mean age of 79.2 years (70 to 91 years) were treated for a Vancouver type B1 fracture between 1998 and 2013. The status of the initial arthroplasty was THA in 5 patients and BHA in 6 patients. The original diagnosis was femoral neck fracture in 5 patients, osteoarthritis in 5 patients, and avascular necrosis of femoral head in 1 patient. Seven patients had had a cemented femoral component and 4 had had a cementless femoral component. The mean numbers of previous surgeries were 3.2 times (2 to 5 times). A previous history of fracture in the same femur was found in 7 hips including 5 femoral neck fractures, 3 periprosthetic fractures. The cause of the latest revision surgery was aseptic loosening in 6 hips, periprosthetic fracture in 3 hips, and infection in 2 hips. The average time to fracture after femoral revision using a long stem was 106.5 months (12 to 240 months). The average follow-up was 58.9 months (8 to 180 months). The fracture pattern was a transverse fracture in 6 hips and an oblique fracture in 5 hips. The type B1 fractures were treated with open reduction and internal fixation in 9 hips, 6 of which were reinforced with bone grafts. Seven patients were treated with a locking compression plate and cerclage wiring, and 2 patients were treated with a Dall-Miles system. Two other periprosthetic fractures were treated with femoral revision. One was revised because of stem breakage, and the other was a transverse fracture associated with very poor bone quality, which received a femoral revision with a long stem and a locking compression plate. All fractures except one achieved primary union. This failed case had a bone defect at the fracture site, and revision surgery using a cementless long stem and allografts was successful. These finding suggest that a type B1 fracture after revision using a long stem associated with very poor bone quality or bone loss might be considered as a type B3 fracture, and femoral revision might be the treatment of choice


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 144 - 144
1 Apr 2019
Prasad KSRK Kumar R Sharma A Karras K
Full Access

Background. Stress fractures at tracker after computer navigated total knee replacement are rare. Periprosthetic fracture after Minimally Invasive Plate Osteosynthesis (MIPO) of stress fracture through femoral tracker is unique in orthopaedic literature. We are reporting this unique presentation of periprosthetic fractures after MIPO for stress fracture involving femoral pin site track in computer assisted total knee arthroplasty, treated by reconstruction nail (PFNA). Methods. A 75-year old female, who had computer navigated right total knee replacement, was admitted 6 weeks later with increasing pain over distal thigh for 3 weeks without trauma. Prior to onset of pain, she achieved a range of movements of 0–105 degrees. Perioperative radiographs did not suggest obvious osteoporosis, pre-existent benign or malignant lesion, or fracture. Radiographs demonstrated transverse fracture of distal third of femur through pin site track. We fixed the fracture with 11-hole combihole locking plate by MIPO technique. Eight weeks later, she was readmitted with periprosthetic fracture through screw hole at the tip of MIPO Plate and treated by Reconstruction Nail (PFNA), removal of locking screws and refixation of intermediate segment with unicortical locking screws. Then she was protected with plaster cylinder for 4 weeks and hinged brace for 2 months. Results. Retrograde nail for navigation pin site stress fracture entails intraarticular approach with attendant risks including scatches to prosthesis and joint infection. So we opted to fix by MIPO technique. Periprosthetic fracture at the top of MIPO merits fixation with antegrade nail in conjunction with conversion of screws in the proximal part of the plate to unicortical locking screws. Overlap of at least 3cms offers biomechanical superiority. She made an uneventful recovery and was started on osteoporosis treatment, pending DEXA scan. Conclusion. Reconstruction Nail (PFNA), refixation of intermediate segment with unicortical locking screws constitutes a logical management option for the unique periprosthetic fracture after MIPO of stress fracture involving femoral pin site track in computer assisted total knee replacement


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims

Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures.

Methods

We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 295 - 295
1 Mar 2004
Daglar B Bayrakci K Gurkan I Ozdemir G Gunel U
Full Access

Aims: To investigate the clinical importance of the fracture of lumbar vertebral transverse processes and to þnd out if any correlations exists between the side and the level of the transverse processes fractures and speciþc intraabdominal organ injuries. Methods: 106 patients, sustained different kinds of trauma between January 2000 and January 2001, were included in the study. All patients were operated for intra abdominal causes. Of these 62 (%58) had one or more fractured lumbar transverse processes documented (group I) and remaining 44 had not (group II). Age, gender, additional skeletal and intra abdominal injuries, ISS, laboratory tests results at presentation, transfusion needs and the end results were compared using SPSS 10,0 package. Results: Patients with transverse process fractures were older (38 versus 27, p=0,001). Trauma causes, ISS, additional systemic traumas, skeletal traumas were not different between groups (p values are; 0,148, 0,125, 0,423, 0,673 respectively). However, hemoglobin levels, intra abdominal organ injuries, total hospital stay and end results were signiþcantly different in group I (p= 0,005, 0,042, 0,002 and 0,012). Left sided fractures were well correlated with the spleen, and right sided fractures were similarly correlated with the presence of hepatic injuries. Conclusions: Although lumbar transverse process fractures do not directly relate with vertebral stability, the presence of such a fracture should alert physicians. Especially in multiply injured patients, lumbar vertebra transverse process fracture predisposes more serious intra or retroperitoneal organ injuries


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 71 - 71
1 Mar 2006
Siegmeth A Brammar T Parker M
Full Access

Background: Reverse obliquity and transverse fractures of the proximal femur represent a distinct fracture pattern in which the mechanical forces displace the femur medially thus increasing the risk of fixation failure. There is a paucity of published literature in this area of trauma. This study constitutes the largest series of such fractures. Methods: Using the hip fracture registry at this institution 101 reverse obliquity and transverse fracture patterns were identified from 3336 consecutive hip fractures. All surviving patients were followed up for 1 year. Results: Of 100 patients treated operatively, 59 were treated with 1350 sliding hip screws (SHS), 22 were treated with 1350 sliding hip screw devices designed to resist medialization (3 sliding hip screws with trochanteric plate and 19 Medoff plates), and 19 were treated with intramedullary sliding hip screw devices (1 short Gamma nail, 9 long Gamma nails, 6 Reconstruction nails, 6 long Targon nails, 1 short Targon nail). The SHS had 4 failures (6.8%), and the intramedullary devices one failure (5.3%). Those extramedullary devices augmented to prevent medialization had higher failure rates (1 of 3 SHS with trochanteric plate and 3 of 19 Medoff plates), with combined failure rate of 15.8%. Conclusion: The 1350 SHS and the intramedullary devices had similar failure rates of 6.8% and 5.2% respectively. Those extramedullary devices designed to prevent medialization had higher failure rates (combined failure rate of 4/22 or 18%). This is similar to the high failure rate in 950 devices reported elsewhere. This suggests that extramedullary devices attempting to combat the difficult biomechanics of these fractures are unsuccessful. Better results can be obtained by using the standard 1350 SHS or with intramedullary sliding hip screw devices


Bone & Joint Research
Vol. 7, Issue 2 | Pages 139 - 147
1 Feb 2018
Takahara S Lee SY Iwakura T Oe K Fukui T Okumachi E Waki T Arakura M Sakai Y Nishida K Kuroda R Niikura T

Objectives. Diabetes mellitus (DM) is known to impair fracture healing. Increasing evidence suggests that some microRNA (miRNA) is involved in the pathophysiology of diabetes and its complications. We hypothesized that the functions of miRNA and changes to their patterns of expression may be implicated in the pathogenesis of impaired fracture healing in DM. Methods. Closed transverse fractures were created in the femurs of 116 rats, with half assigned to the DM group and half assigned to the control group. Rats with DM were induced by a single intraperitoneal injection of streptozotocin. At post-fracture days five, seven, 11, 14, 21, and 28, miRNA was extracted from the newly generated tissue at the fracture site. Microarray analysis was performed with miRNA samples from each group on post-fracture days five and 11. For further analysis, real-time polymerase chain reaction (PCR) analysis was performed at each timepoint. Results. Microarray analysis showed that there were 14 miRNAs at day five and 17 miRNAs at day 11, with a greater than twofold change in the DM group compared with the control group. Among these types of miRNA, five were selected based on a comparative and extended literature review. Real-time PCR analysis revealed that five types of miRNA (miR-140-3p, miR-140-5p, miR-181a-1-3p, miR-210-3p, and miR-222-3p) were differentially expressed with changing patterns of expression during fracture healing in diabetic rats compared with controls. Conclusions. Our findings provide information to further understand the pathology of impaired fracture healing in a diabetic rat model. These results may allow the potential development of molecular therapy using miRNA for the treatment of impaired fracture healing in patients with DM. Cite this article: S. Takahara, S. Y. Lee, T. Iwakura, K. Oe, T. Fukui, E. Okumachi, T. Waki, M. Arakura, Y. Sakai, K. Nishida, R. Kuroda, T. Niikura. Altered expression of microRNA during fracture healing in diabetic rats. Bone Joint Res 2018;7:139–147. DOI: 10.1302/2046-3758.72.BJR-2017-0082.R1


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 276 - 276
1 May 2010
Ashraf M Ellanti P Thakral R McEvoy F Sparkes J Mc Elwain J
Full Access

Introduction: Traditionally the fixation of choice as recommended by the AO ASIF group for transverse fractures of the Olecranon and the Patella is the tension band wiring technique. The concept of tension band wiring is based on the fact that the distractive force applied to one surface of the bone will result in compression on the opposite articular surface. Clinical outcomes of TBW are not equivocal. It is associated with significant morbidity such as non union, failure of fixation, especially in osteoporotic bone and infection which sometimes leads to amputation. Often a second procedure for removal of prominent metal work is required. In our biomechanical study we investigated this concept as we believe that the forces generated by TBW construct do not generate significant compressive forces required for healing of fracture. Materials and Methods: We used 4th generation composite bones (Sawbones. ®. , Malmoe, Sweden.). These bone analogues have been validated to closely simulate human bone characteristics for fracture toughness, tensile strength, compressive strength, fatigue crack resistance and implant subsidence. The advantage of using 4th generation composite bone model is that it provides uniformity which is not achievable in cadaveric studies. Two different bone models representative of Olecranon and patella were used. Transverse fractures were created in the bones and fixed with TBW technique as described in A.O. manual. Two 0.062-inch Kirschner wires and figure of eight configuration of 18G Stainless steel wire with single knot technique was used. Micro motion transducers (DVRT: MicroStrain, Williston, Vermont) with an accuracy of ± 1μm were placed across the fracture site both anteriorly and posteriorly. Continuous information regarding fracture distraction and compression, as determined by the transducers was recorded from both sites simultaneously during the experiment. The tension band wire construct was loaded up to a maximum force of 4000 Newtons for patella and 500 for the olecranon. The fractures were subjected to cyclic loading at 1Hz using a servo hydraulic materials-testing system (model 8500; Instron, Canton, Massachusetts). The results were analysed on a computer and statistical analysis performed. Results: During the application of cyclical loading, we noted a gap at the articular surface ranging from 1.1± 0.4mm and 2.1± 0.6mm for Olecranon and patella constructs respectively. During most of the duration of the experiment no transducer displacements were recorded at the articular surface. Conclusion: The concept that distractive forces at one end could be converted to compression at the other end through the TBW does not hold true in our biomechanical study. A simpler construct may suffice for fixation of patellar and Olecranon fractures which can reduce the complications associated with TBW fixation


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 146 - 146
1 Mar 2009
Piltz S Pieske O Karin H
Full Access

Introduction: Bilateral and transverse fractures of the first two sacral vertebrae with intrapelvic intrusion of the lumbo-sacral spine are very rare injuries. In most cases the lesion occurs after a fall from great height in a kyphotic position when landing. Today’s CT-scans in these mostly polytraumatized patients enable a clear diagnosis. In contrast conventional radiographs have a high risk to ignore these fractures. Operative treatment requires proper reduction and secure fixation which so far is not unrestricted possible using recommended techniques. For reduction lumbo-sacral distraction followed by lordotic extension is essential but difficult to obtain. Therefore we modified the lumbo-pelvic instrumentation to facilitate these requirements. Methods: In the last four years we treated three female patients (aged 27–68 years) as follows: Variable axis screws (VAS – Synthes®) were inserted in the L4 and L5 pedicles and connected with two connecting rods. An additional variable axis screw was inserted in each posterior iliac spine. These both screws were connected with a transverse connecting rod situated over the transverse fracture line. This rod was connected with the two upright rods using a rod-to-rod connector and forming a hinged joint. Due to the not tightened nut of the pedicle screws at that time it was possible to spread the lumbo-sacral fracture line. After tightening of the lumbar screws the upper part of the body was slightly elevated resulting in a lordotic extension in the hinged joint. Subsequently the hinged joint was locked (Video). Results: Postoperative CT scans revealed anatomic reduction and properly inserted implants in all cases. Follow-up was uneventful but a heparin related thrombopenia in one patient. Two patients were mobilized under full weight bearing within 4 and 10 days, respectively. In one cases this was not possible because of relevant foot fractures. Neurological deficits completely resolved in one patient within fourteen days and markedly diminished in another patient within months (persistent neuralgia). In one patient no neurological deficit existed. In all cases a complete hardware removal was done in 8 to 11 months. Conclusions: The presented procedure is suitable for the so-called jumper’s fractures and results in anatomic reduction of the displaced fractures and a secure stabilization. The described hinged joint offers effective lordotic extension which is the key point for reduction. Thus this configuration is a reduction as well a fixation device. Full weight bearing in an erect posture is immediately possible and clearly shorten the rehabilitation period


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 66 - 66
1 Apr 2018
Chang C Yang C Chen Y Chang C
Full Access

For the management of displaced patellar fractures, surgical fixation using cannulated screws along with anterior tension band wiring is getting popular. Clinical and biomechanical studies have reported that using cannulated screws and a wire instead of the modified tension band with Kirschner wires improves the stability of fractured patellae. However, the biomechanical effect of screw proximity on the fixed construction remains unclear. The aim of this study was to evaluate the mechanical behaviors of the fractured patella fixed with two cannulated screws and tension band at different depths of the patella using finite element method. A patella model with simple transverse fracture [AO 34-C1] was developed; the surgical fixation consisted of two 4.0-mm parallel partial-threaded cannulated screws with a figure-of-eight anterior tension band wiring using a 1.25-mm stainless steel cable. Two different locations, including the screws 5-mm and 10-mm away from the leading edge of the patella, were used. A tension force of 850 N was applied on the patellar apexes at two loading angles (45° and 0° [parallel] to the long axis) to simulate different loading conditions while knee ambulation. The proximal side (base) of the patella was fixed, and the inferior articular surface was defined as a compression-only support in ANSYS to simulate the support from distal femur condyles. Compression-only support enables the articular surfaces of the present patella to only bear compression and no tension forces. Under different loading conditions, the fixed fractured patella yielded higher stability during 0° loading of tension force than during 45° loading. When the screws were parallel placed at the depth of 5 mm away from the patellar surface, the deformation of patellar fragment and maximum gap opening at the fracture site were smaller than those obtained by screws placed at the depth of 10 mm away from the patellar surface. Compared to the superficial screw placement, the deeper placement (10 mm) increased the maximum gap opening at the fracture site by 1.56 times under 45° loading, and 1.58 times under 0° loading. The load on the tension band wire of the 10-mm screw placement was 3.12 times (from 230 to 717 N) higher than that of the 5-mm placement. Under the wire, the contact pressure on the patellar surface was higher with the 10-mm screw placement than the 5-mm screw placement. The peak bone contact pressures with the 10-mm placement were 7.7 times (99.5 to 764 MPa) higher. This is the first numerical study to examine the biomechanical effects of different screw locations on the fixation of a fractured patella using screws and tension band. Based on a higher stability and lower cable tension obtained by the superficial screws placement, the authors recommended the superficial screw placement (5 mm below the leading edge of the patella) rather than the deep screws while fixing the transverse patellar fracture with cannulated screws and cable


Bone & Joint Open
Vol. 4, Issue 8 | Pages 612 - 620
21 Aug 2023
Martin J Johnson NA Shepherd J Dias J

Aims

There is ambiguity surrounding the degree of scaphoid union required to safely allow mobilization following scaphoid waist fracture. Premature mobilization could lead to refracture, but late mobilization may cause stiffness and delay return to normal function. This study aims to explore the risk of refracture at different stages of scaphoid waist fracture union in three common fracture patterns, using a novel finite element method.

Methods

The most common anatomical variant of the scaphoid was modelled from a CT scan of a healthy hand and wrist using 3D Slicer freeware. This model was uploaded into COMSOL Multiphysics software to enable the application of physiological enhancements. Three common waist fracture patterns were produced following the Russe classification. Each fracture had differing stages of healing, ranging from 10% to 90% partial union, with increments of 10% union assessed. A physiological force of 100 N acting on the distal pole was applied, with the risk of refracture assessed using the Von Mises stress.


Bone & Joint Open
Vol. 4, Issue 1 | Pages 38 - 46
17 Jan 2023
Takami H Takegami Y Tokutake K Kurokawa H Iwata M Terasawa S Oguchi T Imagama S

Aims

The objectives of this study were to investigate the patient characteristics and mortality of Vancouver type B periprosthetic femoral fractures (PFF) subgroups divided into two groups according to femoral component stability and to compare postoperative clinical outcomes according to treatment in Vancouver type B2 and B3 fractures.

Methods

A total of 126 Vancouver type B fractures were analyzed from 2010 to 2019 in 11 associated centres' database (named TRON). We divided the patients into two Vancouver type B subtypes according to implant stability. Patient demographics and functional scores were assessed in the Vancouver type B subtypes. We estimated the mortality according to various patient characteristics and clinical outcomes between the open reduction internal fixation (ORIF) and revision arthroplasty (revision) groups in patients with unstable subtype.