To assess the current literature on
Introduction. This study was performed prospectively and randomly to compare clinical outcomes of modified-Brostrom procedure using single and double
Introduction and Aims: To evaluate the technique of the knotless
Restoring of anatomic footprint may improve the healing and mechanical strength of repaired tendons. A double row of
Purpose: The use of a bioabsorbable
Background: Arthroscopic stabilisation surgery for the shoulder remains a controversial choice of treatment for post traumatic anterior instability. We present the results of a consecutive initial series of 50 patients who were stabilised using a knotless labral repair technique. Methods: The study group included 41 men and 9 women with an average age of 26 years. 58% were affected on the dominant side. The average duration of preoperative syptoms was 3.8 years. 72% of patients had dislocations, whilst the remainder experienced subluxations. Each patient underwent a standardised procedure by the same surgeon with a regional interscalene block and/or general anaesthesia. Anchors were placed in the 3, 4 and 5 o’clock positions. Each patient was assessed using the Constant, Rowe and Walch-Duplay scores at an average of 18 months follow up (range 12–36 months). Results: At review 95% of shoulders remained stable. One patient had a true dislocation 6 months post surgery. One patient experienced a subluxation following a direct whilst skiing. 6 patients remained apprehensive. 3 patients had minor restriction of external rotation. The average Rowe score was 90.8, average Constant score was 89.9 and the average Walch-Duplay score was 81.4Conclusions: Early results indicate that capsulolabral reconstruction using the knotless
The behaviour of two different methods of reattachment of the flexor digitorum profundus tendon insertion was assessed. Cyclical testing simulating the first 5 days of a passive mobilisation protocol was used to compare the micro Mitek anchor to the modified-Bunnell pull-out suture. Twelve fresh-frozen cadaveric fingers were dissected to the insertion of the FDP tendon. The FDP insertion was then sharply dissected from the distal phalanx and repaired using one of two methods: group 1 -modified Bunnell pullout suture using 3/0 Prolene; group 2 micro Mitek anchor loaded with 3/0 Ethibond inserted into the distal phalanx. Each repaired finger was mounted on to a material testing machine using pneumatic clamps. We cyclically tested the repair between 2N and 15N using a load control of 5N/s for a total of 500 cycles. Gap formation at the tendon bone interface was measured every 100 cycles. No specimens failed during cyclical testing. After 500 cycles, gap formation of the tendon-bone interface was 6.6mm (SD = 1.2mm), and 2.1 mm (SD = 0.3mm) for the pullout technique and the micro Mitek anchor repair respectively. Concerns related to
Arthroscopic stabilisation of the shoulder is a technically-demanding and developing technique, and the reported results have yet to match those for open surgery. We present a consecutive initial series of 55 patients with post-traumatic recurrent anteroinferior instability managed since September 1999 using a titanium knotless
One of the recently introduced anchors is the absorbable
Research in to tendon-bone healing techniques focus on increasing bone growth at the interface such as cell or growth factor (e.g. BMP-2) augmentation. Demineralised bone matrix (DBM) is osseoinductive and is in use clinically. Hypothesis: DBM augmentation of a healing tendon-bone interface will result in improved function at 3, 6, 9 and 12 weeks, and a morphology that more closely resembles that of a normal enthesis at 12 weeks. Materials and methods: An ovine patellar tendon model was used. 19 skeletally mature ewes were allocated to the control group or DBM group. In both groups the patellar tendon was detached, and following tibial tubercle osteotomy, was re-attached using 3
Aims. This study aimed to establish the optimal fixation methods for calcaneal tuberosity avulsion fractures with different fragment thicknesses in a porcine model. Methods. A total of 36 porcine calcanea were sawed to create simple avulsion fractures with three different fragment thicknesses (5, 10, and 15 mm). They were randomly fixed with either two
Introduction.
The incidence of rotator cuff tears increases with age, thus the rotator cuff tear is often associated with osteoporotic or osteopenic bone in the proximal humerus, especially with female patients. For testing of fixation devices such as
This study aims to compare the biomechanical properties of the “Double Lasso-Loop”
Rotator cuff tears are a common cause of shoulder pain and dysfunction. Therefore, the purpose of this in-vitro biomechanical study was conducted to determine the effects of simulated tears and subsequent repairs of the rotator cuff tendons on joint kinematics. Eight paired fresh-frozen cadaveric shoulder specimens (mean age: 66.0 ± 8.7 years) were tested using a custom loading apparatus designed to simulate unconstrained motion of the humerus. Cables were sutured to the rotator cuff tendons and the deltoid. Loads were applied to the cables based on variable ratios of electromyographic (EMG) data and average physiological cross-sectional area (pCSA) of the muscles. An electromagnetic tracking device (Flock of Birds, Ascension Technologies, VT) was used to provide real-time feedback of abduction angle, to which the loading ratio was varied correspondingly. 2 and 4cm tears were made starting at the rotator cuff interval and extending posteriorly. Specimens were randomised to receive either single or double
Glenohumeral chondrolysis is a devastating condition characterized by the rapid dissolution of glenohumeral cartilage and resultant joint destruction. Excessive intra-articular use of thermal heat,
Introduction: Arthroscopic stabilisation of shoulder joint for instability following a traumatic dislocation is gaining popularity. It has various advantages like being minimally invasive, causes minimal damage to the shoulder muscles, quicker rehabilitation, minimal loss of external rotation, and addresses the pathology. This can be performed using non-absorbable