Advertisement for orthosearch.org.uk
Results 1 - 20 of 1051
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 78 - 78
1 Dec 2017
Takoudju E Guillouzouic A Stanimir K Pecorari F Corvec S
Full Access

Aim. Although there are no treatment guidelines for Propionibacterium acnes (PA) bone and joint infections (Corvec et al Acta Orthopedica 2016), these infections can be treated with a combination of fluoroquinolones and rifampicin. Rifampicin resistance have already been reported either in in vitro selected mutants or clinical isolates (Furustrand et al JAC 2013, Anaerobe 2015). Minimal inhibitory concentrations of levofloxacin (LVX) ranging from 0,12 to 0.5mg/L are regularly observed but resistance has not yet been investigated. We investigated the in vitro emergence of LVX resistance and characterized the mutations involved in gyrA gene. Method. The strain of PA ATCC11827 (MIC LVF = 0.25 mg/L) was used. The frequency of mutation was determined after inoculation of 108 PA on blood agar containing concentrations of 2 to 128 times the MIC incubated for 7 days in anaerobiosis at 35 ° C. The emergence of high-level of resistance was also studied from the low-level mutants after a second exposure. For the resistant mutants, the gyrA and parC genes were sequenced and compared to the PA reference sequences. Results. The mutation frequency was 3.8 cfu × 10–8 (8×MIC) and 1.6 cfu × 10–7 (4×MIC), respectively. A low or high-level resistance to LVX was observed. MICs varied between 0.75 and> 32 mg/L and were stable after three subcultures. 87 mutants were studied including 40 with a mutation in gyrA gene. 10 different genotypes could be demonstrated with either high-level resistance: G99 (n = 4), G99 D (n = 3), D100N (n = 1), S101 L (n = 14), S101W N = 5) or low-level resistance D100H (n=1), D100G (n=1), A102P (n=5), D105 H (n = 4), D105 G (n = 2). Substitution 101 always leads to a high level of resistance. No mutation was found in parC gene. Conclusions. To our knowledge, this is the first description of the emergence of LVX resistance in PA. The MIC increases from sensitivity to low or high-level resistance. This resistance is stable and associated exclusively with mutations in the gyrA gene. Six different positions give rise to ten different genotypes. The passage from a low to a high-level resistance is done mainly by the selection of the mutation at position 101. Finally, some mutants do not exhibit mutations in QRDRs, suggesting the existence of an efflux system


Bone & Joint Research
Vol. 11, Issue 2 | Pages 121 - 133
22 Feb 2022
Hsu W Lin S Hung J Chen M Lin C Hsu W Hsu WR

Aims. The decrease in the number of satellite cells (SCs), contributing to myofibre formation and reconstitution, and their proliferative capacity, leads to muscle loss, a condition known as sarcopenia. Resistance training can prevent muscle loss; however, the underlying mechanisms of resistance training effects on SCs are not well understood. We therefore conducted a comprehensive transcriptome analysis of SCs in a mouse model. Methods. We compared the differentially expressed genes of SCs in young mice (eight weeks old), middle-aged (48-week-old) mice with resistance training intervention (MID+ T), and mice without exercise (MID) using next-generation sequencing and bioinformatics. Results. After the bioinformatic analysis, the PI3K-Akt signalling pathway and the regulation of actin cytoskeleton in particular were highlighted among the top ten pathways with the most differentially expressed genes involved in the young/MID and MID+ T/MID groups. The expression of Gng5, Atf2, and Rtor in the PI3K-Akt signalling pathway was higher in the young and MID+ T groups compared with the MID group. Similarly, Limk1, Arhgef12, and Araf in the regulation of the actin cytoskeleton pathway had a similar bias. Moreover, the protein expression profiles of Atf2, Rptor, and Ccnd3 in each group were paralleled with the results of NGS. Conclusion. Our results revealed that age-induced muscle loss might result from age-influenced genes that contribute to muscle development in SCs. After resistance training, age-impaired genes were reactivated, and age-induced genes were depressed. The change fold in these genes in the young/MID mice resembled those in the MID + T/MID group, suggesting that resistance training can rejuvenate the self-renewing ability of SCs by recovering age-influenced genes to prevent sarcopenia. Cite this article: Bone Joint Res 2022;11(2):121–133


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 56 - 56
1 Oct 2022
Stevoska S Himmelbauer F Stiftinger J Stadler C Pisecky L Gotterbarm T Klasan A
Full Access

Aim. Antimicrobial resistance (AMR) aggravates an already difficult treatment of periprosthetic joint infections (PJI). The prevalence of drug-resistant pathogens varies across countries and increases over time. Regular monitoring of bacteriological analyses should be performed. Due to many factors influencing the AMR, the correct choice of antimicrobial management remains arguable. The primary purpose of this retrospective study was to identify and compare causative bacteria and to compare the incidence of antibiotic resistance between the septic revision total knee arthroplasty (TKA) and septic revision total hip arthroplasty (THA). Method. A review of all revision TKAs and revision THAs, undertaken between 2007 and 2020 in a tertiary referral centre, was performed. Included were cases meeting the consensus criteria for PJI, in which an organism has been identified. There were no major differences in tissue sampling between revision TKAs and revision THAs over time. Results. A total of 228 bacterial strains, isolated after revision TKA and THA, were analysed for their resistance to 20 different antibiotics. There was a statistically significant higher occurrence of Gram-negative bacteria (p=0.002) and Enterococcus species (p=0.026) identified after revision THAs compared to TKA. The comparison of antibiotic resistance between revision TKAs and revision THAs was statistically significant in 9 of 20 analysed antibiotics. Pathogens isolated after revision THA were much more resistant compared to pathogens isolated after revision TKA. Resistance in revision THAs was significantly higher to oxacillin (p=0.03), ciprofloxacin (p<0.001), levofloxacin (p<0.001), moxifloxacin (p=0.005), clindamycin (p<0.001), co-trimoxazole (p<0.001), imipenem (p=0.01), rifampicin (p=0.005) and tetracycline (p=0.009). There was no significantly higher resistance of pathogens isolated after revision TKAs detected. No statistically significant difference in antibiotic resistance of Gram-negative bacteria between revision TKA and revision THA was observed. Conclusions. The occurrence and the resistance of bacteria to antibiotics differs significantly between revision TKAs and revision THAs. This has implications on of the choice of empirical antibiotic in revision surgery as well as prophylactic antibiotic in primary surgery, depending on the joint that is to be replaced


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 575 - 580
2 May 2022
Hamad C Chowdhry M Sindeldecker D Bernthal NM Stoodley P McPherson EJ

Periprosthetic joint infection (PJI) is a difficult complication requiring a comprehensive eradication protocol. Cure rates have essentially stalled in the last two decades, using methods of antimicrobial cement joint spacers and parenteral antimicrobial agents. Functional spacers with higher-dose antimicrobial-loaded cement and antimicrobial-loaded calcium sulphate beads have emphasized local antimicrobial delivery on the premise that high-dose local antimicrobial delivery will enhance eradication. However, with increasing antimicrobial pressures, microbiota have responded with adaptive mechanisms beyond traditional antimicrobial resistance genes. In this review we describe adaptive resistance mechanisms that are relevant to the treatment of PJI. Some mechanisms are well known, but others are new. The objective of this review is to inform clinicians of the known adaptive resistance mechanisms of microbes relevant to PJI. We also discuss the implications of these adaptive mechanisms in the future treatment of PJI. Cite this article: Bone Joint J 2022;104-B(5):575–580


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 44 - 44
1 Oct 2022
Young B Dudareva M Vicentine M Hotchen A McNally M
Full Access

Aim. Local antibiotic treatment for bone and joint infections offers direct delivery of high concentrations of antibiotics with reduced systemic exposure and favourable safety profile. However, the possibility of prolonged release of antibiotics at sub-therapeutic levels creates concern about the possible development of antimicrobial resistance. We investigated patients with recurrent bone and joint infection for evidence of antimicrobial resistance emerging from the use of local antibiotics. Method. 125 patients with recurrent infection (prosthetic joint infection, fracture related infection and osteomyelitis) in the UK between 2007 and 2021 were identified. Electronic patient records (including operative notes, pathology results and prescriptions) were reviewed to extract site of infection, date of surgery, the use of local antibiotics, culture results, empiric and definitive antibiotic therapy. All antibiotic sensitivity results were recorded as sensitive, intermediate or resistant according to contemporary guidelines (BSAC and EUCAST). Results. Local antibiotics were used in 74/125 (59.2%) of patients. Agents used were Gentamicin 53/125 (42.4%), Tobramycin 18/125 (14.4%), and vancomycin in 19/125 (15.2%). Combined gentamicin and vancomycin usage was seen in 16/125 patients (12.8%). Gentamicin non-sensitivity was common in this cohort with frequent aminoglycoside use. At index procedure, a Gentamicin non-sensitive organism was cultured in 51/125 patients (40.8%). At re-operation this proportion was lower: 40/125 (32%). There was no statistically significant difference in the rate of Gentamicin resistance at reoperation comparing patients who previously received local aminoglycosides with those who had not (21/71, 29.8% vs 19/54, 35.2% p=0.6, chi-squared test). In 48/125 (38.4%) of patients, the same species was isolated during the index and recurrence surgery. We identified 7 cases with new aminoglycoside resistance arising at the second procedure. In 2/7 – S. aureus and E. faecalis - aminoglycoside resistance was the only change in antimicrobial sensitivity. In 5/7, there were at least 2 additional changes in observed antimicrobial sensitivity. 3/74 (4%) of cases who initially received local aminoglycoside cultured organisms with aminoglycoside resistance at recurrence. 4/51 (7.8%) of those who did not receive local or systemic aminoglycoside at index surgery cultured resistant organisms (chi square 0.82; p=0.365). Conclusions. As a group, patients whose treatment for orthopaedic infection included local antibiotics did not exhibit higher rates of specific antimicrobial resistance compared with those not treated with local antibiotics. However we did identify cases where Gram positive bacteria developed aminoglycoside resistance regardless of their initial antimicrobial therapy. This should be considered in antimicrobial choice during surgery for recurrence


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 394 - 394
1 Oct 2006
Page J Natrass F Fawcett T Cook P Jennings A
Full Access

A phenomenon of methicillin resistance in methicillin sensitive Staphylococcus aureus has been noted in organisms living in biofilm induced by the state of cell wall deficiency. The rate and the amount of biofilm formed by the cell wall deficient organisms far exceeds that of cell wall patent organisms. Once removed from the biofilm the S. aureus had the same sensitivities of the original organism. Cell wall deficient organisms outside the biofilm did not demonstrate the methicillin resistance. A known laboratory strain (ATCC 9144) was induced into a cell wall deficient state and allowed to form biofilm. The rate of formation and amount formed was compared with that formed by cell wall patent organisms. Before inducing cell wall deficiency sensitivity to methicillin was demonstrated using standard microbiological technique. Using an oxacillin containing plate as a culture medium: the biofilm, cell wall deficient organisms and the cell wall competent organisms were inoculated onto separate media. Organisms from the biofilm were isolated and grown free of the biofilm on blood agar. Any growth on the oxacillin containing plate would demonstrate methicillin resistance. There was no growth on the plates containing the cell wall competent or cell wall deficient organisms. There was however growth on the plate inoculated with bio-film, however when organisms were isolated from the biofilm, there was no growth on the media. Antibiotic sensitivities of the original inoculant and the organisms isolated from the biofilm were the same. The biofilm, induced as a result of cell wall deficiency, offers a form of structural protection to the Staphylococcus aureus without altering the resistance pattern of organism. Standard microbiological techniques would therefore report the organism as methicillin sensitive, however clinically the organism may behave as a methicillin resistant organism. The state of cell wall deficiency encourages the formation of biofilm in S. aureus. In-vitro the state of cell wall deficiency is induced using high osmolality media or sub-lethal doses of cell wall active antibiotics. Both these states are found in clinical practice


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 54 - 54
1 Oct 2022
Mitterer JA Frank BJ Gardete-Hartmann S Panzenboek LF Simon S Krepler P Hofstaetter JG
Full Access

Aim. In severe cases of postoperative spinal implant infections (PSII) multiple revision surgeries may be needed. Little is known if changes of the microbiological spectrum and antibiotic resistance pattern occur between revision surgeries. Therefore, the aim of this study was to analyze the microbiological spectrum and antibiotic resistance pattern in patients with multiple revision surgeries for the treatment of PSII. Furthermore, changes of the microbiological spectrum, distribution of mono vs. polymicrobial infections, and changes of the antimicrobial resistance profile in persistent microorganisms were evaluated. Method. A retrospective analysis of a prospectively maintained single center spine infection database was performed with a minimum follow-up of 3 years. Between 01/2011 and 12/2018, 103 patients underwent 248 revision surgeries for the treatment of PSII. Overall, 20 patients (6 male/14 female) underwent 82 revisions for PSII (median 3; range 2–12). There were 55/82 (67.1%) procedures with a positive microbiological result. Microbiological analysis was performed on tissue and implant sonication fluid. Changes in microbial spectrum and antibiotic resistance pattern between surgeries were evaluated using Chi-Square and Fisher's exact test. Results. In total, 74 microorganisms (83.3% gram-positive; 10.8% gram-negative) were identified. The most common microorganisms were Staphylococcus epidermidis (18.9%) and Cutibacterium acnes (18.9%). All S. epidermidis identified were methicillin-resistant (MRSE). Overall, there were 15/55 (27.3%) polymicrobial infections. The microbiological spectrum changed in 57.1% (20/35) between the revision stages over the entire PSII period. In 42.9% (15/35) the microorganism persisted between the revision surgeries stages. Overall, changes of the antibiotic resistance pattern were seen in 17.4% (8/46) of the detected microorganisms comparing index revision and all subsequent re-revisions. Moreover, higher resistance rates were found for moxifloxacin and for ciprofloxacin at first re-revision surgery compared with index PSII revision. Resistances against vancomycin increased from 4.5% (1/23) at index PSII revision to 7.7% (2/26) at first re-revision surgery. Conclusions. Changes of the microbiological spectrum and the resistance pattern can occur in patients with severe PSII who require multiple revision surgeries. It is important to consider these findings in the antimicrobial treatment of PSII. The microbiological analysis of intraoperative tissue samples should be performed at every revision procedure for PSI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 63 - 63
24 Nov 2023
Prebianchi SB Santos INM Brasil I Charf P Cunha CC Seriacopi LS Durigon TS Rebouças MA Pereira DLC Dell Aquila AM Salles M
Full Access

Aim. Community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA) is commonly associated with serious cases of community-onset skin and musculoskeletal infections (Co-SMSI). Molecular epidemiology analysis of CA-MRSA recovered from skin and soft tissues specimens is lacking in Latin America. This study aimed to identify phenotypic and genotypic features of MRSA isolates recovered from patients presenting Co-SMSI. Methods. Consecutive MRSA isolates recovered from Co-SMSI of patients admitted from March 2022 to January 2023 in a Brazilian teaching hospital were tested for antimicrobial resistance and characterized by their genotypic features. Identification was carried out by automated method and through MALDI-TOF MS. Antimicrobial susceptibility was tested by disk diffusion, broth microdilution and E-test strips for determination of the minimal inhibitory concentration (MIC) according to recommendations from the Brazilian Committee on Antimicrobial Susceptibility Testing (BrCAST) and European Committee on Antimicrobial Susceptibility Testing (EUCAST). Gene mecA characterization and Sccmec typing were performed by multiplex polymerase chain reaction (PCR) assay, and gene lukF detection by single PCR. Patients were prospectively followed up for two months, in order to determine their clinical characteristics and outcomes. Results. Overall, 48 Staphylococcus aureus isolates were obtained from 68 samples recovered from patients with Co-SMSI. Twenty two (42%) were phenotypically characterized as MRSA, although mecA gene was only identified in 20 of those samples. Sccmec was untypable in 12 isolates, Sccmec was type II in 4 isolates and 2 were classified as type IVa. LukF gene was identified in 5 isolates. Antimicrobial resistance profile showed that all isolates were susceptible to linezolid and vancomycin with MIC = 1 and MIC = 2 in 66,7% and 33.3%, respectively. Susceptibility to quinolones was worryingly low and none of the isolates were sensitive to usual doses of ciprofloxacin and levofloxacin, and showed increased rates of resistance to increased exposure to these drugs, as well. Isolates were both susceptible to gentamicin and tetracycline in 85% and resistance to also Sulfamethoxazole/Trimethoprim occurred in only 2 isolates. Mortality rate evaluated within 1 month of the initial evaluation was 10% among MRSA isolates. Conclusions. Our results showed that CA-MRSA isolates causing Co-SMSI demonstrated an alarming pattern of multidrug resistance, including to β-lactam and quinolones, which have been commonly prescribed as empirical therapy for patients with skin, soft tissue and musculoskeletal infections


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 8 - 8
1 Oct 2020
Klasan A Bowman M Schermuksnies A Gerber F Malcherczyk D Fuchs-Winkelmann S Heyse TJ
Full Access

Introduction. Management of periprosthetic joint infection (PJI) after total knee arthroplasty (TKA) is a challenging task. Antibiotic management remains elusive due to differences in epidemiology and resistance between countries and reports. Increasing resistance of bacteria is a concern. The aim of this study was to investigate the development of antibiotic resistance of main causative bacteria in a single center. Methods. A retrospective review of all revision TKA between 2006 and 2018 in a tertiary referral center was performed. Included were cases meeting the consensus criteria for PJI with at least two positive cultures. Three chronological groups were created using a two-step cluster analysis. Results. In 129 cases of PJI there were 161 different bacteria identified by growth in culture. Of all bacteria 76.4% were gram positive, 23.6% were gram negative. Coagulase-negative Staphylococci (CNS) were diagnosed in 46.6% cultures, followed by Staphylococcus aureus in 19.8% of cultures. Overall antibiotic resistance (p=0.454) and Staphylococcus aureus resistance (p=0.788) have not increased during the study period. CNS resistance to teicoplanin (4% to 44%; p<0.001), fosfomycin (16% to 44%, p=0.016) and tetracycline (0% to 28%, p=0.014) increased significantly. Vancomycin had an 84.4% overall sensitivity and 100% CNS sensitivity and remained the most effective agent. Conclusion. The increasing resistance to several antibiotics over a little more than a decade is concerning. This study suggests that referral centres should continuously monitor obtained cultures as this has significant implications for both prophylactic treatment in primary as well as empirical antibiotic treatment in PJI. Resistance profiles may differ between centres and are subject to dynamic changes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 66 - 66
11 Apr 2023
Sebastian S Collin M Liu Y Raina D Tägil M Lidgren L
Full Access

There is a lack of carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotic for Staphylococcus aureus deep bone infections (DBIs). RIF is also associated with systemic side effects, and known for causing rapid development of antibiotic resistance when given as monotherapy. We evaluated a clinically usedbi-phasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). It was hypothesized that this combined approach could provide improved biofilm eradication and prevent the development of RIF resistance. Methods: 1) Biofilm eradication: Using a modified crystal violet staining biofilm quantification method, the antibiotics released at different time points (Day 1, 3, 7, 14, 21, 28 and 35) from the hemispherical pellets of CaS/HA(500 mg)-VAN (24.57 mg) / GEN (10.35 mg) composites with or without RIF (8.11 mg) were tested for their ability to disrupt the preformed 48-h old biofilms of S. aureus ATCC 25923, and S. aureus clinical strain P-3 in 96-well microtitre plate. For each tested group of antibiotic fractions, five separate wells were used (n=5). 2) Testing for resistance development: Similar to the method mentioned above the 48-h biofilm embeded bacteria exposed to antibiotic fractions from different time points continuously for 7 days. The biofilms remained were then tested for RIF resistant strains of bacteria. Overall, there was clear antibiofilm biofilm activity observed with CaS/HA-VAN/GEN+RIF combinations compared with CaS/HA-VAN/GEN alone. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with combinations of CaS/HA-VAN/GEN+RIF. Enhanced antibiofilm effects without development of RIF resistance indicates that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for additional local delivery in clinically demanding DBIs. Acknowledgement: We deeply acknowledge the Royal Fysiographic Society of Lund, Landshövding Per Westlings Minnesfond and the Stina and Gunnar Wiberg fond for financial support


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 45 - 45
14 Nov 2024
Kjeldsen T Thorgaard Skou S Dalgas U Tønning L Birch S Frydendal T Varnum C Garval M G Ingwersen K Mechlenburg I
Full Access

Introduction. Exercise is recommended as first-line treatment for patients with hip osteoarthritis (OA). Interestingly, content and dose of exercise interventions seem to be important for the effect of exercise interventions, but the optimal content and dose is unknown. This warrants randomized controlled trials providing evidence for the optimal exercise program in Hip OA. The aim of this trial was to investigate whether progressive resistance training (PRT) is superior to neuromuscular exercise (NEMEX) for improving functional performance, hip pain and hip-related quality of life in patients with hip OA. Method. This was a multicenter, cluster-randomized, controlled, parallel-group, assessor-blinded, superiority trial. 160 participants with clinically diagnosed hip OA were recruited from hospitals and physiotherapy clinics and randomly assigned to twelve weeks of PRT or NEMEX. The PRT intervention consisted of 5 high-intensity resistance training exercises targeting muscles at the hip and knee joints. The NEMEX intervention included 10 exercises and emphasized sensorimotor control and functional stability. The primary outcome was change in the 30-second chair stand test (30s-CST). Key secondary outcomes were changes in scores on the pain and hip-related quality of life (QoL) subscales of the Hip Disability and Osteoarthritis Outcome Score (HOOS). Result. The mean changes from baseline to 12-week follow-up in the 30s-CST were 1.5 (95% CI, 0.9 to 2.1) chair stands with PRT and 1.5 (CI, 0.9 to 2.1) chair stands with NEMEX (difference, 0.0 [CI, 0.8 to 0.8] chair stands). For the HOOS pain subscale, mean changes were 8.6 (CI, 5.3 to 11.8) points with PRT and 9.3 (CI, 5.9 to 12.6) points with NEMEX. For the HOOS QoL subscale, mean changes were 8.0 (CI, 4.3 to 11.7) points with PRT and 5.7 (CI, 1.9 to 9.5) points with NEMEX. Conclusion. In patients with hip OA, PRT is not superior to NEMEX for improving functional performance, hip pain, or hip-related QoL


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 12 - 12
1 Feb 2021
Pianigiani S Verga R
Full Access

A common location for radius fracture is the proximal radial head. With the arm in neutral position, the fracture usually happens in the anterolateral quadrant (Lacheta et al., 2019). If traditional surgeries are not enough to induce bone stabilization and vascularization, or the fracture can be defined grade III or grade IV (Mason classification), a radial head prosthesis can be the optimal compromise between bone saving and recovering the “terrible triad”. A commercially available design of radial head prosthesis such as Antea (Adler Ortho, Milan, Italy) is characterized by flexibility in selecting the best matching size for patients and induced osteointegration thanks to the Ti-Por. ®. radial stem realized by 3D printing with laser technique (Figure 1). As demonstrated, Ti-Por. ®. push-out resistance increased 45% between 8 −12 weeks after implantation, hence confirming the ideal bone-osteointegration. Additional features of Antea are: bipolarity, modularity, TiN coating, radiolucency, hypoallergenic, 10° self-aligning. The osteointegration is of paramount importance for radius, in fact the literature is unfortunately reporting several clinical cases for which the fracture of the prosthesis happened after bone-resorption. Even if related to an uncommon activity, the combination of mechanical resistance provided by the prosthesis and the stabilization due to the osteointegration should cover also accidental movements. Based upon Lacheta et al. (2019), after axial compression-load until radii failure, all native specimens survived a compression-load of 500N, while the failure happened for a mean compression force of 2560N. The aim of this research study was to test the mechanical resistance of a radial head prosthesis obtained by 3D printing. In detail, a finite element analysis (FEA) was used to understand the mechanical resistance of the core of the prosthesis and the potential bone fracture induced in the radius with simulated bone- resorption (Figure 2a). The critical level was estimated at the height for which the thickness of the core is the minimum (Figure 2b). Considered boundary conditions:. - Full-length prosthesis plus radius out of the cement block equal to 60mm (Figure 2a);. - Bone inside the cement equal to 60mm (Figure 2b);. - Load inclined 10° epiphysiary component (Figure 2c);. - Radius with physiological or osteoporotic bone conditions;. - Load (concentrated in the sphere simulating full transmission from the articulation) of 500N or 1300N or 2560N. Figure 3 shows the results in terms of maximum stress on the core of the prosthesis and the risk of fracture (Schileo et al., 2008). According to the obtained results, the radial head prosthesis shows promising mechanical resistance despite of the simulated bone-resorption for all applied loads except for 2560N. The estimated mechanical limit for the material in use is 200MPa. The risk of fracture is in agreement with the experimental findings (Lacheta et al. (2019)), in fact bone starts to fail for the minimum reported failure load, but only for osteoporotic conditions. The presented FEA aimed at investigating the behavior of a femoral head prostheses made by 3D printing with simulated bone-resorption. The prosthesis shows to be a skilled solution even during accidental loads. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 27 - 27
11 Apr 2023
Puente Reyna A Schwiesau J Altermann B Grupp T
Full Access

The purpose of the study was to compare the mechanical properties, oxidation and wear resistance of a vitamin E blended and moderately crosslinked polyethylene for total knee arthroplasty (MXE) in comparison with clinically established polyethylene materials. The following polyethylene materials were tested: CPE (30 kGy e-beam sterilized), XLPE (75 kGy gamma crosslinked @ 100°C), ViXLPE (0.1 % vitamin E blended, 80 kGy e-beam crosslinked @ 100°C), and MXE (0.1 % vitamin E blended polyethylene, 30 kGy gamma sterilized). For the different tests, the polyethylene materials were either unaged or artificially aged for two or six weeks according to ASTM F2003-02. The oxidation index was measured based on ASTM F2102 at a 1 mm depth. Small punch testing was performed based on ASTM F2977. Mechanical properties were measured on unaged materials according to ASTM D638. Wear simulation was performed on a load controlled 3 + 1 station knee wear simulator (EndoLab GmbH, Thansau, Germany) capable of reproducing loads and movement of highly demanding activities (HDA) as well as ISO 14243-1 load profiles. The load profiles were applied for 5 million cycles (mc) or delamination of the polyethylene components. Medium size AS e.motion. ®. PS Pro (Aesculap AG, Tuttlingen, Germany) femoral and tibial components with a ZrN-multilayer surface, as well as Columbus. ®. CR cobalt-chrome alloy femoral and tibial components were tested. Particle analysis was performed on the serum samples of the ISO 14243-1 wear simulations based on ISO 17853:2011 and ASTM F1877. The analysis of the mechanical properties show that moderately crosslinked polyethylene (MXE) might be a superior material for total knee arthroplasty applications [Schwiesau et al. 2021]. The addition of vitamin E in a moderately crosslinked polyethylene prevented its oxidation, kept its mechanical characteristics, and maintained a low wear, even under a HDA knee wear simulation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 66 - 66
1 Dec 2019
Berberich C Sanz-Ruiz P
Full Access

Aim. There is an ongoing controversy whether the observed benefit of infection risk reduction by ALBC outweighs the risk of possible antimicrobial resistance development. Methods. The scientific & clinical literature in PubMed, Medline and Embase has been systematically reviewed with the keywords “antibiotic resistance”, “antibiotic loaded bone cement”, “local antibiotics”, “bacterial colonization” and “joint infection”. In total 28 relevant publications were found with the majority of them reporting laboratory results. Only 7 papers focused on clinical septic situations & patient data. Results. Although rare as consequence of the initially high drug concentrations in situ, experimental and clinical studies demonstrated survival of resistant bacteria on ALBC with subsequent bacterial re-colonisation of the biomaterial. This was most notable for coagulase-negative staphylococci (CoNS). Bacterial survival in presence of ALBC represents a selection process of already pre-existing high-level resistant mutants and not antibiotic resistance induction. The use of antibiotic combinations with gentamicin in bone cement is associated with a markedly lower risk of survival of resistant bacteria. This is particularly important in patients at high infection risks and in septic revision cases. There is no clinical evidence for a widespread increase of clinically important gentamicin resistancies in the orthopaedic ward because of routine use of ALBC. On an individual basis, the benefit of a lower infection probability with combined systemic & local antibiotic application should outweigh the risk of selecting pre-existing resistant bacteria. Each prevented infection case means that a complex and extended antibiotic therapy with risk of antibiotic resistance development over time has been avoided for a patient. In those cases where pre-existing resistant bacteria have survived the prophylactic exposure to antibiotics in bone cement, they remain in vast majority still susceptible to the clinically important antibiotics used for treatment of prosthetic joint infections. Conclusions. The benefit of a lower infection probability with ALBC should outweigh the risk of selecting resistant bacteria against the particular antibiotic used in bone cement. A trend towards broad resistance development which may complicate treatment of infection cases was not found


Aim. Bone and implant-associated infections caused by microorganisms that grow in biofilm are difficult to treat because of persistence and recurrence. Systemic administration of antibiotics is often inefficient because the poor vascularization of the site of infection. This issue has led to the development of biomaterials capable to locally deliver high doses of therapeutic agents to the injured bone with minimal systemic effects. In this context, calcium sulphate/hydroxyapatite (CS/HA) bone graft substitutes are widely used being safe, osteoconductive and resorbable biomaterials that can be easily enriched with consistent amounts of antibiotics. In this in vitro study, the capability of the eluted antibiotics to select the tested bacterial strains for antibiotic resistance was evaluated to confirm the safe use of the product. Method. S. aureus, S. epidermidis and P. aeruginosa isolated in our Institute from bone and joint infection with different resistance phenotypes were used. 6 × 2.5 mm CS/HA discs were generated by pouring the antibiotic loaded formulations in a mold and were used as a modified disk diffusion test. The resistance selection was evaluated by subculturing cells growing on the edge of the zone of inhibition (ZOI) for seven days. Minimum inhibitory concentrations (MICs) of gentamicin and vancomycin were determined by broth microdilution method before and after the selection of resistance assay. In addition, MICs were assessed after seven day passage on antibiotic free agar plates to evaluate if eventual decrease of antibiotic susceptibility was stable or only transient. Results. Commonly, no adaptation in presence of both CS/HA formulations was observed by analysing ZOI on agar medium. The kinetic of decrease of the ZOI was similar between the strains, with the exception of gentamicin resistant staphylococci in presence of gentamicin loaded CS/HA, which was faster with respect to the susceptible strains. Conclusions. The present study shows that elution of gentamicin and vancomycin from CS/HA bone graft substitutes did not induce a decrease in susceptibility to these antibiotics in an in vitro setting, suggesting the safe use of the product


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 309 - 309
1 Jul 2008
Neil M McAlinden G
Full Access

Introduction: In patients presenting with an infected hip arthroplasty first-line antibiotics at our institution are Flucloxacillin and Fucidic Acid. It was observed that many patients needed their antibiotic regime changed once sensitivities became known. This was because of resistance to the first-line antimicrobial agents. This raised the question ‘How frequent is Flucloxacillin and Fucidic acid resistance in prosthetic hip infection and is there a more appropriate first-line antibiotic?’. Method: A computerised search of the Belfast Orthopaedic Information System (BOIS) identified all cases of infected hip arthroplasty from October 2001 to April 2005. All microbiology results of these patients were obtained and analysed to determine the infecting organism, sensitivity and resistance to Flucloxacillin, Fucidic acid and Teicoplanin. Results: BOIS identified forty cases of infected hip arthroplasty, 35 primary arthroplasties and 5 revision arthroplasties. Of the 40 patients 36 had positive cultures, 3 had no growth and there was missing data on one patient. Flucloxacillin sensitivity occurred in 25% of patients with 58% resistance. With regard to Fucidic Acid sensitivity was 47 % with 44% resistance. There were no cases of Teicoplanin resistance. Teicoplanin sensitivity occurred in 78% of patients and with analysis by organism susceptibility sensitivity would measure 92% (8% were not tested against Teicoplanin). Discussion: Flucloxacillin resistance is greater than sensitivity in infected hip arthroplasty in this study group. Fucidic Acid sensitivity and resistance are roughly equal. There are no cases of Teicoplanin resistance in our study population and with analysis with respect to the causative organism Teicoplanin sensitivity reaches 92%. It could be suggested therefore that the first-line agents of Flucloxacillin and Fucidic acid are inappropriate and that Teicoplanin may be a better choice


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 19 - 19
1 Apr 2017
Corrado P Alan P Michael S
Full Access

Background. As the number of ceramic THR bearings used worldwide is increasing, the number of implants that experience off-normal working conditions, e.g. edge loading, third bodies in the joint, soft tissues laxity, dislocation/subluxation of the joint, increases too. Under all such conditions the bearing surfaces can be damaged, leading eventually to a limitation of the expected performances of the implant. Methods. We characterised the damage resistance of different bearing surfaces (alumina matrix composite BIOLOXdelta, alpha-alumina BIOLOXforte, zirconia 3Y-TZP, oxidized zirconium alloy Zr-2.5Nb, CoCr-alloy) by scratch tests performed following the European standard EN 1071–3:2005. Also the scratch hardness of same materials has been assessed. Results. The Lc1 value (i.e., the load for the onset of a scratch) measured for BIOLOXdelta is about fivefold the one measured for the oxidized zirconium alloy (OXZr) surface and about tenfold the Lc1 measured for the CoCr alloy. The height of ridges along the scratch edges due to plastic flow in the composite ceramic BIOLOXdelta are only 21% in height than in CoCr, and only a small fraction (0.04%) of the height of ridges measured on OXZr surfaces. The scratch hardness of the metal samples tested (CoCr, OXZr) results one order of magnitude lower than the ones of ceramics. This behavior is not influenced by of the presence of the coating on OXZr surface. Conclusions. The transformation toughened ceramics tested (BIOLOXdelta, 3Y-TZP) are the materials that exhibit the higher resistance to scratching. Ridges at scratch edges are lower in ceramics than in coated or uncoated metals. The result show the superior scratch resistance behavior of toughened ceramics for THR wear couples with respect to coated or bare alloys. Level of Evidence. Level 1


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 116 - 116
1 Apr 2019
Bock R Pezzotti G Zhu W Marin E Rondinella A Boschetto F McEntire B Bal BS
Full Access

Introduction. Support of appositional bone ingrowth and resistance to bacterial adhesion and biofilm formation are preferred properties for biomaterials used in spinal fusion surgery. Although polyetheretherketone (PEEK) is a widely used interbody spacer material, it exhibits poor osteoconductive and bacteriostatic properties. In contrast, monolithic silicon nitride (Si. 3. N. 4. ) has shown enhanced osteogenic and antimicrobial behavior. Therefore, it was hypothesized that incorporation of Si. 3. N. 4. into a PEEK matrix might improve upon PEEK's inherently poor ability to bond with bone and also impart resistance to biofilm formation. Methods. A PEEK polymer was melted and compounded with three different silicon nitride powders at 15% (by volume, vol.%), including: (i) α-Si. 3. N. 4. ; (ii) a liquid phase sintered (LPS) ß-Si. 3. N. 4. ; and (iii) a melt-derived SiYAlON mixture. These three ceramic powders exhibited different solubilities, polymorphic structures, and/or chemical compositions. Osteoconductivity was assessed by seeding specimens with 5 × 10. 5. /ml of SaOS-2 osteosarcoma cells within an osteogenic media for 7 days. Antibacterial behavior was determined by inoculating samples with 1 × 10. 7. CFU/ml of Staphylococcus epidermidis (S. epi.) in a 1 × 10. 8. /ml brain heart infusion (BHI) agar culture for 24 h. After staining with PureBlu™ Hoechst 33342 or with DAPI and CFDA for SaOS-2 cell adhesion or bacterial presence, respectively, samples were examined with a confocal fluorescence microscope using a 488 nm Krypton/Argon laser source. Images were also acquired using a FEG-SEM in secondary and backscattered modes on gold sputter-coated specimens (∼20–30Å). Hydroxyapatite (HAp) deposition was measured using a laser microscope. Raman spectra were collected for samples in backscattering mode using a triple monochromator using a 532 nm excitation source (Nd:YVO. 4. diode-pumped solid-state laser). Results. PEEK composites with 15 vol.% α-Si. 3. N. 4. , LPS ß-Si. 3. N. 4. , or the SiYAlON mixture showed significantly greater SaOS-2 cell proliferation (>600%, p<0.003, cf., Fig. 1(a)) and HAp deposition (>100%, p<0.003, cf., Fig. 1(b)) relative to monolithic PEEK. The largest increase in cell proliferation was observed with the SiYAlON composite, while the greatest amount of HAp was found on the LPS ß-Si. 3. N. 4. composite. Following exposure to S. epidermidis, the composite containing the LPS β-Si. 3. N. 4. powder showed one order of magnitude reduction in adherent live bacteria (p<0.003, cf., Fig. 1(c)) as compared to the PEEK monolith. It is interesting to note that the composite containing α-Si. 3. N. 4. exhibited the worst bacterial resistance (i.e., ∼100% higher than monolithic PEEK), suggesting that the bacteriostatic effectiveness of Si. 3. N. 4. bioceramics is apparently dependent upon the presence of selective sintering additives, viz. yttria and alumina. Conclusions. The addition of 15 wt.% of specific Si. 3. N. 4. powders to PEEK showed enhanced SaOS-2 cell adhesion, proliferation, and HAp deposition when compared to monolithic PEEK. These same composites also showed resistance to S. epi. adhesion and biofilm formation.. Although improvements in osteoconductivity have been previously observed by compounding or coating PEEK with HAp, titanium, or tantalum, these approaches did not provide anti-microbial properties. Compounding PEEK with Si. 3. N. 4. represents a significant advancement due to its ability to provide both improved bone apposition and resistance to biofilm formation. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 28 - 28
1 Feb 2020
Kamada K Takahashi Y Tateiwa T Shishido T Masaoka T Pezzotti G Yamamoto K
Full Access

Introduction. Highly crosslinked, ultra-high molecular weight polyethylene (HXLPE) acetabular liners inherently have a risk of fatigue failure associated with femoral neck impingement. One of the potential reasons for liner failure was reported as crosslinking formulations of polyethylene, increasing the brittleness and structural rigidity. In addition, the acetabular component designs greatly affect the mechanical loading scenario, such as the offset (lateralized) liners with protruded rim above the metal shells, which commonly induce a weak resistance to rim impingement. The purpose of the present study was to compare the influence of the liner offset length on the impingement resistance in the annealed (first generation) and vitamin E-blended (second-generation) HXLPE liners with a commercial design. Materials and Methods. The materials tested were the 95-kGy irradiated annealed GUR1020, and the 300-kGy irradiated vitamin E-blended GUR1050 HXLPE offset liners, which were referred to as “20_95” and “50E_300”, respectively. These liners had 2, 3, 4-mm rim offset, 2.45-mm rim thickness, and 36-mm internal diameter. Their rims were protruded above the metal rim at 2, 3, 4mm. Rim impingement testing was performed using an electrodynamic axial-torsional machine. The cyclic impingement load of 25–250N was applied on the rims through the necks of the femoral stems at 1Hz. The rotational torque was simultaneously generated by swinging the stem necks on the rims at 1Hz and its rotational angle was set at the range of 0–10˚. The percent crystallinity was analyzed on the as-received (intact) and impinged HXLPE acetabular rims by confocal Raman microspectroscopy. Results. The number of cycles to failure was dependent on the offset length (2, 3, 4-mm) in 20_95 and 50E_300 liners. Our results showed that the shorter the rim offset, the shorter the number of cycles to failure. In both HXLPEs, accumulation of impingement damages significantly decreased crystallinity in their near-surfaces, indicating the occurrence of crystallographic breakdown. In each offset length tested, the fracture always occurred much earlier in 50E_300 than 20_95. However, the magnitudes of the microstructural changes at the time of failure were much less in 50E_300 than 20_95. Conclusions. Although it is known that vitamin E blend into HXLPE can improve the fatigue resistance of HXLPE, the impingement resistance of 50E_300 was lower than vitamin-E free 20_95, indicating a larger negative contribution of high-dose radiation (300kGy) over a positive contribution of the vitamin E blend in 50E_300. Our results implied that the reduction of the protruded rim length in the offset liners may increase the neck-rim contact stresses at the time of impingement, causing a decrease in the fatigue durability. Therefore, if HXLPE offset liner is used, surgeons should take special care in maximizing the volume of the protruded lip section


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 318 - 318
1 Dec 2013
Gardner A Angibaud L Stroud N
Full Access

Introduction. Ideally, a patient receiving a unicondylar knee replacement will have fully functional anterior and posterior cruciate ligaments. When at least one of the cruciate ligaments is not fully functional, femoral and tibial implant contact position can potentially increase along the anterior-posterior (AP) axis. Where unicondylar implant wear testing typically uses AP resistance assuming fully functional cruciate ligaments, the authors used reduced AP resistance intended to simulate deficient cruciate ligaments. Methods. Optetrak Logic® Uni (Exactech Inc, Gainesville, FL USA) unicondylar test specimens featuring an all-UHMWPE tibial component and a cobalt chromium femoral component were used in this study. The system has a semi-constrained articular geometry. Testing was conducted at an independent testing facility (EndoLab GMBH, Thansau, Rosenheim, Germany). A four-station knee simulator was used (EndoLab knee simulator) with two unicondylar knee implants per station, giving a total of eight test specimens. Two different tibial fixation designs (keeled and peg) with identical articulating surfaces were tested. Tibial test specimens were 6 mm in thickness. Unloaded soak controls were stored in distilled water at 37°C. The test was conducted according to ISO 14243–1: 2009 [1]. Test specimens were immersed in calf serum (PAA GmBH, Cölbe, LOT B00111-5126) with a protein content of 20 g/l. Custom polyurethane molds allowed for individual component measurement. Per the ISO 14243-1, a 7% medial offset was incorporated into the set-up. The unicondylar knee implants were set at neutral position in extension. Tibial rotational restraint was 0.36 Nm/° and zero when the test specimen was within ± 6° of the reference position. This test was conducted with an AP resistance of 9.3N/mm to maximize AP displacement and simulate deficient cruciate ligaments. Typical unicondylar knee wear testing is conducted with an AP resistance of 44N/mm, which assumes functional cruciate ligaments. Results. Wear data was separated by component design (keeled and peg) as well as for medial and lateral placement [Table 1]. There was no significant difference between lateral components but there was for medial components. This difference could be due to the small sample size. Contact area of the UHMWPE tibial components was elliptical, with the longer portion along the AP axis. Mean wear rates were comparable to historical unicondylar knee systems tested at the same laboratory using the standard AP resistance (i.e., 44 N/mm). Discussion/Conclusion. This study demonstrated using an AP resistance 9.3 N/mm to simulate the presence of deficient cruciate ligaments in a unicondylar knee wear test produced similar wear rates and greater AP displacement when compared to testing using an AP resistance of 44 N/mm, which assumes functioning ligaments. This being said, design and material information about historical unicondylar knee systems tested are not known, so a direct comparison cannot be made. Performing unicondylar knee wear tests with reduced AP resistance could provide realistic wear information for devices implanted in patients without fully functioning cruciate ligaments