Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Bone & Joint Research
Vol. 7, Issue 2 | Pages 124 - 130
1 Feb 2018
Coric D Bullard DE Patel VV Ryaby JT Atkinson BL He D Guyer RD

Objectives. Pulsed electromagnetic field (PEMF) stimulation was evaluated after anterior cervical discectomy and fusion (ACDF) procedures in a randomized, controlled clinical study performed for United States Food and Drug Administration (FDA) approval. PEMF significantly increased fusion rates at six months, but 12-month fusion outcomes for subjects at elevated risk for pseudoarthrosis were not thoroughly reported. The objective of the current study was to evaluate the effect of PEMF treatment on subjects at increased risk for pseudoarthrosis after ACDF procedures. Methods. Two evaluations were performed that compared fusion rates between PEMF stimulation and a historical control (160 subjects) from the FDA investigational device exemption (IDE) study: a post hoc (PH) analysis of high-risk subjects from the FDA study (PH PEMF); and a multicentre, open-label (OL) study consisting of 274 subjects treated with PEMF (OL PEMF). Fisher’s exact test and multivariate logistic regression was used to compare fusion rates between PEMF-treated subjects and historical controls. Results. In separate comparisons of PH PEMF and OL PEMF groups to the historical control group, PEMF treatment significantly (p < 0.05, Fisher’s exact test) increased the fusion rate at six and 12 months for certain high-risk subjects who had at least one clinical risk factor of being elderly, a nicotine user, osteoporotic, or diabetic; and for those with at least one clinical risk factor and who received at least a two- or three-level arthrodesis. Conclusion. Adjunctive PEMF treatment can be recommended for patients who are at high risk for pseudoarthrosis. Cite this article: D. Coric, D. E. Bullard, V. V. Patel, J. T. Ryaby, B. L. Atkinson, D. He, R. D. Guyer. Pulsed electromagnetic field stimulation may improve fusion rates in cervical arthrodesis in high-risk populations. Bone Joint Res 2018;7:124–130. DOI: 10.1302/2046-3758.72.BJR-2017-0221.R1


Bone & Joint Research
Vol. 9, Issue 9 | Pages 613 - 622
1 Sep 2020
Perucca Orfei C Lovati AB Lugano G Viganò M Bottagisio M D’Arrigo D Sansone V Setti S de Girolamo L

Aims

In the context of tendon degenerative disorders, the need for innovative conservative treatments that can improve the intrinsic healing potential of tendon tissue is progressively increasing. In this study, the role of pulsed electromagnetic fields (PEMFs) in improving the tendon healing process was evaluated in a rat model of collagenase-induced Achilles tendinopathy.

Methods

A total of 68 Sprague Dawley rats received a single injection of type I collagenase in Achilles tendons to induce the tendinopathy and then were daily exposed to PEMFs (1.5 mT and 75 Hz) for up to 14 days - starting 1, 7, or 15 days after the injection - to identify the best treatment option with respect to the phase of the disease. Then, 7 and 14 days of PEMF exposure were compared to identify the most effective protocol.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 767 - 779
8 Dec 2021
Li Y Yang Y Wang M Zhang X Bai S Lu X Li Y Waldorff EI Zhang N Lee WY Li G

Aims

Distraction osteogenesis (DO) is a useful orthopaedic procedure employed to lengthen and reshape bones by stimulating bone formation through controlled slow stretching force. Despite its promising applications, difficulties are still encountered. Our previous study demonstrated that pulsed electromagnetic field (PEMF) treatment significantly enhances bone mineralization and neovascularization, suggesting its potential application. The current study compared a new, high slew rate (HSR) PEMF signal, with different treatment durations, with the standard Food and Drug Administration (FDA)-approved signal, to determine if HSR PEMF is a better alternative for bone formation augmentation.

Methods

The effects of a HSR PEMF signal with three daily treatment durations (0.5, one, and three hours/day) were investigated in an established rat DO model with comparison of an FDA-approved classic signal (three hrs/day). PEMF treatments were applied to the rats daily for 35 days, starting from the distraction phase until termination. Radiography, micro-CT (μCT), biomechanical tests, and histological examinations were employed to evaluate the quality of bone formation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 108 - 108
1 Nov 2018
Vinhas A Gonçalves A Rodrigues M Reis R Gomes M
Full Access

Unresolved inflammatory processes in tendon healing have been related to the progression of tendinopathies. Thus, the management of tendon injuries may rely on cell-based strategies to identify and modulate tendon inflammatory cues. Pulsed electromagnetic field (PEMF) has been approved by FDA for orthopedics therapies and has been related to a reduction in pain and to improve healing. However, the influence of PEMF in tendon healing remains largely unknown. Human tendon resident cells (hTDCs) were cultured in an inflammatory environment induced by exogenous supplementation of IL-1β and their response assessed after exposure to different PEMF treatments. This study demonstrates that IL-1β induced up-regulation of pro-inflammatory factors (IL-6 and TNFα) and extracellular matrix components (MMP−1, −2, −3) whereas reduces the expression of TIMP-1, suggesting IL-1β as a candidate inflammation model to study hTDCs response to inflammation cues. Moreover, in both homeostatic and inflammatory environments, hTDCs respond differently to PEMF treatment suggesting that cells are sensitive to magnetic field parameters such as strength (1.5 – 5mT), frequency (5–17Hz) and duration (10–50% duty cycle, dc). Among the conditions studied, PEMF treatment with 4mT/5Hz/50%dc suppresses the inflammatory response of hTDCs to the IL-1β stimulation, as evidenced by the decreases amount of IL-6, TNFα and downregulation of MMP-1, −2, −3 and COX-2, IL-8, IL-6, TNFα genes. These results demonstrate the potential of PEMF, in particular 4mT/5Hz/50%dc PEMF in treating tendon inflammation suppressing the inflammatory stimulation induced by IL-1β, which may be beneficial for tendon healing strategies


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 52 - 52
1 Nov 2018
Dolkart O Ferroni L Gardin C Barak S Piattelli A Zavan B
Full Access

Pulsed electromagnetic fields (PEMFs) have been considered a potential treatment modality for fracture healing. As bone fracture healing and osseointegration share the same biological events, the application of PEMF stimulation to facilitate the osseointegration process of orthopedic implants has been suggested. However, the mechanism of their action remains unclear. Mammalian target of rapamycin (mTOR) signaling may affect osteoblast proliferation and differentiation. This study aimed to assess the osteogenic differentiation of mesenchymal stem cells (MSCs) under PEMF stimulation and the potential involvement of mTOR signaling pathway in this process. PEMFs were generated by a novel miniaturized electromagnetic device (MED). Potential changes in the expression of mTOR pathway components, including receptors, ligands and nuclear target genes, and their correlation with osteogenic markers and transcription factors were analyzed. PEMF exposure increased cell proliferation, adhesion and osteogenic commitment of MSCs. Osteogenic-related genes were over-expressed following PEMF treatment. Our results confirm that PEMFs contribute to activation of the mTOR pathway via upregulation of the proteins AKT, MAPP kinase, and RRAGA, suggesting that activation of the mTOR pathway is required for PEMF-stimulated osteogenic differentiation. In summary, the findings of the present study revealed that MED-generated PEMFs stimulate osteogenic differentiation and the maturation of the adipose tissue-derived MSCs via activation of the mTOR pathways. Even though further research is required to determine an optimal stimulation timing and flux density both in-vitro and in-vivo, this study results may serve a source for an adjuvant therapy to improve orthopedic implant stability, longevity and enhance fracture healing


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 207 - 207
1 May 2012
Adie S Harris I Rae H Dao A Yong S
Full Access

Tibial shaft fractures have a high incidence of delayed and non-union, often requiring multiple procedures. Pulsed electromagnetic field (PEMF) stimulation is a safe and effective treatment for tibial non union but little is known about the efficacy of PEMF in preventing non-union in acute fractures. Between August 2005 and December 2008, eligible patients presenting at six major metropolitan hospitals with acute tibial shaft fractures (AO classification 4-2) were included. Participants were randomised by an independent allocation centre to identical active or inactive PEMF devices, both prescribed to be worn ten hours daily for twelve weeks. Baseline data were collected, and patients and surgeons were surveyed serially via post and/or phone at three, six and twelve months. Participants, data collectors and data analysts were blinded. The main outcome was any surgical intervention for delayed/non union. Data from 150 patients (76 active and 74 inactive) were available for analysis (12 month follow up 78%). There was no between-group difference in age, gender, mechanism of injury, open grade, smoking status, or compliance with the device (hours of use). Overall compliance was moderate (5.7 hours daily use). Fifteen of 76 (20%) of active device patients required surgery for delayed/non-union vs. 8 of 74 (11%) in the placebo group; odds ratio of surgery=2.03, p=0.13, 95% CI 0.80 to 5.12. An intention to treat analysis adjusted for open grade and hours the device was used showed an odds ratio of requiring surgery of 1.78 (p=0.24, 95% CI 0.68 to 4.64). A sub-group analysis of 80 compliant patients (defined a priori as a minimum average of six hours daily use) was performed. Nine of 35 (26%) patients with an active device required surgery for delayed/non-union vs. 3 of 45 (7%) in the placebo group; odds ratio of surgery=7.60 (p=0.017, 95% CI 1.43 to 40.24). Based on these unexpected initial results, PEMF stimulation does not prevent revision surgery for delayed/non-union in acute fractures of the tibial shaft


Bone & Joint Research
Vol. 9, Issue 6 | Pages 311 - 313
1 Jun 2020
Tsang SJ Morgan-Jones R Simpson AHRW


Bone & Joint 360
Vol. 3, Issue 5 | Pages 18 - 20
1 Oct 2014

The October 2014 Wrist & Hand Roundup360 looks at: pulsed electromagnetic field of no use in acute scaphoid fractures; proximal interphalangeal joint replacement: one at a time or both at once; trapeziometacarpal arthrodesis in the young patient; Tamoxifen and Dupytren’s disease; and endoscopic or open for de Quervain’s syndrome?


Bone & Joint 360
Vol. 1, Issue 1 | Pages 20 - 21
1 Feb 2012