Advertisement for orthosearch.org.uk
Results 1 - 20 of 4133
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 41 - 41
4 Apr 2023
Benca E Zderic I van Knegsel K Caspar J Hirtler L Fuchssteiner C Strassl A Gueorguiev B Widhalm H Windhager R Varga P
Full Access

Odontoid fracture of the second cervical vertebra (C2) is the most common spinal fracture type in elderly patients. However, very little is known about the biomechanical fracture mechanisms, but could play a role in fracture prevention and treatment. This study aimed to investigate the biomechanical competence and fracture characteristics of the odontoid process. A total of 42 human C2 specimens (14 female and 28 male, 71.5 ± 6.5 years) were scanned via quantitative computed tomography, divided in 6 groups (n = 7) and subjected to combined quasi-static loading at a rate of 0.1 mm/s until fracturing at inclinations of −15°, 0° and 15° in sagittal plane, and −50° and 0° in transverse plane. Bone mineral density (BMD), specimen height, fusion state of the ossification centers, stiffness, yield load, ultimate load, and fracture type according to Anderson and d'Alonzo were assessed. While the lowest values for stiffness, yield, and ultimate load were observed at load inclination of 15° in sagittal plane, no statistically significant differences could be observed among the six groups (p = 0.235, p = 0.646, and p = 0.505, respectively). Evaluating specimens with only clearly distinguishable fusion of the ossification centers (n = 26) reveled even less differences among the groups for all mechanical parameters. BMD was positively correlated with yield load (R² = 0.350, p < 0.001), and ultimate load (R² = 0.955, p < 0.001), but not with stiffness (p = 0.070). Type III was the most common fracture type (23.5%). These biomechanical outcomes indicate that load direction plays a subordinate role in traumatic fractures of the odontoid process in contrast to BMD which is a strong determinant of stiffness and strength. Thus, odontoid fractures appear to result from an interaction between load magnitude and bone quality


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2021
Morlock M Bätz J Beverland D Board T Lampe F Konow T
Full Access

The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) have rarely been studied due to the difficult quantification. Meanwhile registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant-size, -position, press-fit, contact area, primary stability and the effect of using a powered impaction tool. Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step and stem tilt, canal-fill-ratio, pressfit and contact area between bone and implant determined. 11 femur pairs were additionally tested for primary stability under cyclic loading conditions. Higher variations in press-fit and contact area between the surgeons for manual impactions compared to powered were observed. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion compared to smaller stems. Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The observed variations between the experienced surgeons may represent the acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations e.g. a stem tilt towards varus, might increase bone stresses and PPF risk


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 90 - 90
19 Aug 2024
Sakai T Kaneoka T Okazaki T Matsuki Y Kawakami T Yamazaki K Imagama T
Full Access

Recently, some smart media devices including portable accelerometers have been used to measure objective physical activity (OPA) after total hip arthroplasty (THA). The aim of this study was to longitudinally assess OPA changes in patients who underwent THA using a compact triaxial accelerometer and to investigate the impact of this recovery process on patient-reported outcomes. This prospective cohort study involved 163 consecutive patients who had unilateral osteoarthritis of the hip and were followed up for 12 months after THA. There were 132 women and 31 men with average age of 66 years. OPA was measured using a compact triaxial accelerometer preoperatively and at 1, 3, 6, and 12 months postoperatively. This study investigated the recovery process of OPA in four patient groups classified by the median of age and preoperative activity levels (younger and higher activity (YH), younger and lower activity (YL), older and higher activity (OH), and older and lower activity (OL)), and examined its impact on patient-reported outcomes, including forgotten joint score-12 (FJS-12). The target period for regaining preoperative activity levels was approximately 3 months for patients with lower preoperative activity, and about 6 months for those with higher preoperative activity. The OPA at 12 months postoperatively was higher in the patients with higher preoperative activity levels than in those with lower preoperative activity levels. In patients with higher preoperative activity levels, FJS-12 scores significantly increased between 6 and 12 months postoperatively (p=0.018). FJS-12 at 12 months postoperatively was best in YH (81.7±18.9), followed by YL (73.5±22.9), OH (73.2±17.4), and OL (66.3±21.8). Differences in the recovery process of postoperative activity levels impacted the duration required for improvement in FJS-12 scores. These results can serve as indicators for setting activity goals in patients undergoing THA


Bone & Joint Research
Vol. 9, Issue 9 | Pages 613 - 622
1 Sep 2020
Perucca Orfei C Lovati AB Lugano G Viganò M Bottagisio M D’Arrigo D Sansone V Setti S de Girolamo L

Aims. In the context of tendon degenerative disorders, the need for innovative conservative treatments that can improve the intrinsic healing potential of tendon tissue is progressively increasing. In this study, the role of pulsed electromagnetic fields (PEMFs) in improving the tendon healing process was evaluated in a rat model of collagenase-induced Achilles tendinopathy. Methods. A total of 68 Sprague Dawley rats received a single injection of type I collagenase in Achilles tendons to induce the tendinopathy and then were daily exposed to PEMFs (1.5 mT and 75 Hz) for up to 14 days - starting 1, 7, or 15 days after the injection - to identify the best treatment option with respect to the phase of the disease. Then, 7 and 14 days of PEMF exposure were compared to identify the most effective protocol. Results. The daily exposure to PEMFs generally provided an improvement in the fibre organization, a decrease in cell density, vascularity, and fat deposition, and a restoration of the physiological cell morphology compared to untreated tendons. These improvements were more evident when the tendons were exposed to PEMFs during the mid-acute phase of the pathology (7 days after induction) rather than during the early (1 day after induction) or the late acute phase (15 days after induction). Moreover, the exposure to PEMFs for 14 days during the mid-acute phase was more effective than for 7 days. Conclusion. PEMFs exerted a positive role in the tendon healing process, thus representing a promising conservative treatment for tendinopathy, although further investigations regarding the clinical evaluation are needed. Cite this article: Bone Joint Res 2020;9(9):613–622


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 28 - 28
1 Dec 2020
Tekin SB Karslı B Kurt V Öğümsöğütlü E
Full Access

Evidence that L5 transverse process fracture indicates pelvic instability is insufficient and controversial. Because of unstable pelvis fractures have high mortality rate, they require urgent treatment and good follow-up. The lumbar region is also affected by high-energy traumas in the pelvis region, which causes damage to the muscles and ligamentous structures that adhere to the lumbar transverse process. For this reason, L5 transverse process fracture is thought to be an indicator showing pelvic instability. However, our study shows that this is not like that. This study was carried out in order to investigate the effect of L5 transvers process fracture on pelvic instability and lack of sufficient data in the literature. Between 2017–2020, 86 Patient who were hospitalized and treated with a diagnosis of pelvic fracture were retrospectively studied in our clinic. Pelvic X-Ray and tomography was taken pre-op for all patient. Demographic features, pre-op and post-op hemoglobin counts, how many units of blood transfusion needed in total, fixation method, surgical intervention, presence of additional injury, mechanism of injury for all patient were analyzed and the patients were categorized by investigating L5 transvers process fracture in their tomography. Fractures of patients were classified according toTyle classification. The patients were divided into two main groups as who stabil and unstabil pelvic fractures and L5 transvers process fracture and without. On stabil pelvic fractures and unstabil pelvic fractures, in term of instability effects of L5 transvers process fractures and those without were investigated. Also, changes in preop and post op hemoglaobin counts were investigated in pelvis with and without L5 transvers process fractures. With these, in terms of blood transfusion need the patients were evaluated whether there was a difference between those with L5 transvers process fractures and who did not. Again, whether the blood transfusion was statistically different in stable and unstable pelvis fractures was among the parameters looked at. In statistical analysis, no correlation was found between pelvic instability and L5 transvers process fracture. (p=0,933) No statistically significant difference was found in the evalution of blood transfusion between those with and without L5 transvers process fractures. (P=0,409)When the same parameter was evaluated in terms of stability and instability of the pelvis, it was seen that stability did not significantly affect the need for blood transfusion. (P=0,989) Pre-op and post-op hemoglobin changes of the patients who with L5 transvers process fracture and without were also analized. İn the analysis performed, there was no significant difference in patients with and without L5 transvers process fractures on pre-op and post-op hemoglobin values. (p=0.771/p=0.118)However, Postoperative hemoglobin values were significanly lower in patient with L5 transvers process fracture compared to preopetative hemoglobin values. (p=0.001). L5 transvers process fracture is not a parameter to showing pelvic instability. Stabil and unstabil fractures did not change the need for blood transfusion. The literatüre still needs much more study on this topic


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 102 - 102
1 Nov 2021
Forriol F
Full Access

The knee joint has also a periarticular adipose tissue, which is known as Hoffa's fat pad (IPFP). IPFP has a dual function in the joint it reduces the concentration of Nitric Oxide, the release of glycosaminoglycans and the expression of MMP1 in the cartilage, but it also contains MSC and macrophages. Our hypothesis is that synovial fluid contains elements, not all of which are understood, which act as messengers and alter the “homeostasis” of the knee and the metabolism of all the cellular components of the joint, including the MSC of Hoffa's fat pad, thus making them another piece in the puzzle as far as OA of the knee is concerned. The IPFP of 37 patients with OA and 36 patients with ACL rupture were analyzed. Isolation, primary culture, and a functional and proteomic study of MSCs from IPFP were performed. Our results show that OA of the knee, in its more severe phases, also affects the MSC's of IPFP, which is a new actor in the OA degenerative process and which can contribute to the origin, onset and progression of the disease. A differential protein profile between OA and ACL patients were identified. Infrapatellar pad should be regarded as an adipose tissue with its own characteristics and it´s also able to produce and excrete important inflammatory mediators directly into the knee joint


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 18 - 18
1 Apr 2019
Lee P Chandratreya AP
Full Access

Background of study. Following the Montgomery ruling, consent is now a matter of law. The medical professionals have to show proof that risks and implications and material risks are explained to the patient and that they have accepted to go ahead with surgery. Materials and Methods. We devised a free web based programme (. www.consentplus.com. ) which introduces a documented checkpoint to the consent process in hip and knee replacement surgery. It enables reproducible high-quality bite-sized information delivery to patients and their families in an optimal environment. It utilises the flip classroom principle to facilitate dialogue between doctors and patients. It generates physical documentation to show patients’ knowledge and understanding of the risks; to produce a truly informed consent. Results. 1567 users completed the Consent PLUS process over 28 hospitals across the UK. 98.1% of users were satisfied with Consent PLUS in terms of quality of service and information delivered. Users’ self-rated knowledge increased by 29%, independent of age group, prior knowledge or check-point scores. Supportive documentation for 100% of the users, which facilitated the consent process but did not replace the consultation. 60% of users accessed the system via desktop computers, 23% via tablet and 17% via mobile phone. 55 consultant surgeons and 28 hospitals have been registered into the system by the users. 96.9% of users found Consent PLUS useful and 96.3% would recommend it to their friends. 92.6% would use it again. Conclusion. Consent PLUS can facilitate information delivery and improve patients’ understanding of the risks of surgery and its implications subjectively and objectively. Consent PLUS is a tool designed to enhance and facilitate the consent process, not to replace the current consent forms


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 69 - 69
1 Apr 2017
Barnouin L Günzel E
Full Access

Background. Based on decellularisation and cleaning processes of trabecular bone and fibrocartilage, an osteochondral allograft has been developed. Material. The chemical process, established thanks to bone and fibrocartilage data, included an efficient viroinactivation step. The raw material was a tibial plateau collected during knee arthroplasty, cut in cylinders strictly selected (>2mm cartilage height and total height between 10 and 16mm). The grafts were freeze-dried and gamma sterilised. Methods. Decellularisation and structure integrity were validated based on histological analysis, before and after treatment. Mesenchymal Stem Cells (MSC) proliferation in contact with the graft was evaluated to validate the biocompatibility. Biomechanics of the cartilage was studied to determine the compressive resistance before and after treatment. Proof of concept has been completed on femoral condyles in a rabbit model: osteochondral allografts of rabbit were prepared from femoral condyles, processed like human allografts and implanted in 6 femoral condyle defects of 4mm diameter and compared to 3 sham-operated sites. Rabbits were sacrificed at 12 weeks. Macroscopic evaluation and histological stainings were carried out to determine bone and cartilage reconstruction. Results. The stainings of processed grafts showed decellularisation, cleaning of bone, porosity of cartilage tissue, decrease in the aggrecan rate and preservation of type II collagen. MSC proliferated inside the trabecular bone and spread at the surface of the cartilage tissue after 3 weeks. Compressive resistance of cartilage before and after processing was similar to literature. Osteochondral rabbit defects were filled with bone and cartilage tissue, with total integration of bone and cartilage repair observed in two ways: cells spreading from lateral cartilage and MSC diffusing from subchondral plate. Conclusions. The decellularised biocompatible osteochondral allograft enhanced cartilage repair in an animal model. Two clinical trials are ongoing in talus and knee osteochondral lesions


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 116 - 116
1 Feb 2017
Lee J Hyung J Jeong H
Full Access

BACKGROUNDS. Total knee arthroplasty (TKA) using an imageless navigation is widely used in these days. Despite the usefulness of navigation-assisted TKA, there are still limitations of accuracy. From previous studies, many factors have been suggested as causes of the discordance between pre-op planning and post-op results. In Addition, Registration of reliable landmark is very important factor in navigation-assisted TKA, fundamentally. Nevertheless, current method of registration process is substantially affected by subjective preference of operators. Until now, However, there is no consensus about the optimal range of reference point. Moreover, the tolerance of imageless navigation system is still questionable. We investigated the effect of variation during the manual registration in this study. We compared the measured alignment and calculated plan of navigation system which were collected from repeated independent registration processes. METHODS. From 7 March 2016 to 13 May 2016, 44 patients (49 knees) underwent navigation assisted TKA with Orthopilot® Aesculap system. The subject group were severe osteoarthritis patients, they have evaluated radiographically and clinically before the operation. we excluded candidates who have shown very severe mal-alignment (>20 °) and metaphyseal bowing in Pre-op radiographic evaluation. All patients were followed for postoperative long axis film that could measure the correction angle, and followed clinically for functional score. Authors executed multiple registration trials in a single case, each trial was implemented by different surgeons (Senior surgeon JHJ and trainee LJH1, LJH2). At first, Senior surgeon (JHJ) start the operation from initial approach. Standard sub-vastus approach was applied to all-patients. After the procedure of joint exposure, each participating surgeon did the examination of knee anatomy and registered optimal point of his own. It was repeated three times (J,L1,L2) via imageless navigation system. Then, we collected the information of measured limb alignments and calculated plans of tibia cutting from navigation system. RESULTS. 33 knees were evaluated as Gr. 4 in Kellgren-Lawrence classification. The other 16 knees were Gr. 3. In repeated registration processes, patients who were scored Gr. 3 have shown no significant differences in mechanical limb alignments, both coronal and sagittal. There were also no significant differences in Gr. 4 patients, too. Initial tibia planning has shown the largest variance between medial and lateral cutting level (0.4 ± 1.3 mm, in neutral alignment). But, no statistical significance was observed. There is a tendency that the deviation of tibia planning has diminished gradually with the progression of this study. In radiographic evaluation, all cases have satisfactory limb alignments postoperatively. CONCLUSION. Our experiment suggest that variation of landmark registration alone couldn't have a significant effect on the calculated alignment of navigation system. In this study, we concluded that tolerable range of registration process for alignment calculation is relatively wide. Additionally, we think that the cutting depth is more vulnerable than alignment calculation, and it may need further study with more cases. Measured limb alignment is almost reliable in imageless navigation. Even though operators were not so experienced for the registration process


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 224 - 224
1 Jul 2008
Yoon WW Askin G Cole P Natali C
Full Access

Introduction: This study highlights the occurrence of significant post operative scoliosis associated with en-bloc resection of pancoast or superior sulcus tumours. We observed the rapid onset of high thoracic scoliosis following en-bloc resections. The Magnitude of the scoliosis, and predisposing surgical factors were reviewed in each of the cases implicating the role of the transverse process or its associated structures in the stabilization of the spine. Methods: Sixteen patients undergoing en-bloc resection for pancoast tumour were retrospectively reviewed. This was a single surgeon series where all patients had tumour resection over a 3 year period. The number of upper ribs and transverse processes resected were analysed and compared with the magnitude of scoliosis that developed over a follow up period of 2 years. Results: Four patients had significant resection of the transverse processes of T1 to T3. All of these patients developed scoliosis of rapid onset, convex to the side of the resection. Of the remaining 12 patients either no scoliosis developed, (6 of 12), or scoliosis of less than 12 degrees. Discussion: We observed rapid development of thoracogenic scoliosis in patients following lung tumour and chest wall resection. Our study shows that excision of the transverse processes is associated with subsequent development of an upper thoracic scoliosis. Preservation of the transverse process appears to be protective. Large resections can be performed with no subsequent scoliosis provided the transverse processes remain intact. This suggests that the transverse process or its associated structures have an important stabilizing function on the spine


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 70 - 70
1 Dec 2017
Strathen B Janß A Goedde P Radermacher K
Full Access

Demographic changes will increase the number of surgical procedures in the next years. Therefore, quality assurance of clinical processes, such as the reprocessing of surgical instruments as well as intraoperative workflows will be of increasing importance to ensure patient safety. Surgical procedures are often complex and may involve risks for the patient. For fixation of screws, e.g. in case of pedicle screws, osteosynthesis plates or revision joint replacement surgery implants, the application of defined torques may be crucial in order to achieve optimal therapeutic results and minimal complication rates. In many cases a subjective rating of the surgeon is necessary as no adequate instrumentation is available. With the same subjective feeling, hammering or screwing in are performed to implant e.g. the acetabular component in THA. Our actual work is dedicated to the implementation of a functional prototypes of sensor- integrated instruments for specific types of intervention (especially in traumatology) and the evaluation of the sensor integrated surgical instruments in combination with RFID technology for smart process optimisation in the operating room as well as for reprocessing of surgical instruments and surgical management in combination with a knowledge-based planning, control and documentation system. Complementary (preferably wireless) sensors such for instrument identification, tracking or more complex measurements such as forces, torques, temperature or impacts during surgery as well as during reprocessing of reusable instruments could enable computer network based quality assurance in a much broader and comprehensive manner. Within the framework of the OR.NET initiative we follow the approach to integrate wireless sensors for measurement of temperature, force-torque as well as inertial sensors for orientation and impact control, depending on the specific type of application for monitoring of workflows during surgery as well as during reprocessing of reusable instruments and devices. The integration of smart surgical instruments into an open networked operating room based on the open communication standard IEEE 11073 knowledge-based workflow system, can help to improve the process and quality management


Bone & Joint Research
Vol. 2, Issue 11 | Pages 245 - 247
1 Nov 2013
Sprowson AP Rankin KS McNamara I Costa ML Rangan A

The peer review process for the evaluation of manuscripts for publication needs to be better understood by the orthopaedic community. Improving the degree of transparency surrounding the review process and educating orthopaedic surgeons on how to improve their manuscripts for submission will help improve both the review procedure and resultant feedback, with an increase in the quality of the subsequent publications. This article seeks to clarify the peer review process and suggest simple ways in which the quality of submissions can be improved to maximise publication success. Cite this article: Bone Joint Res 2013;2:245–7


Aims. To compare the efficacy of decompression alone (DA) with i) decompression and fusion (DF) and ii) interspinous process device (IPD) in the treatment of lumbar stenosis with degenerative spondylolisthesis. Outcomes of interest were both patient-reported measures of postoperative pain and function, as well as the perioperative measures of blood loss, operation duration, hospital stay, and reoperation. Methods. Data were obtained from electronic searches of five online databases. Included studies were limited to randomised-controlled trials (RCTs) which compared DA with DF or IPD using patient-reported outcomes such as the Oswestry Disability Index (ODI) and Zurich Claudication Questionnaire (ZCQ), or perioperative data. Patient-reported data were reported as part of the systematic review, while meta-analyses were conducted for perioperative outcomes in MATLAB using the DerSimonian and Laird random-effects model. Forest plots were generated for visual interpretation, while heterogeneity was assessed using the I. 2. -statistic. Results. A total of 13 articles met the eligibility criteria. Of these, eight compared DA with DF and six studies compared DA with IPD. Patient-rated outcomes reported included the ODI and ZCQ, with mixed results for both types of comparisons. Overall, there were few statistically significant and no clinically significant differences in patient-rated outcomes. Study quality varied greatly across the included articles. Meta-analysis of perioperative outcomes revealed DF to result in greater blood loss than DA (MD = 406.74 ml); longer operation duration (MD = 108.91 min); and longer postoperative stay in hospital (MD = 2.84 days). Use of IPD in comparison to DA led to slightly reduced operation times (MD = –25.18 min), but a greater risk of reoperation compared to DA (RR = 2.70). Conclusion. Currently there is no evidence for the use of DF or IPD over DA in both patient-rated and perioperative outcomes. Indeed, both procedures can potentially lead to greater cost and risk of complications, and therefore, a stronger evidence base for their use should be established before they are promoted as routine options in patients with degenerative spondylolisthesis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 64 - 64
1 Apr 2018
DesJardins J Bales C Helms S
Full Access

Introduction. The accumulation of proteins and bacteria on implant surfaces is a critical concern in the biomedical field, especially with respect to the potential of biofilm formation on implant surfaces. Material surface wettability is often used as a predictor of potential colonization of specific bacterial strains. Surface roughness has also been shown to have a strong relationship with biofilm formation, as rougher surfaces tend to have a stronger affinity to harbor bacterial colonies. The modification of implant surfaces to impart a biofilm resistant layer can come at the expense of increasing surface roughness however, and it is therefore important to determine how the variables of wettability and roughness are affected by any new surface coating technologies. In the current work, a novel CoBlast (C) process that impregnates alumina (A) at 50 μm grit (5) or 90 μm grit (9) sizes, with the possible addition of polytetrafluoroethylene (P) onto titanium surfaces, combined with a plasma coating process called BioDep, that coats the surface with chitosan (X) with the possible addition of vancomycin (V), were evaluated for wettability and surface roughness to determine their potential as biofilm resistant treatments on implants. Materials and Methods. N=65 titanium alloy samples (n=5 for 13 sample modification types as described above and in the figure legends below) were analyzed for surface roughness and wettability. Following cleaning in ethanol, roughness testing (Ra, Rq, Rt and Rz, Wyko NT-2000 optical profilometer @ 28.7× magnification, FOV of 164×215 μm) at 5 different surface locations per specimen, and contact angle analysis was performed (2 μL water drops, KRUSS EasyDrop). Statistical differences between groups was determined using ANOVA. Results and Discussion. Figure 1a summarizes the roughness results, with significant roughening being observed with between surface blanks and all surface modification techniques, especially the CoBlasted 90 μm grit treatments. As expected, wettability (shown in Figure 1b) was significantly affected by PTFE modifications and also by the introduction chitosan and vancomycin. Conclusions. As can be seen from these results, changing the coating of a material can change the surface topography and the wettability of the surface, which can be beneficial for different applications. The results from this work show that the CoBlast and BioDep processes significantly affect both wettability and roughness, and that the benefits and potential drawbacks of each must be considered when assessing their potential for biofilm resistance. PTFE-coated samples would be best used when wanting to prevent a hydrophobic substance from binding to the material, while the alumina-coated or blank samples would be best used to prevent a hydrophilic substance from binding. In the future, nonpolar liquid wettability will be assessed to better mimic in-vivo conditions and to determine surface energy to be able to make better conclusions about the relationship between surface roughness and wettability. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2009
Mavrogenis A Liantis P Kontovazenitis P Papagelopoulos P Korres D
Full Access

The purpose of this study was to propose a new classification based on the structural, anatomical and biomechanical properties of the odontoid process, to evaluate the outcome and to suggest the adequate treatment in relation to the specific fracture type. The files of 97 patients with odontoid process fractures admitted to our institution were reviewed. The external and internal anatomy of the axis has been studied. The fractures were classified according to the proposed new classification. The method was tested for reliability and validity. Mean follow-up was 14 years. Intraobserver and interobserver agreement was excellent with intraclass correlation coefficients at levels of 0.98 and 0.85 respectively. Four types of odontoid process fractures are distinguished; type A fractures are avulsion fractures involving the tip of the odontoid; type B fractures are fractures of the neck between the lower edge of the transverse ligament and the line connecting the medial corners of the upper articular facets of the axis; type C fractures involve the area between the previously mentioned line and the base of the odontoid process (type C1) or extend to the body of the axis (type C2); type D fractures are complex fractures involving more than one level of the odontoid process. Classification of odontoid process fractures has to be reconsidered as novel imaging technology has shown new patterns of fractures. Computed tomography scan with image reconstruction is mandatory. The analysis of the imaging data in the present study justifies the new classification


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 33 - 33
1 Jan 2003
Echigoya N Harata S Ueyama K Okada A Yokoyama T
Full Access

Between 1982 and 2000, 37 cases of fractures of the odontoid process were treated at Hirosaki University Hospital. There were 16 females and 21 males, with an average age of 43.9 and 37.7 respectively. Twenty-three of 37 were type II and 14 were type III by the classification of Anderson and D’Alonzo. Eight of type II were old fractures. Nineteen of them were injured in traffic accidents, 9 in accidental falls from a height, 4 by falling down, 2 in lumbering accidents and 3 by unknown causes. Severe neurological disorders were recognized in 7, mild in 12 and 22 had no neurological disorders. Neurological disorders were correlated with SAC (space available for spinal cord) at C1-2. Twenty-two of type II (95.7%) and 10 of type III (71%) were treated surgically. Surgical methods were anterior screw fixation of the odontoid process in 7, anterior atlanto-axial joint fixation in 3, posterior atlanto-axial joint fixation in 5, posterior occipito-cervical fusion in 3, anterior and posterior combined fixation of the atlanto-axial joint in 2 and others in 2. Bone union was obtained in 18 (81.8%) of type II and 10 (100%) of type III by the primary operations. There was no nonunion in anterior screw fixation cases. Nonunion occured in one of type II (100%) and 2 of type III (50%) treated nonoperatively. Two of them were operated for nonunion. One of them remained nonunion by two additional operations. No case of nonunion showed neurological deterioration for 91.8 months after treatment on average. Anterior direct screw fixation of the odontoid process is superior to the other methods in the point of immobilization of the odontoid fragment without limiting the motion of the atlanto-axial joint. We recommend anterior direct screw fixation of the odontoid process as a first choice of the surgical method for fresh fractures of the odontoid process in cases with reduced fragments


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 39 - 39
1 Dec 2014
Maqungo S Kimani M Chhiba D McCollum G Roche S
Full Access

Purpose of study:. The presence of an L5 transverse process fracture is reported in many texts to be a marker of pelvis fracture instability. There is paucity of literature to support this view. Available studies have been performed on patients who were already known to have a pelvis fracture. No study has attempted to document the presence of this lesion in the absence of a pelvis fracture. Primary aim: To identify the correlation between the presence of a L5 transverse process fracture and an unstable pelvic ring injury. Secondary aim: To establish whether a L5 transverse process fracture can occur in the absence of a pelvis fracture. Methods:. We conducted a retrospective review of all CT scans performed in patients who presented to a Level 1 Trauma Unit for blunt abdomino-pelvic trauma between January 1, 2012 and August 28, 2013. A total of 203 patients met our inclusion criteria. Results:. Fifty four of these 203 patients (26%) sustained a pelvis fracture. Of these 54 patients 26 (48%) had an unstable fracture pattern according to the AO classification. Five of these 26 patients (19%) had an associated L5 transverse process fracture. Seven (12%) had an L5 transverse process fracture associated with a stable fracture pattern. Three patients (1.4%) had an isolated L5 transverse process fracture in the absence of a pelvis fracture. Conclusion:. This study confirms the association between the presence of a L5 transverse process fracture and an unstable pelvis fracture pattern. This injury is rarely seen in the absence of a pelvis fracture so its presence should alert the treating clinicians to the existence of a pelvis fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 19 - 19
1 Apr 2012
Aylott C Puna R Walker C Robertson P
Full Access

There is evidence that various anatomical structures have altered morphology with ageing, and anecdotal evidence of changing lumbar spinous process (LSP) morphology with age. This study aims to clarify the influence of age on LSP morphology, and on lumbar spine alignment. 200 CT scans of the abdomen were reformatted with bone windows allowing precise measurement of LSP dimensions and lumbar lordosis. Observers were blinded to patient demographics. Inter-observer reliability was confirmed. The smallest LSP is at L5. The male LSP is on average 2-3mm higher and 1mm wider than the female LSP. LSP height increases significantly with age at every level in the lumbar spine (P<10. -5. at L2). The LSPs increase in height by 2-5mm between 20-85 years of age (P<10. -6. ), which was as much as 31% at L5 (P<10. -8. ). Width increases proportionally more, by 3-4mm or greater than 50% at each lumbar level (P<10. -11. ). Lumbar lordosis decreases in relation to increasing LSP height (P<10. -4. ) but is independent of increasing LSP width (P=0.2). The height and width of the spinous processes increases with age. Increases in spinous process height are related to a loss of lumbar lordosis and may contribute to sagittal plane imbalance


Bone & Joint Research
Vol. 9, Issue 3 | Pages 99 - 107
1 Mar 2020
Chang C Jou I Wu T Su F Tai T

Aims. Cigarette smoking has a negative impact on the skeletal system, causes a decrease in bone mass in both young and old patients, and is considered a risk factor for the development of osteoporosis. In addition, it disturbs the bone healing process and prolongs the healing time after fractures. The mechanisms by which cigarette smoking impairs fracture healing are not fully understood. There are few studies reporting the effects of cigarette smoking on new blood vessel formation during the early stage of fracture healing. We tested the hypothesis that cigarette smoke inhalation may suppress angiogenesis and delay fracture healing. Methods. We established a custom-made chamber with airflow for rats to inhale cigarette smoke continuously, and tested our hypothesis using a femoral osteotomy model, radiograph and microCT imaging, and various biomechanical and biological tests. Results. In the smoking group, Western blot analysis and immunohistochemical staining revealed less expression of vascular endothelial growth factor (VEGF) and von Willebrand factor (vWF). The smoking group also had a lower microvessel density than the control group. Image and biochemical analysis also demonstrated delayed bone healing. Conclusion. Cigarette smoke inhalation was associated with decreased expression of angiogenic markers in the early bone healing phase and with impaired bone healing. Cite this article:Bone Joint Res. 2020;9(3):99–107


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 366 - 366
1 Sep 2012
Starks I Frost A Wall P Lim J
Full Access

The management of pelvic fractures remains a challenging problem for orthopaedic surgeons. The prompt recognition of unstable fracture patterns is important in reducing mortality and morbidity. It is perceived wisdom that a fracture of the transverse process of L5 is a predictor of pelvic fracture instability. There is a paucity of evidence in the literature to support this belief. The aim of our study was to determine if a fracture of the transverse process of L5 was a predictor of pelvic fracture instability. The Hospital Trauma database was reviewed. Between 2006 and 2009, 65 pelvic fractures were identified. They were classified according to the Burgess and Young classification. There were 37 stable and 28 unstable fractures. 14 patients had an associated fracture of the transverse process of L5; 9 were associated with an unstable fracture pattern. The odds ratio was 3; the relative risk 1.7. A fracture of the transverse process of L5 is associated with an increased risk of pelvic fracture instability. Its presence should alert the attending physicians to the possibility of an unstable injury