Objectives. In order to address acetabular defects,
Reconstruction of massive acetabular bone defects in primary and revision THA is challenging for reconstructive joint surgeons. The use of
This paper presents an ongoing review of the use of a wedge-shaped
Cementless biologic fixation surfaces on total joint replacement devices, such as those used in total hip and knee procedures, have evolved over the decades. Historically, various surfaces to allow bone ingrowth or ongrowth have been applied as a coating to a pre-formed solid metal substrate. As shown in Figure 1, from left to right, representative coating surfaces include sintered beads, diffusion-bonded fiber metal, and plasma sprayed titanium. In certain applications, tantalum
Highly
Failed ingrowth and subsequent separation of revision acetabular components from the inferior hemi-pelvis constitutes a primary mode of failure in revision total hip arthroplasty (THA). Few studies have highlighted other techniques than multiple screws and an ischial flange or hook of cages to reinforce the inferior fixation of the acetabular components, nor did any authors report the use of
Background. Failed ingrowth and subsequent separation of revision acetabular components from the inferior hemi-pelvis constitutes a primary mode of failure in revision total hip arthroplasty (THA). Few studies have highlighted other techniques than multiple screws and an ischial flange or hook of cages to reinforce the ischiopubic fixation of the acetabular components, nor did any authors report the use of
Aims. Severe, superior acetabular bone defects are one of the most challenging aspects to revision total hip arthroplasty (THA). We propose a new concept of “superior extended fixation” as fixation extending superiorly 2 cm beyond the original acetabulum rim with
Purpose:
Introduction. Cementless fixation in total knee arthroplasty has been proposed to offer advantages long-term once osteointegration has occurred as there is no substrate between the implant and the bone to fail. Radiostereometric analysis (RSA) is a useful tool to study fixation, but typically focused on early migration in the first two post-operative years. Few studies have looked at 10-year RSA migration in cementless fixation and those that have contain small numbers of subjects. The objective of this study was to compare implant migration and inducible displacement between cemented and cementless TKA at 10 years and to compare the 10-year migration to the 2-year data in an effort to validate the predictive modelling of RSA. Methods. Subjects who had previously participated in RSA migration studies with 2-year follow-up were recruited to return for a long-term follow-up exam, at least 10 years from their surgery. The implants under study included two cemented designs from two manufacturers and one
Metallosis is a combined chemical and toxic reaction which, if the wear of a metal implant is large, may cause extensive reaction of synovial membrane and thus triggering the loosening. We present a case of a 72 year-old man, who underwent to a cemented unicompartimental
Reliable, Durable, Easy to do, Solves major problems (bone loss, fixation) Availability, Disease transmission, Preparation difficulties, Long-term fixation/incorporationAdvantages of cones in revision TKA
Allograft concerns
Bone loss in total knee replacement has different configurations and most condylar and plateau deficits are well managed with prosthetic augmentation. Cones are rarely, if ever, necessary for these deficits and when entire femoral condyles are absent distal segmental replacement has worked well. In the setting of severe intramedullary bone loss on the tibial or femoral side cones may be used to support deficit bone. This is the one indication for the use of cones. The negative side of cones is that additional bone may be removed to fit a cone adequately. Many of the lesser areas of bone deficiency can be managed by the use of larger diameter stems for fixation. In a paper from Sandford et al. from the Vancouver group allograft results at 5 −10 year follow up had a similar success rate to cones. Rohl in a paper looking at cones and hybrid stems for bone loss in revision TKR found no difference in results at 3.5 years. Cones cost $4,000–6,000 each and their utilization has been increasing greatly. At Hospital for Special Surgery in 2015 18 cones were used, this has increased to over 150 in 2017 at a cost of $800,000. The overutilization of cones adds considerably to the cost of a revision procedure. Cones have a place in revision TKR for bone loss but it is limited and they should be used in the most extreme cases where bone augmentation is required for structural stability.
Restoration of bone loss is a major challenge of revision TKA surgery. It is critical to achieve of a stable construct to support implants and achieve successful results. Major bone defects of the femoral and/or tibia (AORI type IIB/III) have been reconstructed using impaction grafting, structural allografts or tumor prostheses. The major concerns with structural allograft are graft resorption, mechanical failure, tissue availability, disease transmission, considerable surgical skill required and prolonged operative time. Porous tantalum metaphyseal cones, are becoming the established method of choice to correct large bone defects with several recent studies demonstrating promising results. The high coefficient of friction of these implants provides structural support for femoral and tibial components. The high degree of porosity has excellent potential for bone ingrowth and long-term biologic fixation. Several published series, although with relatively small cohorts of patients, have reported good short-term results with trabecular metal cones for major femoral and tibial bony defects in revision TKA. In a recent study, 16 femoral and 17 tibial cones were reviewed at an average follow up of 33 months (range, 13 to 73 months) the mean Knee Society Score improved from 42 pre-operatively to 83 at last follow up with an improvement of the functional score from an average of 34 to 66 (p<0.0001). Radiological follow up revealed no evidence of loosening or migration of the constructs. No evidence of complications were noted in correlation with the use of trabecular metal cones.
The indications for cementless acetabular fixation have been broadened because our data supports the use of trabecular metal cups even when there's limited bleeding host bone contact. Trabecular metal augments have allowed us to use cementless cups when there is segmental loss of bone. Surgical Technique: The acetabular bed is prepared. If there is less medial bone stock than 2 mm, then morsellised allograft is impacted by reverse reaming. When reaming is complete and less than 50% bleeding host bone is available for cup stabilisation, then a trabecular metal cup is indicated. Trabecular augments are used if the trabecular cup trial is not stable, or if it is uncovered by 40% or more. The conventional augments come in different sizes to accommodate the diameter of the cup and the size of the defect. Larger defects are addressed with anterior and posterior column augments, and superior defects with figure of seven augments. Augments are fixed with at least two screws. The interface between the cup and the augments should be stable, but some surgeons place a very thin layer of cement between the augment and cup so micromotion does not occur while ingrowth is occurring. We have used trabecular metal augments in 46 acetabular revisions in conjunction with a TM cup. Thirty-four cases have at least 2 years follow-up with an average of 64.5 months. There has been 4 cup loosenings with 3 re-revisions.
Successful cementless acetabular designs require sufficient initial stability between implant and bone (with interfacial motions <150 μm) and close opposition between the porous coating and the reamed bony surface of the acetabulum to obtaining bone ingrowth and secondary stability. While prior generations of cementless components showed good clinical results for long term fixation, modern designs continue to trend toward increased porosity and improved frictional characteristics to further enhance cup stability. We intend to experimentally assess the differences in initial stability between a hemispherical acetabular component with a highly porous trabecular tantalum fixation surface (Continuum® Acetabular System, Zimmer Inc, Warsaw, IN)(Fig 1) and a hemispherical component with the new highly porous Trabecular Titanium® surface (Delta TT, Lima Corporate, Italy)(Fig 2) manufactured by electron beam melting.Introduction
Objectives
Segmental defects of the acetabulum are often encountered in revision surgery. Many times these can be handled with hemispherical cups. However when larger defects are encountered particularly involving the dome and/or posterior wall structural support for the cup is often needed. In the past structural allograft was used but for the last 12 years at our institution trabecular metal augments have been used in the place of structural allograft in all cases. This talk will focus on technique and mid-term results using augments in association with an uncemented revision shell. The technique can be broken down into 6 steps outlined below: 1. Exposure, 2. Reaming, 3. Trialing, 4. Augment Inserted, 5. Cup Insertion/Stabilization, 6. Trial Reduction/Liner Cementation A recent study was undertaken to assess the mid-term results of this technique. We prospectively followed the first 56 patients in whom these augments were utilised in combination with a trabecular metal acetabular component in our unit. Details of this study will be presented. The median follow up of the surviving patients was 110 months (range 88–128 months). Survivorship of the augments at 10 years was 92.2% (95% CI: 97.0–80.5%). In one case the augment was revised for infection and in 3 for loosening. In 1 of the revised cases there was a pre-operative pelvic discontinuity, the other 2 discontinuities in the series were not revised and remain asymptomatic. The results of the acetabular trabecular metal augments continue to be encouraging in the medium to long term with low rates of revision or loosening in this complex group of patients.Conclusions
Contemporary acetabular reconstruction in major acetabular bone loss often involves the use of
Highly
In primary total hip arthroplasty (THA) for patients with Crowe II or higher classes developmental dysplasia of the hip (DDH) or rapidly destructive coxopathy (RDC), the placement of the cup can be challenging due to superior and lateral acetabular bone defects. Traditionally, bone grafts from resected femoral heads were used to fill these defects, but bulk graft poses a risk of collapse, especially in DDH with hypoplastic femoral heads or in RDC where good quality bone is scarce. Recently,