Advertisement for orthosearch.org.uk
Results 1 - 20 of 87
Results per page:
Bone & Joint Research
Vol. 13, Issue 8 | Pages 392 - 400
5 Aug 2024
Barakat A Evans J Gibbons C Singh HP

Aims. The Oxford Shoulder Score (OSS) is a 12-item measure commonly used for the assessment of shoulder surgeries. This study explores whether computerized adaptive testing (CAT) provides a shortened, individually tailored questionnaire while maintaining test accuracy. Methods. A total of 16,238 preoperative OSS were available in the National Joint Registry (NJR) for England, Wales, Northern Ireland, the Isle of Man, and the States of Guernsey dataset (April 2012 to April 2022). Prior to CAT, the foundational item response theory (IRT) assumptions of unidimensionality, monotonicity, and local independence were established. CAT compared sequential item selection with stopping criteria set at standard error (SE) < 0.32 and SE < 0.45 (equivalent to reliability coefficients of 0.90 and 0.80) to full-length patient-reported outcome measure (PROM) precision. Results. Confirmatory factor analysis (CFA) for unidimensionality exhibited satisfactory fit with root mean square standardized residual (RSMSR) of 0.06 (cut-off ≤ 0.08) but not with comparative fit index (CFI) of 0.85 or Tucker-Lewis index (TLI) of 0.82 (cut-off > 0.90). Monotonicity, measured by H value, yielded 0.482, signifying good monotonic trends. Local independence was generally met, with Yen’s Q3 statistic > 0.2 for most items. The median item count for completing the CAT simulation with a SE of 0.32 was 3 (IQR 3 to 12), while for a SE of 0.45 it was 2 (IQR 2 to 6). This constituted only 25% and 16%, respectively, when compared to the 12-item full-length questionnaire. Conclusion. Calibrating IRT for the OSS has resulted in the development of an efficient and shortened CAT while maintaining accuracy and reliability. Through the reduction of redundant items and implementation of a standardized measurement scale, our study highlights a promising approach to alleviate time burden and potentially enhance compliance with these widely used outcome measures. Cite this article: Bone Joint Res 2024;13(8):392–400


Bone & Joint Open
Vol. 5, Issue 9 | Pages 729 - 735
3 Sep 2024
Charalambous CP Hirst JT Kwaees T Lane S Taylor C Solanki N Maley A Taylor R Howell L Nyangoma S Martin FL Khan M Choudhry MN Shetty V Malik RA

Aims. Steroid injections are used for subacromial pain syndrome and can be administered via the anterolateral or posterior approach to the subacromial space. It is not currently known which approach is superior in terms of improving clinical symptoms and function. This is the protocol for a randomized controlled trial (RCT) to compare the clinical effectiveness of a steroid injection given via the anterolateral or the posterior approach to the subacromial space. Methods. The Subacromial Approach Injection Trial (SAInT) study is a single-centre, parallel, two-arm RCT. Participants will be allocated on a 1:1 basis to a subacromial steroid injection via either the anterolateral or the posterior approach to the subacromial space. Participants in both trial arms will then receive physiotherapy as standard of care for subacromial pain syndrome. The primary analysis will compare the change in Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include the change in OSS at six and 12 months, as well as the Pain Numeric Rating Scale (0 = no pain, 10 = worst pain), Disabilities of Arm, Shoulder and Hand questionnaire (DASH), and 36-Item Short-Form Health Survey (SF-36) (RAND) at three months, six months, and one year after injection. Assessment of pain experienced during the injection will also be determined. A minimum of 86 patients will be recruited to obtain an 80% power to detect a minimally important difference of six points on the OSS change between the groups at three months after injection. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after a subacromial space steroid injection between the anterolateral versus posterior approach in patients with subacromial pain syndrome. This will help to guide treatment for patients with subacromial pain syndrome. Cite this article: Bone Jt Open 2024;5(9):729–735


Bone & Joint Open
Vol. 4, Issue 3 | Pages 205 - 209
16 Mar 2023
Jump CM Mati W Maley A Taylor R Gratrix K Blundell C Lane S Solanki N Khan M Choudhry M Shetty V Malik RA Charalambous CP

Aims. Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and range of motion. It is not currently known which is superior in terms of relieving patients’ symptoms. This is the protocol for a randomized clinical trial to investigate the clinical effectiveness of corticosteroid injection given as either a GHJ injection or SSNB. Methods. The Therapeutic Injections For Frozen Shoulder (TIFFS) study is a single centre, parallel, two-arm, randomized clinical trial. Participants will be allocated on a 1:1 basis to either a GHJ corticosteroid injection or SSNB. Participants in both trial arms will then receive physiotherapy as normal for frozen shoulder. The primary analysis will compare the Oxford Shoulder Score (OSS) at three months after injection. Secondary outcomes include OSS at six and 12 months, range of shoulder movement at three months, and Numeric Pain Rating Scale, abbreviated Disabilities of Arm, Shoulder and Hand score, and EuroQol five-level five-dimension health index at three months, six months, and one year after injection. A minimum of 40 patients will be recruited to obtain 80% power to detect a minimally important difference of ten points on the OSS between the groups at three months after injection. The study is registered under ClinicalTrials.gov with the identifier NCT04965376. Conclusion. The results of this trial will demonstrate if there is a difference in shoulder pain and function after GHJ injection or SSNB in patients with frozen shoulder. This will help provide effective treatment to patients with frozen shoulder. Cite this article: Bone Jt Open 2023;4(3):205–209


Abstract. Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients. Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced three-part fracture sustained in 16 patients, 24 had fracture dislocation and 30 sustained a four-part fracture of the proximal humerus. Patients were followed up for a mean of 26 months. The mean postoperative OSS at the end of the follow-up period was 32.4. The mean DASH score was 44.3. Tuberosity non-union occurred in 18 patients (12.6%), malunion in 7 patients (4.9%), heterotopic ossification in 4 patients (2.8%) and scapular notching in one patient. Anatomical reconstruction was achieved in 25 patients (17.5%), the influence of greater tuberosity healing on shoulder function could not be demonstrated. Heterotopic ossification seems to affect OSS and QDASH, we found statistically significant relation between HO and clinical outcomes. Patients with heterotopic ossification had significantly lower postoperative scores on DASH and OSS (P = .0527). Despite expecting good functional outcome with low complication rate after RSA, the functional outcome was irrespective of healing of the tuberosities


Bone & Joint Open
Vol. 4, Issue 2 | Pages 96 - 103
14 Feb 2023
Knowlson CN Brealey S Keding A Torgerson D Rangan A

Aims. Early large treatment effects can arise in small studies, which lessen as more data accumulate. This study aimed to retrospectively examine whether early treatment effects occurred for two multicentre orthopaedic randomized controlled trials (RCTs) and explore biases related to this. Methods. Included RCTs were ProFHER (PROximal Fracture of the Humerus: Evaluation by Randomisation), a two-arm study of surgery versus non-surgical treatment for proximal humerus fractures, and UK FROST (United Kingdom Frozen Shoulder Trial), a three-arm study of two surgical and one non-surgical treatment for frozen shoulder. To determine whether early treatment effects were present, the primary outcome of Oxford Shoulder Score (OSS) was compared on forest plots for: the chief investigator’s (CI) site to the remaining sites, the first five sites opened to the other sites, and patients grouped in quintiles by randomization date. Potential for bias was assessed by comparing mean age and proportion of patients with indicators of poor outcome between included and excluded/non-consenting participants. Results. No bias in treatment effect was observed overall for the CI site, or the first five sites, compared with the remaining sites in either trial. An early treatment effect on the OSS was observed for the first quintile of participants recruited to ProFHER only (clinically relevant difference of seven points). Selection bias for age was observed in the ProFHER trial only, with slightly younger patients being recruited into the study. Both trials showed some selection bias for markers of poor prognosis, although these did not appear to change over time. Conclusion. No bias in treatment effects overall were found at the CI or early sites set-up. An early treatment effect was found in one of the two trials, which was likely a chance effect as this did not continue during the study. Selection bias was observed in both RCTs, however this was minimal and did not impact on outcome. Cite this article: Bone Jt Open 2023;4(2):96–103


Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID). Results. The CAT algorithms accurately estimated 12-item questionnaire scores from between four and nine items. Scores followed a very similar distribution between CAT and full-length assessments, with the mean score difference ranging from 0.03 to 0.26 out of 48 points. Pearson’s correlation coefficient and ICC were 0.98 for each 12-item scale and 0.95 or higher for the OES subscales. In over 95% of cases, a patient’s CAT score was within five points of the full-length questionnaire score for each 12-item questionnaire. Conclusion. Oxford Hip Score, Oxford Knee Score, Oxford Shoulder Score, and Oxford Elbow Score (including separate subscale scores) CATs all markedly reduce the burden of items to be completed without sacrificing score accuracy. Cite this article: Bone Jt Open 2022;3(10):786–794


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 40 - 40
23 Feb 2023
Critchley O Guest C Warby S Hoy G Page R
Full Access

Glenoid bone grafting in reverse total shoulder arthroplasty (RTSA) has emerged as an effective method of restoring bone stock in the presence of complex glenoid bone loss, yet there is limited published evidence on efficacy. The aim of this study was to conduct an analysis of clinical and radiographic outcomes associated with glenoid bone grafting in primary RTSA. Patients who underwent a primary RTSA with glenoid bone grafting were retrospectively identified from the databases of two senior shoulder surgeons. Inclusion criteria included minimum of 12 months clinical and/or radiographical follow up. Patients underwent preoperative clinical and radiographic assessment. Graft characteristics (source, type, preparation), range of movement (ROM), patient-reported outcome measures (Oxford Shoulder Scores [OSS]), and complications were recorded. Radiographic imaging was used to analyse implant stability, graft incorporation, and notching by two independent reviewers. Between 2013 and 2021, a total of 53 primary RTSA procedures (48 patients) with glenoid bone grafting were identified. Humeral head autograft was used in 51 (96%) of cases. Femoral head allograft was utilised in two cases. Depending on the morphology of glenoid bone loss, a combination of structural (corticocancellous) and non-structural (cancellous) grafts were used to restore glenoid bone stock and the joint line. All grafts were incorporated at review. The mean post-operative OSS was significantly higher than the pre-operative OSS (40 vs. 22, p < 0.001). ROM was significantly improved post-operatively. One patient is being investigated for residual activity-related shoulder pain. This patient also experienced scapular notching resulting in the fracturing of the inferior screw. One patient experienced recurrent dislocations but was not revised. Overall, at short term follow up, glenoid bone grafting was effective in addressing glenoid bone loss with excellent functional and clinical outcomes when used for complex bone loss in primary RTSA. The graft incorporation rate was high, with an associated low complication rate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 35 - 35
10 May 2024
Bolam SM Wells Z Tay ML Frampton CMA Coleman B Dalgleish A
Full Access

Introduction. The purpose of this study was to compare implant survivorship and functional outcomes in patients undergoing reverse total shoulder arthroplasty (RTSA) for acute proximal humeral fracture (PHF) with those undergoing elective RTSA in a population-based cohort study. Methods. Prospectively collected data from the New Zealand Joint Registry from 1999 to 2021 and identified 7,277 patients who underwent RTSA. Patients were categorized by pre-operative indication, including acute PHF (10.1%), rotator cuff arthropathy (RCA) (41.9%), osteoarthritis (OA) (32.2%), rheumatoid arthritis (RA) (5.2%) and old traumatic sequelae (4.9%). The PHF group was compared with elective indications based on patient, implant, and operative characteristics, as well as post-operative outcomes (Oxford Shoulder Score [OSS], and revision rate) at 6 months, 5 and 10 years after surgery. Survival and functional outcome analyses were adjusted by age, sex, ASA class and surgeon experience. Results. Implant survivorship at 10 years for RTSA for PHF was 97.3%, compared to 96.1%, 93.7%, 92.8% and 91.3% for OA, RCA, RA and traumatic sequelae, respectively. When compared with RTSA for PHF, the adjusted risk of revision was higher for traumatic sequelae (hazard ratio = 2.29; 95% CI:1.12–4.68, p=0.02) but not for other elective indications. At 6 months post-surgery, OSS were significantly lower for the PHF group compared to RCA, OA and RA groups (31.1±0.5 vs. 35.6±0.22, 37.7±0.25, 36.5±0.6, respectively, p<0.01), but not traumatic sequelae (31.7±0.7, p=0.43). At 5 years, OSS were only significantly lower for PHF compared to OA (37.4±0.9 vs 41.0±0.5, p<0.01), and at 10 years, there were no differences between groups. Discussion and Conclusion. RTSA for PHF demonstrated reliable long-term survivorship and functional outcomes compared to other elective indications. Despite lower functional outcomes in the early post-operative period for the acute PHF group, implant survivorship rates were similar to patients undergoing elective RTSA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 72 - 72
1 Dec 2021
Komperla S Giles W Flatt E Gandhi MJ Eyre-Brook AE Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Shoulder replacements have evolved and current 4th generation implants allow intraoperative flexibility to perform anatomic, reverse, trauma, and revision shoulder arthroplasty. Despite high success rates with shoulder arthroplasty, complication rates high as 10–15% have been reported and progressive glenoid loosening remains a concern. Objectives. To report medium term outcomes following 4th generation VAIOS® shoulder replacement. Methods. We retrospectively analysed prospectively collected data following VAIOS® shoulder arthroplasty performed by the senior author between 2014–2020. This included anatomical (TSR), reverse(rTSR), revision and trauma shoulder replacements. The primary outcome was implant survival (Kaplan-Meier analysis). Secondary outcomes were Oxford Shoulder Scores (OSS), radiological outcomes and complications. Results. 172 patients met our inclusion criteria with 114 rTSR, 38 anatomical TSR, and 20 hemiarthroplasty. Reverse TSR- 55 primary, 31 revision, 28 for trauma. Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Trauma rTSR-Average post-operative OSS was 31.4 Anatomical TSR38 patients underwent primary anatomical TSR, 8 were revisions following hemiarthroplasty. In 16/38 patients, glenoid bone loss was addressed by bone grafting before implantation of the metal back glenoid component. Mean age at time of surgery was 68.3 years (53 – 81 years). Mean follow-up was 34 months (12 – 62 months). The average Oxford shoulder score improved from 14 (7–30) to 30 (9–48). There were 3 revisions (7.8%); two following subscapularis failure requiring revision conversion to reverse shoulder replacement and one for glenoid graft failure. Conclusions. The medium-term results of the VAIOS® system suggest much lower revision rates across multiple configurations of the system than previously reported, as well as a low incidence of scapular notching. This system allows conversion to rTSR during primary and revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 71 - 71
1 Dec 2021
Giles W Komperla S Flatt E Gandhi M Eyre-Brook A Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Background/Objectives. The incidence of reverse total shoulder replacement (rTSR) implantation is increasing globally, but apprehension exists regarding complications and associated challenges. We retrospectively analysed the senior author's series of rTSR from a tertiary centre using the VAIOS shoulder system, a modular 4th generation implant. We hypothesised that the revision rTSR cohort would have less favourable outcomes and more complications. Methods. 114 patients underwent rTSR with the VAIOS system, over 7 years. The primary outcome was implant survival. Secondary outcomes were Oxford shoulder scores (OSS), radiographic analysis (scapular notching, tuberosity osteolysis, and periprosthetic radiolucent lines) and complications. Results. There were 55 Primary rTSR, 31 Revision rTSR and 28 Trauma rTSR. Implant survival: Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Average post-operative OSS for the Trauma rTSR was 31.4 Radiological analysis and complications: Low incidence of scapular notching One hairline fracture below the tip of stem, noted incidentally, which required no treatment. One periprosthetic fracture after alcohol related fall. Treated non-surgically One joint infection requiring two-stage revision to rTSR. One dislocation noted at 2 year follow up. This patient had undergone nerve grafting within 6 months of rTSR for axillary nerve injury sustained during the original fracture dislocation. One acromial fracture with tibial and distal humeral fracture after a fall. Conclusions. The 4th generation modular VAIOS implant is a reliable option for various indications. The revision rTSR cohort had favourable outcomes with low complication rates. In this series, early-to-medium term results suggest lower revision rates and good functional outcomes when compared to published reports. We plan to monitor long-term implant survivorship and patient reported outcomes. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Bone & Joint Open
Vol. 2, Issue 1 | Pages 58 - 65
22 Jan 2021
Karssiens TJ Gill JR Sunil Kumar KH Sjolin SU

Aims. The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results. Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion. This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV. Cite this article: Bone Jt Open 2021;2(1):58–65


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 70 - 70
10 Feb 2023
Cosic F Kirzner N Edwards E Page R Kimmel L Gabbe B
Full Access

Proximal humerus fracture dislocations are amongst the most severe proximal humerus injuries, presenting a challenging management problem. The aim of this study was to report on the long-term outcomes of the management of proximal humerus fracture dislocations. Patients with a proximal humerus fracture dislocation managed at a Level 1 trauma centre from January 2010 to December 2018 were included. Patients with an isolated tuberosity fracture dislocation or a pathological fracture were excluded. Outcome measures were the Oxford Shoulder Score (OSS), EQ-5D-5L, return to work, and radiological outcomes. Complications recorded included further surgery, loss of position/fixation, non-union/malunion, and avascular necrosis. A total of 69 patients were included with a proximal humerus fracture dislocation in the study period; 48 underwent surgical management and 21 were managed with closed reduction alone. The mean (SD) age of the cohort was 59.7 (±20.4), and 54% were male. Overall patients reported a mean OSS of 39.8 (±10.3), a mean EQ-5D utility score of 0.73 (±0.20), and 78% were able to return to work at a median of 1.2 months. There was a high prevalence of complications in both patients managed operatively or with closed reduction (25% and 38% respectively). In patients undergoing surgical management, 21% required subsequent surgery. Patient reported outcome measures post proximal humerus fracture dislocations do not return to normal population levels. These injuries are associated with a high prevalence of complications regardless of management. Appropriate patient counselling should be undertaken before embarking on definitive management


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 9 - 9
20 Mar 2023
Desai T Hoban K Ridley D Jariwala A
Full Access

Sub-acromial decompression surgery (SAD) has been widely used to treat shoulder impingement. Its validity has been questioned in multi-centric clinical trials and dissatisfaction rates can be high (35%). It is difficult to predict which patients will benefit operatively as research into predictive factors is limited. The study aim was to conduct a root-cause analysis of reasons for dissatisfaction in a cohort of operated patients. All patients with SAD dissatisfaction in the local Upper Limb database between 2015-19 (n=74/296) formed our study cohort. Patients were scored on Oxford shoulder score (OSS), QuickDASH score, EQ-5D-3L (TTO+VAS) at weeks 26 and 52 post-operatively. Patients' clinical history, radiographs, consultation and operative notes were reviewed. 28% of patients were dissatisfied with surgery. Mean age =52.3±13.4 years with equal gender distribution. 87% were operated arthroscopically. 67% were in physically demanding occupations. There was a significant increase in OSS and QuickDASH at weeks 26 and 52 post-operatively (p<0.05), similar improvement was not noted in VAS pain score. Pain followed by stiffness were the main contributors of dissatisfaction. Multiple implicating factors were noted, the most common being acromio-clavicular joint arthritis (25.7%), suggesting concomitant pathologies as an additional cause for patient dissatisfaction. This is the first study to evaluate reasons for dissatisfaction following SAD. We noted high rates (28%) of dissatisfaction and a predilection for those involved in physically demanding occupations. We recommend meticulous pre-operative workup to identify co-existing pathologies and appropriate pre-operative counselling to improve outcomes in selected patients needing SAD following failure of conservative management


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 34 - 34
10 May 2024
Penumarthy R Turner P
Full Access

Aim. Clavicular osteotomy was described as an adjunct to deltopectoral approach for improved exposure of the glenohumeral joint. This study aims to present contemporary outcomes and complications associated with the routine use of clavicular osteotomy by a single surgeon in a regional setting within New Zealand. Methods. A retrospective case series of patients who have undergone any shoulder arthroplasty for any indication between March 2017 to August 2022. This time period includes all patients who had clavicular osteotomy(OS) and patients over an equal time period prior to the routine use of osteotomy as a reference group (N-OS). Oxford Shoulder Score (OSS) and a Simple Shoulder Test (STT) were used to assess functional outcomes and were compared with the reported literature. Operative times and Complications were reviewed. Results. 66 patients were included in the study. 33 patients in the OS group and 33 in the N-OS group. No difference in age, sex, indications for operative intervention and the surgery provided was identified. No significant difference in operative time between groups (N-OS 121 minutes; OS 128 minutes). No clinically significant difference was identified in the OSS (N-OS; mean 38 vs OS 39) or the STT (N-OS 8.3 vs OS 9). The outcomes scores of both groups are in keeping with published literature. Two post operative clavicle fractures, one prominent surgical knot occurred in the OS that required further surgical intervention. Two cases of localized pain over the clavicle and one case of the prominent lateral clavicle were reported in the OS group. Two cases of localized pain over clavicle reported in the N-OS group. Conclusion. Use of clavicular osteotomy is not associated with inferior patient reported. The osteotomy introduces specific risks, however, the study provides evidence that these complications are infrequent and avoidable. Surgeons should feel confident in using this adjunct when exposure to the shoulder is difficult


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 71 - 71
10 Feb 2023
Cosic F Kirzner N Edwards E Page R Kimmel L Gabbe B
Full Access

There is very limited literature describing the outcomes of management for proximal humerus fractures with more than 100% displacement of the head and shaft fragments as a separate entity. This study aimed to compare operative and non-operative management of the translated proximal humerus fracture. A prospective cohort study was performed including patients managed at a Level 1 trauma centre between January 2010 to December 2018. Patients with 2, 3 and 4-part fractures were included based on the degree of translation of the shaft fragment (≥100%), resulting in no cortical contact between the head and shaft fragments. Outcome measures were the Oxford Shoulder Score (OSS), EQ-5D-5L, and radiological outcomes. Complications recorded included further surgery, loss of position/fixation, and non-union/malunion. Linear and logistic regression models were used to compare management options. There were 108 patients with a proximal humerus fracture with ≥100% translation; 76 underwent operative management and 32 were managed non-operatively with sling immobilisation. The mean (SD) age in the operative group was 54.3 (±20.2) and in the non-operative group was 73.3 (±15.3) (p<0.001). There was no association between OSS and management options (mean 38.5(±9.5) operative vs mean 41.3 (±8.5) non-operative, p=0.48). Operative management was associated with improved health status outcomes; EQ-5D utility score adjusted mean difference 0.16 (95%CI 0.04-0.27, p=0.008); EQ-5D VAS adjusted mean difference 19.2 (95%CI 5.2-33.2, p=0.008). Operative management was further associated with a lower odds of non-union (adjusted OR 0.30, 95%CI 0.09-0.97, p=0.04), malunion (adjusted OR 0.14, 95%CI 0.04-0.51, p=0.003) and complications (adjusted OR 0.07, 95%CI 0.02-0.32, p=0.001). Translated proximal humerus fractures with ≥100% displacement demonstrate improved health status and radiological outcomes following surgical fixation. Patients with this injury should be considered for operative intervention


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 19 - 19
23 Feb 2023
Sandow M Cheng Z
Full Access

This paper presents an ongoing review of the use of a wedge-shaped porous metal augments in the shoulder to address glenoid retroversion as part of anatomical total shoulder arthroplasty (aTSA). Seventy-five shoulders in 66 patients (23 women and 43 men, aged 42 to 85 years) with Walch grade B2 or C glenoids underwent porous metal glenoid augment (PMGA) insertion as part of aTSA. Patients received either a 15º or 30º PMGA wedge (secured by screws to the native glenoid) to correct excessive glenoid retroversion before a standard glenoid component was implanted using bone cement. Neither patient-specific guides nor navigation were used. Patients were prospectively assessed using shoulder functional assessments (Oxford Shoulder Score [OSS], American Shoulder and Elbow Standardized Shoulder Assessment Form [ASES], visual analogue scale [VAS] pain scores and forward elevation [FE]) preoperatively, at three, six, and 12 months, and yearly thereafter, with similar radiological surveillance. Forty-nine consecutive series shoulders had a follow-up of greater than 24 months, with a median follow-up of 48 months (range: 24–87 months). Median outcome scores improved for OSS (21 to 44), ASES (24 to 92), VAS (7 to 0), and FE (90º to 140º). Four patients died, but no others were lost to follow-up. Apart from one infection at 18 months postoperatively and one minor peg perforation, there were no complications, hardware failures, implant displacements, significant lucency or posterior re-subluxations. Radiographs showed good incorporation of the wedge augment with correction of glenoid retroversion from median 22º (13º to 46º) to 4º. All but four glenoids were corrected to within the target range (less than 10º retroversion). The porous metal wedge-shaped augments effectively addressed posterior glenoid deficiency as part of aTSA for rotator cuff intact osteoarthritis, producing satisfactory clinical outcomes with no signs of impending future failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 63 - 63
4 Apr 2023
Rashid M Cunningham L Walton M Monga P Bale S Trail I
Full Access

The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Society Score (ASES), and quick Disabilities of the Arm, Shoulder, and Hand Score (quickDASH). Radiographic assessment included AP and axial projections. Patients were invited to attend a CT scan to confirm osseointegration. Statistical analysis utilised included descriptive statistics (mean and standard deviation) and paired t test for parametric data. 3 patients had revision surgery prior to the 2-year follow-up. Of these, 2/3 retained their custom glenoid components. 4 patients declined to participate. 5 patients were deceased at the time of commencement of the study. 21 patients were included in this analysis. The mean follow-up was 36.1 months from surgery (range 22–60.2 months). OSS improved from a mean 16 (SD 9.1) to 36 (SD 11.5) (p < 0.001). Constant-Murley score improved from mean 9 (SD 9.2) to 50 (SD 16.4) (p < 0.001). QuickDASH improved from mean 67 (SD 24) to 26 (SD 27.2) (p = 0.004). ASES improved from mean 28 (SD 24.8) to 70 (SD 23.9) (p = 0.007). Radiographic evaluation demonstrated good osseointegration in all 21 included patients. The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex patient cohort


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 8 - 8
1 Nov 2022
Bharmal A Gokhale N Curtis S Prasad G Bidwai A Kurian J
Full Access

Abstract. Background. To determine the long-term survival outcomes of Copeland Resurfacing Hemiarthroplasty (CRHA) performed by a single surgeon series. Methods. A retrospective cohort study which looked at patients who underwent CRHA over 6 years. Re-operations including revisions with component exchange taking place in our hospital and at local centres were reviewed. Oxford Shoulder Score (OSS) was used to assess their functional outcomes pre- and post-CRHA. Results. 80 CRHAs were performed in 72 patients between 2007 and 2013 with a mean follow-up of 6.5 years. The mean follow-up was 79 months (50–122). The primary indication for CRHA was osteoarthritis (76.3%), cuff tear arthropathy (16.3%), rheumatoid arthritis (5%) and post-trauma (1.3%). The mean pre-operative OSS was 16, which doubled following CRHA surgery. Fifteen patients underwent revision surgery due to ongoing glenoid pain with a mean revision time following primary CRHA being 49 months. Projected survival at the endpoints 5,7 and 10 years were 83, 81 and 79% respectively. Conclusion. This study provides us with a much longer average follow-up period in comparison to many other studies published. Previous studies, support resurfacing as a useful implant in reducing pain and improving function in the short-term; but this series demonstrates over the medium-term a relatively high revision rate of about 20% in comparison with other arthroplasty options, despite the revision rate seeming to plateau from the 5-year mark onwards


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 11 - 11
1 Mar 2020
Murray I Robinson P Goudie E Duckworth A Clark K Robinson C
Full Access

This prospective, randomized, controlled trial compares patient outcome after non-operative care versus open reduction and tunneled suspension device fixation (ORTSD) for grade III or IV acromioclavicular joint disruptions. Sixty patients aged between sixteen and thirty-five years with an acute grade III or IV AC joint disruption were randomized to receive ORTSD fixation or non-operative treatment. Functional assessment was conducted at six weeks, three months, six months, and one year using the Disabilities of the Arm, Shoulder and Hands (DASH), Oxford Shoulder Scores (OSS) and Short Form (SF-12). Reduction was evaluated using radiographs. Complications were recorded, and an economic evaluation performed. There was no significant difference in DASH or OSS at one year between non-operative and ORTSD groups (DASH score, 4.67 versus 5.63; OSS, 45.72 versus 45.63). Patients undergoing surgery had inferior DASH scores at 6 weeks (p<0.01). Five patients who failed non-operative management subsequently received surgery. Overall cost of treatment was significantly greater after ORTSD fixation (£796.22 vs £3359.73 (p<0.01)). ORTSD fixation confers no functional benefit over non-operative treatment at one year. While patients managed non-operatively generally recover faster, a significant group remain dissatisfied following non-operative treatment requiring delayed surgical reconstruction


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 96 - 97
1 Jan 2004
Cloke DJ Williams JR
Full Access

The aim of the present study is to compare the Oxford Shoulder Score (OSS), the Shoulder Pain and Disability Index (SPADI) and the SF36 in terms of their correlation and sensitivity to change in a group of patients with subacromial impingement. Patients attending a specialist shoulder clinic over a six-month period with a diagnosis of subacromial impingement completed the OSS, SPADI and SF36 on each of up to four attendances at six-week intervals, regardless of treatment. The data were analysed by creating scatter plots for each scoring system compared with each other, calculation of correlation coefficients, and calculating the effect size for each scale between subsequent visits (the difference in mean score divided by the standard deviation of the change in score for all individuals). This is a measure of sensitivity to change. Three-hundred and twenty-three sets of scores were obtained in 110 patients. Scores were recorded across the whole range of the OSS and SPADI in our population. Similarly, the physical functioning component of the SF 36 ranged from 0 to 100. However, total SF 36 scores ranged only from 478 to 831. There was good correlation between the OSS and SPADI scores (correlation coefficient = 0.86), although in 71% of observations the SPADI score was greater than the OSS when expressed as a percentage. The correlation between the OSS and SPADI was less good with the physical functioning component of the SF 36 (0.57 and 0.51 respectively), and worse with the total SF 36 (0.37 and 0.27 respectively) The OSS and SPADI showed good effect sizes (0.211 and 0.212) compared to the physical functioning and total SF 36 scores (0.104 and 0.063). The OSS and SPADI show close correlation between each other, and were similarly sensitive to change in a group of patients with impingement. However, the SF 36 shows a poor spread of scores and less sensitivity to change in this group. These data support the use of the OSS or SPADI in these patients