Patients with Neuromuscular disorders who have an arthritic hip joint present unique challenges. Due to inadequate bone stock, bony deformity and muscle imbalance there is a potentially increased risk of dislocation. These patients who have undergone conventional total hip replacement in the past, have been immobilised post-operatively in a hip spica to prevent post-op dislocation.
The use of modular systems adds versatility to the implant system, better restoration of hip biomechanics and lower inventory to the hospital. There have been reports of high metal ions, ARMD reactions and high implant failure rates due to potential problems from taper failures. These are more common in metal-on-metal hip replacements, but are being also reported in other bearings. Between 2001 and 2010, we performed 383 consecutive metal-on-metal (MoM) THRs through a posterior approach, using a BHR cup and Birmingham modular head with one of three different stems, all with 12/14 tapers. The earliest 104 hips employed a cemented MS30 stem (Zimmer GmbH, Winterthur, Switzerland). Subsequent 256 were Synergy and then 23 Anthology (both uncemented and both Smith and Nephew Orthopaedics, Memphis TN USA). There was no significant difference in the average age at surgery (65.4 years cemented vs 65.6 uncemented, p = 0.69), gender ratio (1.68 vs 1.89, p = 0.64), or bearing diameter (46.7 vs 46.8, p = 0.31). The earlier 203 Synergy stems were monoblock heads, while the remaining uncemented stems included a tapered sleeve in addition. There were 3 deep infections and 11 debris-related failures (overall revision rate 4.9%). The revision rate from aseptic failures (ALTR, effusion, osteolysis or component loosening) is 2.87%. Kaplan-Meier analysis of the entire cohort showed a 10-year implant survival of 96.8% with revision for any reason as the end-point. Cemented stems had a 100% survival at 10 years and 98.6% at 12 years. The uncemented stems had a 93.8% survival at 10 years. Within the uncemented group, the monoblocks had a 5 and 10-year survival of 99.0% and 96.4% respectively while the sleeved had 98.7% (5 years) and 96.3% (7 years) and 82.5% at 8 years. Retreival analysis showed clear evidence of taper failure. Our experience suggests taper failure leading to ALTRs and its sequelae. Others have reported ALTR type reactions in metal on polyethylene and ceramic on polyethylene bearing types as well in bearing diameters ranging from 28mm to 40mm. There is a need to improve taper design especially for use with
Pseudotumour formation is being reported with increasing frequency in failing metal-on-metal hip resurfacings and replacements. This mode of failure complication has also been reported with metal-on-polyethylene bearing bearings when it is usually associated with evidence of surface corrosion and no apparent wear at the head–neck taper. We present a case with evidence of taper wear and damage secondary to corrosion in an uncemented total hip replacement with a metal on polyethylene articulation (TMZF (Titanium, Molybdenum, Zirconium and Ferrous) Accolade® stem, Trident® HA coated acetabular shell, Low Friction Ion Treatment (LFIT™) Cobalt-Chrome anatomic head (40 mm), X3® polyethylene liner). Case. A 69 year old woman had a THR in 2008. A year later she started to complain of lateral based hip pain. Clinical examination and initial imaging indicated trochanteric bursitis and heterotopic bone formation. The symptoms became worse over the next 3 years and the patient was listed for exploration and excision of heterotopic bone. Surgical findings. Extensive pseudotumour was encountered deep to bursa and adherent to capsule. Abductors, external rotators and vastus lateralis were spared. There was minimal calcar osteolysis and marginal erosion in superior acetabulum. There was no obvious wear on the articulating surfaces of the femoral head and polyethylene inlay of the socket nor was there any evidence of neck-to-rim impingement or edge loading. There was visible blackening of both the taper and trunnion after femoral head removal. Results. Peripheral blood samples taken at the time of surgery recorded Cobalt 107 nmol/L, Chromium 9 nmol/L. Wear Measurements. These were performed on the articulating surfaces and the head taper using the RedLux Artificial Hip Profiler. No discernable wear was noted at the articulating surfaces. Qualitative 3-D surface mapping demonstrated a trunnion imprint on head taper of 10.1 mm in length. At the distal end of the taper this was incomplete indicating possible taper/trunnion incongruity. The majority of the material loss was demonstrated at the proximal end on the polar opposite side to incomplete imprint (Figure 1). Corrosion analysis. The head was sectioned for more detailed surface analysis of areas of interest. This demonstrated a polished region just inside the taper (G), followed by a deep pit (F), a region of extensive pitting (E) and running along the taper length were longitudinal needle like pits (D) indicative of a path of fluid ingress (D-G ref Fig 2.). These findings were more suggestive of crevice corrosion than mechanical wear. Histology. There was evidence of aseptic lymphocytic vasculitis-associated lesion (ALVAL) scoring 8 out of 10 (as per Campbell et al). With the continuing increase in the use of
Purpose: Several studies have shown elevated levels of metal ions in blood of patients with metal-on-metal (MM) total hip arthroplasty (THA). To minimize wear, the elastohydrodynamic theory suggests wear reduction for
Material loss at the head-stem taper junction may contribute to the high early failure rates of stemmed
Purpose. To determine whether there is a difference in the metal ion levels among three different metal-on-metal total hip systems: two monoblock
Introduction: Although good mid-term results have been reported with some metal on metal hip replacements, reported complications due to metal on metal (MOM) related reactions are a cause for concern. We have assessed the clinical outcome and MRI metallic artefact reduction sequence (MARS) findings in a consecutive series of patients with a
It has been speculated that high wear at the head-stem taper may contribute to the high failure rates reported for stemmed
Introduction: We hypothesised that a stemmed hybrid total hip replacement with a
Introduction. Although good mid-term results have been reported with some metal on metal hip replacements, reported complications due to metal on metal (MOM) related reactions are a cause for concern. We have assessed the early clinical outcome and results of routine metal artefact reduction MRI findings in a consecutive series of patients with a modern
Introduction: The aim of this study is to investigate whether MoM implants result in more chromosome aberrations and increased blood metal ions post-operatively when compared to MoP implants.
The reintroduction of hip resurfacing has raised the possibility of whether it could offer a better outcome in sporting and work activity after surgery compared to total hip replacement. Questionnaires were analysed from 125 total hip replacement (THR) and 108 hip resurfacing (HR) patients regarding participation in sport in the year after their surgery and returning to work they were employed at prior to their surgery. The two groups had similar average age (61 vs 60) and pre-operative Oxford hip scores (41 vs 38). Seventy-one of one-hundred and twenty-five THR patients compared to 76/108 HR patients participated in sporting activity in the year after their surgery. When including only patients that played sport before their surgery 54/75 THR and 66/83 HR patients returned to same sporting activity level after their surgery. Of the patients that worked before surgery 35/44 THR patients compared to 70/74 HR patients returned work to after their surgery. There is significant difference quantity of patients participating in sporting activity after HR and THR (fishers exact test, p value=0.04). However there is no significant difference in quantity of patients returning to sporting activity after HR or THR including only patients that played sport before their surgery (fishers exact test, p value=0.35). There is a significant difference in the quantity of patients returning to work activity after HR and THR (fishers exact test, p value= 0.02). HR has a better outcome in patients participating in sport after surgery compared to THR however there is no benefit for patients that are active pre-operatively. More patients return to work after HR than THR.
Large diameter metal on metal total hip arthroplasty (MOM THA) have shorter lengths of implantation due to increased failure caused by wear either at the articulating surface as well as the taper-trunnion interface. Taper-trunnion wear may be worse in large diameter MOM THA due the increased torque at the taper-trunnion interface. However little has been done to understand how differences in taper-trunnion geometry and trunnion engagement effects wear. The purpose of this study was to (1) measure the differences in taper geometry and trunnion engagement on the head-taper of 11/13, 12/14, and Type 1 taper designs and (2) to determine if taper geometry affects fretting, corrosion, and wear at the taper interface. We identified 54 MOM THA primary revision implants with head diameters greater than 36 mm from our retrieval archive. Patients' charts were queried for demographic information and pre-revision radiographs were measured for cup inclination and cup anteversion. To measure taper geometry and wear the head tapers were imaged using Redlux©. The point clouds obtained from this were analyzed in Geomagic©. Taper angles and contact length where the trunnion engaged with the female taper of the head-tapers were measured. The diameter of the taper at the most distal visual area of trunnion engagement was also measured. Best fit cones were fit to the unworn regions to approximate the pristine surface. Differences between the raw data and the unworn surface were measured and volumetric wear rates were calculated. Fretting and corrosion of the head-taper was graded using the Goldberg Scoring.Introduction:
Methods:
In a cross sectional cohort study three different metal on metal total hip systems were assessed. Two monoblock acetabular designs; the Durom socket (Zimmer, Warsaw, In) and the Birmingham socket (Smith and Nephew, Memphis, TN), and one modular metal on metal total hip system (Pinnacle, Depuy Orthopaedics, Warsaw, In) in patients who have received these implants in the our region. 56 patients were recruited in total. All patients were assessed clinically, radiologically and biochemically. Whole blood Cobalt, Chromium and titanium levels were tested. The median head size used in the Birmingham group was 52mm (Range 44mm to 56mm), and in the Durom group, 48mm (Range 42 to 54mm). The median head size used in the modular Pinnacle group was 40mm (Range 36–44mm). The blood metal ions levels in the larger non modular acetabular sockets were significantly raised compared to the Pinnacle group. For Co 1.95 µg/l and 2.70 µg/l in the Durom and Birmingham groups respectively compared to only 0.52 µg/l in the Pinnacle group (P< 0.001). Mean Cr levels were the same for the two monoblock systems, 1.9 µg/l compared to the Pinnacle sockets 1.2 µg/l (P< 0.001). Our study clearly demonstrates that there is a significant difference in metal ion levels in patients following a monobloc large head arthroplasty system compared to a smaller modular metal on metal hip arthroplasty. The smaller head size appears to produce less metal ions whilst at the same time a 36mm–44mm head size is large enough to increase hip stability and range of movement as well as decreasing the risk of impingement. In our practice we are no longer using this design and the safest strategy, when considering metal on metal bearings, is to use a modular, smaller head system such as the Pinnacle.
Introduction & aims. Total hip replacement is an excellent treatment option for people with late stage degenerative hip disease. In addition to marked reduction in pain and improvement in sleep, most people regain range of motion, physical ability and quality of life. This study aimed at the functional outcomes of
Large-diameter metal-on-metal (MoM) total hip arthroplasty (THA) has demonstrated unexpected high failure rates and pseudotumour formation. The purpose of this prospective cohort study is to report ten-year results in order to establish revision rate, prevalence of pseudotumour formation, and relation with whole blood cobalt levels. All patients were recalled according to the guidelines of the Dutch Orthopaedic Association. They underwent clinical and radiographical assessments (radiograph and CT scan) of the hip prosthesis and whole blood cobalt ion measurements. Overall, 94 patients (95 hips) fulfilled our requirements for a minimum ten-year follow-up.Aims
Methods
Purpose: Clinical studies still show significant variability in offset and leg length reconstruction after 28mmTHA. Precise restoration of hip biomechanics is important since it reduces wear and improves stability, abductor function and patient satisfaction. There is a tendency to increase offset and leg length to ensure stability of 28mmTHA. This may not be needed with the more stable LDHTHA and hip resurfacing implants, therefore potentially improving the precision of the hip reconstruction. The aim of this study was to verify this assumption. Method: Leg length and femoral offset were measured on standardized digital radiographs with a computer software in 254 patients (49 HR, 74 LDHTHA, 132 28mmTHA) with unilateral hip involvement and compared to the normal contralateral side. Results: Femoral offset was increased in 72% of 28mmTHA (mean +3.3mm), 56% of LDHTHA (mean +1.0mm) and 8% of HR (mean −3.2mm) (intergroup differences p<
0.05). The mean LLI was greater after 28mmTHA (+2,29mm) vs. (−0.45mm for LDHTHA and −1.8mm for HR). The percentage of patients with increased leg length >
4mm was greater for 28mmTHA (11%) compared to LDHTHA (2.7%) and HR (2%). Conclusion: The stability afforded by the
Corrosion at the taper interface between the femoral head and the femoral stem is well described in metal-on-polyethylene (MoP) hips but previously was undetermined in
Introduction: Better clinical outcome is generally reported after hip resurfacing when compared to conventional 28mmTHA. This may simply be the consequences of biased patient selection, patient perception or the advantageous use of larger diameter femoral heads in HR. The true clinical benefits of HR can only be assessed by comparison with LDH-THA in a blinded randomized study to eliminate/reduce those biases. This was the aim of the study. Materials and Methods: Charnley class A patients were randomized between HR or LDH-THA and kept blinded for one year. Clinical data, gait analysis, postural balance evaluations and functional tests were performed preoperatively, at 3, 6, 12 and 24 months postoperatively. 14 normal patients served as controls. Results: 24 patients were assigned to each group. There was no significant difference in WOMAC, SF-36, activity scores, and patient satisfaction. A slight advantage was observed for HR during the functional reach test (postural balance) and for LDH-THA during the step test (speed, strength and balance), all other tests showing no differences. Both groups quickly reached controls value for all tests by 3 months. Discussion: We have failed to demonstrate a clear difference in outcome between HR and LDH-THA. Both groups fully recovered quickly. The postulated clinical advantages of HR over 28mmTHA most likely result from using a
Purpose: Better clinical outcome is generally reported after hip resurfacing when compared to conventional 28mmTHA. This may simply be the consequences of biased patient selection, patient perception or the advantageous use of larger diameter femoral heads in HR. The true clinical benefits of HR can only be assessed by comparison with LDH-THA in a blinded randomized study to eliminate/reduce those biases. This was the aim of the study. Method: Charnley class A patients were randomized between HR or LDH-THA and kept blinded for one year. Clinical data, gait analysis, postural balance evaluations and functional tests were performed pre-operatively at 3, 6, 12 and 24 months postoperatively. Fourteen normal patients served as controls. Results: Twenty-four patients were assigned to each group. There was no significant difference in WOMAC, SF-36, activity scores, and patient satisfaction. A slight advantage was observed for HR during the functional reach test (postural balance) and for LDH-THA during the step test (speed, strength and balance), all other tests showing no differences. Both groups quickly reached controls value for all tests by 3 months. Conclusion: We have failed to demonstrate a clear difference in outcome between HR and LDH-THA. Both groups fully recovered quickly. The postulated clinical advantages of HR over 28mmTHA most likely result from using a