This study addresses a crucial gap in the knowledge of normative spinal growth in children. The objective of this study is to provide detailed and accurate 3D reference values for global and segmental spinal
Background. The knee joint morphology varies according to gender and morphotype of the patients. Objectives. To measure the
Creating cement keyholes (i.e. drilling simple holes in cancellous bone to allow cement filling) is a practice used in multiple scenarios in orthopaedic surgery to ensure improved fixation between the bone-cement interface and as such between bone and prosthesis. It is most commonly used in hip arthroplasty to secure fixation of the cup to the acetabulum by drilling keyholes in acetabulum. However very little research has been conducted into what the
Total knee replacement has proven to be a very successful procedure. However, problems have been encountered in fitting standard femoral implants to distal femurs using various popular total knee replacement systems. Authors observed that difficulties matching femoral components with distal femurs most frequently occurred in female patients. In practice, as far as femoral sizing is concerned, women are just treated as small men. Despite an extensive English literature search, only a limited number of studies addressing the gender differences in distal femurs proportions were identified. In view of our experiences, we hypothesize that 1) Anterior-posterior (AP)
Non-cemented components have traditionally employed several possible features, among them a stem and/or collar, to achieve proper alignment and initial implant stability within the proximal femoral cavity. The advent of MIS has stimulated an interest in reducing the
Comprehensive anthropometric information is essential to avoid patella-related complications after TKA. We compared the anthropometric patellar
The use of intramedullary column screws in the treatment of acetabular fractures is becoming more widely utilized. The development of percutaneous methods to insert these screws under image intensifier guidance is one of the main reasons for their increased use. Few groups are navigating insertion of these screws. The available screws are cannulated 6.5–8 mm screws. Most surgeons prefer using 3.2 mm guide wires to reduce deflection. With a shank diameter of 4.5 mm, 3.2 mm cannulation significantly weakens the screws. We postulated that both columns, specially the posterior column can accommodate larger screw diameters which will increase the stability of fixation allowing earlier full weight bearing. The currently used screws were designed for fixation of femoral neck fractures. As percutaneous fixation of acetabular fractures is a growing area of interest, this warrants designing suitable screws with larger diameters. Eight CT scans of the adult pelvis –performed for non fracture related indications-, were studied (7 females, 1 male). We found that the anatomical cross-section of the columns is irregular but approximately triangular. The method we used to determine the largest diameter of a screw to fit each column was fitting cylinders in the columns. Robin’s 3D software was used to segment acetabula and convert the CT data into polygon mesh (stereolithography STL format) bone surfaces at an appropriate Hounsfield value. The resulting STL files were imported in Robin’s Cloud software, where polygon mesh cylinders of 10 mm diameter were fitted in each column. These cylinders were then manipulated to achieve best fit and their diameters were gradually increased to the biggest diameter which still fitted in the column. The mean diameters of the fitted cylinders were 10.8 mm (range: 10–13mm) and 15.2 mm (range 14–16.5mm) for the anterior and posterior columns respectively. To our knowledge, this is the first investigation to study the cross sectional
Aims: To investigate the optimal dimension interference screw for fixation of a tendon graft in a bone tunnel. Methods: A porcine model was developed to represent ACL reconstruction in the distal femur. A standard 8mm size pig flexor tendon graft was inserted into a standard 8mm bone tunnel. The screw
Pelvic incidence is as a key factor for sagittal balance regulation that describes the anatomical configuration of the pelvis. The sagittal alignment of the pelvis is usually evaluated in two-dimensional (2D) sagittal radiographs in standing position by pelvic parameters of sacral slope, pelvic tilt and pelvic incidence (PI). However, the angle of PI remains constant for an arbitrary subject position and orientation, and can be therefore compared among subjects in standing, sitting or supine position. Such properties also enable the measurement of PI in three-dimensional (3D) images, commonly acquired in supine position. The purpose of this study is to analyse the sagittal alignment of the pelvis in terms of PI in 3D computed tomography (CT) images. A computerised method based on image processing techniques was developed to determine the anatomical references, required to measure PI, i.e. the centre of the left femoral head, the centre of the right femoral, the centre of the sacral endplate, and the inclination of the sacral endplate. First, three initialisation points were manually selected in 3D at the approximate location of the left femoral head, right femoral head and L5 vertebral body. The computerised method then determined the exact centres of the femoral heads in 3D from the spheres that best fit to the 3D edges of the femoral heads. The exact centre of the sacral endplate in 3D was determined by locating the sacral endplate below the L5 vertebral body and finding the midpoint of the lines between the anterior and posterior edge, and between the left and right edge of the endplate. The exact inclination of the sacral endplate in 3D was determined from the plane that best fit to the endplate. Multiplanar 3D image reformation was applied to obtain the superposition of the femoral heads in the sagittal view, so that the hip axis was observed as a straight not inclined line and all anatomical structures were completely in line with the hip axis. Finally, PI was automatically measured as the angle between the line orthogonal to the inclination of the sacral endplate and the line connecting the centre of the sacral endplate with the hip axis. The method was applied to axially reconstructed CT scans of 426 subjects (age 0–89 years, pixel size 0.4–1.0 mm, slice thickness 3.0–4.0 mm). Thirteen subjects were excluded due to lumbar spine trauma and presence of the sixth lumbar segment. For the remaining subjects, the computerised measurements were visually assessed for errors, which occurred due to low CT image quality, low image intensity of bone structures, or other factors affecting the determination of the anatomical references. The erroneous or ambiguous results were detected for 43 subjects, which were excluded from further analysis. For the final cohort of 370 subjects, statistical analysis was performed for the obtained PI. The resulting mean PI ± standard deviation was equal to 46.6 ± 9.2 degrees for males ( This is the first study that evaluates the sagittal alignment of the pelvis in terms of PI completely in 3D. Studies that measured PI manually from 2D sagittal radiographs reported normative PI in adult population of 52 ± 10 degrees, 53 ± 8 degrees and 51 ± 9 degrees for 25 normal subjects aged 21–40, 41–60, and over 60 years, respectively [3], and 52 ± 5 degrees for a cohort of 160 normal subjects [4]. The PI of 47 ± 10 degrees obtained in our study is lower than the reported normative values, which indicates that radiographic measurements may overestimate the actual PI. Radiographic measurements are biased by the projective nature of X-ray image acquisition, as it is usually impossible to obtain the superposition of the two femoral heads. The midpoint of the line connecting the centres of femoral heads in 2D is therefore considered to be the reference point on the hip axis, moreover, the inclination of the sacral endplate in the sagittal plane is biased by its architecture and inclination in the coronal plane. On the other hand, the measurements in the present study were obtained by applying a computerized method to CT images that determined the exact anatomical references in 3D. Perfect sagittal views were generated by multiplanar reformation, which aligned the centres of the femoral heads in 3D. The measurement of PI was therefore not biased by acquisition projection or structure orientation, as all anatomical structures were completely in line with the hip axis. Moreover, the range of the PI obtained in every study (standard deviation of around 10 degrees) indicates that the span of PI is relatively large. It can be therefore concluded that an increased or decreased PI may not necessary relate to a spino-pelvic pathology.
The proximity of neural structures to the coracoclavicular ligaments limits the amount of coracoid process that can be harvested. The purpose of this study of 100 dry human scapulae was to define the anatomic limitations. We found the mean measurement of the horizontal arm of the coracoid process anterior to the conoid tubercle was 21.5 mm (SD 0.9 mm). In 10% of the scapulae, it was larger than 30 mm. In 66%, the posterior aspect of the conoid fused with the vertical ramus and the lateral lip of the suprascapular notch. This amount of coracoid appears to be large enough to expand the glenoid vault, and to hold two AO small fragment screws. It can be safely harvested if the conoid ligament is respected. Partial sacrifice of the trapezoid ligament is unavoidable, but does not compromise coracoclavicular stability. If the coracoid osteotomy is extended medial to the conoid tubercle it encroaches on the vertical ramus of the coracoid and can damage the suprascapular nerve. Posterior advancement of the osteotomy can extend onto the anterosuperior glenoid.
In this study x-ray calibration using the femoral head diameter as derived by an anatomic formula is compared to the standard technique of using a calibration ball and acetate type fixed magnification.
Aims. To identify the responsiveness, minimal clinically important difference (MCID), minimal clinical important change (MIC), and patient-acceptable symptom state (PASS) thresholds in the 36-item Short Form Health Survey questionnaire (SF-36) (v2) for each of the eight
The purpose of this study was to determine the incidence of graft-tunnel mismatch (GTM) when performing anatomic anterior cruciate ligament reconstruction (ACLR) using bone-patella tendon-bone (BPTB) grafts and anteromedial portal drilling. Beginning in November 2018, 100 consecutive patients who underwent ACLR by two sports fellowship-trained, orthopedic surgeons using BPTB autograft and anteromedial portal drilling were prospectively identified. The BPTB graft
Aims. Fracture-related infections (FRIs) are a devastating complication of fracture management. However, the impact of FRIs on mental health remains understudied. The aim of this study was a longitudinal evaluation of patients’ psychological state, and expectations for recovery comparing patients with recurrent FRI to those with primary FRI. Methods. A prospective longitudinal study was conducted at a level 1 trauma centre from January 2020 to December 2022. In total, 56 patients treated for FRI were enrolled. The ICD-10 symptom rating (ISR) and an expectation questionnaire were assessed at five timepoints: preoperatively, one month postoperatively, and at three, six, and 12 months. Results. Recurrent FRI cases consistently exceeded the symptom burden threshold (0.60) in ISR scores at all assessment points. The difference between preoperative-assessed total ISR scores and the 12-month follow-up was not significant in either group, with 0.04 for primary FRI (p = 0.807) and 0.01 for recurrent FRI (p = 0.768). While primary FRI patients showed decreased depression scores post surgery, recurrent FRI cases experienced an increase, reaching a peak at 12 months (1.92 vs 0.94; p < 0.001). Anxiety scores rose for both groups after surgery, notably higher in recurrent FRI cases (1.39 vs 1.02; p < 0.001). Moreover, patients with primary FRI reported lower expectations of returning to normal health at three (1.99 vs 1.11; p < 0.001) and 12 months (2.01 vs 1.33; p = 0.006). Conclusion. The findings demonstrate the significant psychological burden experienced by individuals undergoing treatment for FRI, which is more severe in recurrent FRI. Understanding the psychological
Introduction. A good anatomic fit of a Total Knee Arthroplasty is crucial to a good clinical outcome. The big variability of anatomies in the Asian and Caucasian populations makes it very challenging to define a design that optimally fits both populations. Statistical Shape Models (SSMs) are a valuable tool to represent the morphology of a population. The question is how to use this tool in practice to evaluate the morphologic fit of modern knee designs. The goal of our study was to define a set of bone geometries based on SSMs that well represent both the Caucasian and the Asian populations. Methods. A Statistical Shape Model (SSM) was built and validated for each population: the Caucasian Model is based on 120 CT scans from Russian, French, German and Australian patients. The Asian Model is based on 80 CT scans from Japanese and Chinese patients. We defined 7 Caucasian and 5 Asian bone models by using mode 1 of the SSM. We measured the antero-posterior (AP) and medio-lateral (ML)
Abstract. The lateral ligaments of the ankle composed of the anterior talofibular (ATFL), calcaneofibular (CFL) and posterior talofibular ligaments (PTFL), are amongst the most commonly injured ligaments of the human body. Although treatment methods have been explored exhaustively, healing outcomes remain poor with high rates of re-injury, chronic ankle instability and pain persisting. The introduction and application of tissue engineering methods may target poor healing outcomes and eliminate long-term complications, improving the overall quality of life of affected individuals. For any surgical procedure or tissue-engineered replacement to be successful, a comprehensive understanding of the complete anatomy of the native structure is essential. Knowledge of the
Aims. Periprosthetic proximal femoral fractures (PFFs) are a major complication after total hip arthroplasty (THA). Health status after PFF is not specifically investigated. The aim of this study is to evaluate the health status pattern over two years after sustaining a PFF. Methods. A cohort of patients with PFF after THA was derived from the Brabant Injury Outcomes Surveillance (BIOS) study. The BIOS study, a prospective, observational, multicentre follow-up cohort study, was conducted to obtain data by questionnaires pre-injury and at one week, and one, three, six, 12, and 24 months after trauma. Primary outcome measures were the EuroQol five-dimension three-level questionnaire (EQ-5D-3L), the Health Utility Index 2 (HUI2), and the Health Utility Index 3 (HUI3). Secondary outcome measures were general measurements such as duration of hospital stay and mortality. Results. A total of 70 patients with a PFF were included. EQ-5D utility scores were significantly lower on all timepoints except at six months’ follow-up compared to pre-injury. EuroQol visual analogue scale (EQ-VAS) scores at one month's follow-up were significantly lower compared to pre-injury. The percentage of reported problems at two years was higher for all
Recently, technologies to culture one or more cell types in three
Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon. Eight cadaveric elbows were used.