In late presenting
This study shows the efficacy of The Pavlik harness for the treatment of Development Dysplasia of Hip using ultrasonographic monitoring. Between March 1995 and February 2000 we treated 149 dysplastic hips in 117 babies. According to the Graf’s classification 90 were dysplastic type IIB, IIC,IID hips; 59 were dislocated Type IIIA, IIIB and IV hips. Babies were regularly monitored using ultrasound until the age of 26 weeks and radiographs there after for bony roof angle. The Pavlik harness was abandoned if there was persistent dislocation of hip at the end of 3 weeks of treatment. The average full time harness treatment was 12.2 ( range 6–20 ) weeks. The average follow up was 55 ( range 30–90 ) months. The harness failed to reduce 14 hips ( 9.5 % of total hips). These required arthrogram and closed or open reductions. Late presentation beyond 12 weeks and a higher grade on the Graf’s classification reduces the success rate of the pavlik harness treatment. Two cases continue to show a small femoral ossific nuclei at 30 months follow up. The hips treated successfully showed no significant difference in acetabular index from the normal values at follow up radiographs. We conclude that using our protocol, successful initial treatment of
The purpose of this study was to analyze the patellofemoral kinematics in neglected adult developmental dysplasia of the hip patients with patellofemoral symptoms and tried to clarify the affect of the severity of dislocation, the amount of limb length discrepancy, the deviation of mechanical axis and the changes in femoral anteversion on patellofemoral alignment. The dynamic patellofemoral CT results of 39 patients with DDH suffering from knee pain were reviewed. The mean age was 40.07 (range: 22–61). 14 of them were bilateral and 25 were unilateral neglected DDH patients. The CT results of 12 patients suffering from unilateral patellofemoral pain following the treatment of locked intramedullary nailing was taken as control group. In this patients atraumatic and asymptomatic normal site was taken as control group.Aim
Methods
There is no consensus regarding the optimum frequency of ultrasound for monitoring the response to Pavlik harness (PH) treatment in
Incidence of Congenital talipes equino varus [CTEV] is 1 to 2 per 1000 birth, Out of all cases 20% cases are Non-idiopathic. The management of non-idiopathic CTEV, however, continues to be challenging due to Rigidity, Poor skin condition, Bony changes, Vascularity and Associated congenital abnormalities. In recent literature, short term results of Ponseti method for correction of non-idiopathic CTEV have been encouraging. As Ponseti method decreases the severity of deformity and hence decreases the need for extensive surgery. The aim of current study is to evaluate the results of Ponseti method in Non-idiopathic CTEV. Total 7 children below the age of one year with Non idiopathic clubfoot presented to us in the duration of 2013 to 2015 who were treated by us. The cases included are Streeters Dysplasia with congenital constriction rings 3, Arthrogryposis multiplex congenita with
Revision total hip arthroplasty (THA) is a challenging scenario following complex primary THA for
Background. Revision total hip arthroplasty (THA) is a challenging scenario following complex primary THA for
INTRODUCTION:. Management of
Aim. The aim of this study is to assess the effectiveness of clinic based ultrasound screening by Orthopaedic surgeon for early diagnosis and treatment of
There are a growing number of younger patients with
Through the paediatric LCP Hip plating system (Synthes GmBH Eimattstrasse 3 CH- 4436 Oberdorff), the highly successful technique of the locking compression plate used in adult surgery, has been incorporated in a system dedicated to pediatrics. We are presenting the outcome of the paediatric LCP hip plating system used for a variety of indications in our institution. We retrospectively reviewed the notes and radiographs of all those children who have had Paediatric LCP Plate for the fixation of proximal femoral osteotomy and proximal femur fractures in our institution, between October 2007 and July 2010, for their clinical progress, mobilization status, radiological healing and any complications. Forty-three Paediatric LCP hip plates were used in forty patients (24 males and 13 females) for the fixation of proximal femoral osteotomies (n=40) and proximal femur fractures (n=3). The osteotomies were performed for a variety of indications including Perthes disease,
Aim: Many risk factors for DDH are well documented. This study was undertaken to investigate whether multiple pregnancy is a risk factor for
Purpose: The outcome of primary total hip arthroplasty (THA) after a previous paediatric hip disease was studied in data from the Norwegian Arthroplasty Register (NAR). Materials and Methods: 72,301 primary THAs were reported to the NAR for the period 1987 – February 2002. Of these, 5,459 (7.6%) were performed because of sequela after
Purpose: About 1% of the children are born with neonatal hip instability (NHI). By combining data from the Medical Birth Registry of Norway (MBRN) with that of the Norwegian Arthroplasty Register (NAR), the influence of NHI on the risk for total hip arthroplasty (THA) before 37 years of age are studied. Materials and Methods: Since 1967 medical data, included stability of the hips, on all new-borns in Norway (2 092 536 babies) have been compiled. Since 1979 all THA performed in Norway are reported to the NAR. Until 2004 85,120 primary THAs were registered, of these 492 were performed on patients under 37 years of age. These two national registries were linked by using the unique person identification number assigned to each inhabitant of Norway. Results: Of those 20 668 born with NHI (1%), 9 had received a THA before 37 years of age (43/100 000). Since only 18 of 100 000 new-borns without NHI had had THA, new-borns with NHI had 2,5 times increased risk for having a THA before they become 37 years. Of the 492 THA in patients younger than 37 years in the NAR, 101 THA (20.5%) were, according to the surgeon, operated because of
Introduction: The use of custom made CAD-CAM femoral stems in primary Total Hip Replacement allows preservation of valuable bone stock in anatomically challenging femora whilst optimising biomechanics and improving function. The custom prosthesis design and manufacturing process is carried out with the aid of computed tomography (CT), a system of tomographic image processing, a Computer–Aided Design (CAD) system and a Computer–Aided Manufacturing (CAM) system. Aim: To report seven year minimum follow up of a custom made and designed femoral component used in total hip replacement, focusing on clinical and radiographic evidence of failure. Methods: Patients who had an uncemented total hip arthroplasty, by one of the two senior authors, with a CAD-CAM hip between February 1993 and February 2000 were retrospectively studied. An independent observer evaluated all patients radiologically using Engh’s criteria of osteointegration and clinically using Harris and Oxford Hip Scores. Results: 85 patients (47 male, 38 female) (102hips) underwent THA for a variety of reasons between February 1993 and February 2000. Average age was 53.7 (25.4–91.5). Average follow up was 9.3 years (7–15). The aetiologies for THA were:
Objective: Considering the high incidence and misdiag-nostic rate of
Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear. Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.Aims
Methods
The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four.Aims
Methods