The purposes of this study were to evaluate the accuracy and feasibility of a robotic preparation for
In primary total hip arthroplasty (THA) for patients with Crowe II or higher classes developmental dysplasia of the hip (DDH) or rapidly destructive coxopathy (RDC), the placement of the cup can be challenging due to superior and lateral acetabular bone defects. Traditionally, bone grafts from resected femoral heads were used to fill these defects, but bulk graft poses a risk of collapse, especially in DDH with hypoplastic femoral heads or in RDC where good quality bone is scarce. Recently, porous metal augments have shown promising outcomes in revision surgeries, yet reports on their efficacy in primary THA are limited. This study retrospectively evaluated 27 patients (30 hips) who underwent primary THA using cementless cups and porous titanium
The Covid-19 pandemic restricted access to elective arthroplasty theatres. Consequently, there was a staggering rise in waiting times for patients awaiting total hip arthroplasty (THA). Concomitantly, rapidly destructive osteoarthritis (RDOA) incidence also increased. Two cohorts of patients were reviewed: patients undergoing primary THA, pre-pandemic (December 2017-December 2018) and patients with RDOA (ascertained by dual consultant review of pre-operative radiographs) undergoing THA after the pandemic started (March 2020 – March 2022). There were 236 primary THA cases in the pre-pandemic cohort. Out of the 632 primary THA cases post-pandemic, 186 cases (29%) had RDOA. Within this RDOA cohort, the pre-operative mean OHS, EQ5D3L and EQVAS (12.7, 10.5 and 57.6 respectively) were all poorer than in the pre-pandemic population (18.3, 9.4 and 66.7 respectively) (p<0.05). There was no significant difference between the RDOA and pre-pandemic cohort in Patient Reported Outcome Measures (PROMS) at 12 months, perhaps due to their ceiling effect. Within the RDOA cohort, 7 cases required
Major bone loss involving the acetabulum can be seen during revision THA due to component loosening, migration or osteolysis and can also occur as a sequela of infected THA. Uncemented porous ingrowth components can be used for reconstruction of the vast majority of revision cases, where smaller segmental or cavitary defects are typically present. But when stable structural support on host bone is lacking, highly porous metal
Major bone loss involving the acetabulum can be seen during revision THA due to component loosening, migration or osteolysis and can also occur as a sequela of infected THA. Uncemented porous ingrowth components can be used for reconstruction of the vast majority of revision cases, where smaller segmental or cavitary defects are typically present. But when stable structural support on host bone is lacking, highly porous metal
Major bone loss involving the acetabulum can be seen during revision THA due to component loosening, migration or osteolysis and can also occur as a sequela of infected THA. Uncemented porous ingrowth components can be used for reconstruction of the vast majority of revision cases, where smaller segmental or cavitary defects are typically present. But when stable structural support on host bone is lacking, highly porous metal
Tantalum is a pure metallic element and is attractive for use in orthopaedic implants because it is one of the most biocompatible metals available for implant fabrication. The potential advantages for the use of porous tantalum in total hip arthroplasty include:. excellent bone and tissue ingrowth observed histologically;. direct polyethylene intrusion into the metal substrate. This allows the elimination of any potential backside wear in the monoblock cup;. The two-piece design consist of a tantalum shell with screw holes for fixation into the dome of the ilium and posterior column. A polyethylene liner is cemented into the tantalum shell to eliminates backside motion. In addition,
Tantalum is a pure metallic element and is attractive for use in orthopaedic implants because it is one of the most biocompatible metals available for implant fabrication. The potential advantages for the use of porous tantalum in total hip arthroplasty include:. excellent bone and tissue in growth observed histologically;. direct polyethylene intrusion into the metal substrate. This allows the elimination of any potential backside wear in the monoblock cup;. The two-piece design consist of a tantalum shell with screw holes for fixation into the dome of the ilium and posterior column. A polyethylene liner is cemented into the tantalum shell to eliminates backside motion. In addition,
Introduction. Tantalum is a pure metallic element and is attractive for use in orthopaedic implants because it is one of the most biocompatible metals available for implant fabrication. The potential advantages for the use of porous tantalum in total hip arthroplasty include: 1) excellent bone and tissue ingrowth observed histologically; 2) direct polyethylene intrusion into the metal substrate. This allows the elimination of any potential backside wear in the monoblock cup; 3) The two-piece design consist of a tantalum shell with screw holes for fixation into the dome of the ilium and posterior column. A polyethylene liner is cemented into the tantalum shell to eliminates backside motion. In addition,
There has been a longstanding need for a structural biomaterial that can serve as a bone graft substitute or implant construct and is effective for fixation by bone ingrowth. A porous tantalum material was developed to address these issues. The purpose of this paper and presnetation is to describe the properties and 2 to 5 year clinical results of porous tantalum in various reconstructive orthopaedic procedures. Porous tantalum has been used to manufacture primary and revision acetabular cups,
The direct lateral (or anterolateral) approaches to the hip for revision THA involve detachment of the anterior aspect of the gluteus medius from the trochanter along with a contiguous sleeve of the vastus lateralis. Anterior retraction of this flap of gluteus medius and vastus lateralis and simultaneous posterior retraction of the femur creates an interval for division of gluteus minimus and deeper capsular tissues and exposure of the joint. To enhance reattachment of this flap of the anterior portion of the gluteus medius and vastus lateralis back to the trochanter, an oblique wafer of bone can be elevated along with the muscle off of the anterolateral portion of the trochanter. This bony wafer prevents suture pull out when large nonabsorbable sutures are used around or through the fragment and passed into the bone of the trochanteric bed for reattachment during closure. To prevent excessive splitting proximally into the gluteus medius muscle (and resulting damage to the superior gluteal nerve), it is often helpful to extend the muscle split further distally down into the vastus lateralis. This combined with careful elevation of the gluteal muscles off of the ilium (instead of splitting them) helps provide excellent and safe exposure of the entire rim of the acetabulum and access to the supracetabular region for bone grafting,
Objectives. In order to address acetabular defects, porous metal revision acetabular components and augments have been developed, which require fixation to each other. The fixation technique that results in the smallest relative movement between the components, as well as its influence on the primary stability with the host bone, have not previously been determined. Methods. A total of 18 composite hemipelvises with a Paprosky IIB defect were implanted using a porous titanium 56 mm multihole acetabular component and 1 cm
The endoprosthetic treatment of secondary osteoarthritis resulting from congenital hip dysplasia is difficult due to the small diameter of the acetabulum and the hypoplastic anterolateral bone stock. On the femoral side the increased femoral anteversion, insufficient femoral offset and proximal femoral deformities (mostly valgus deformities) as well as the small diameter and straight form of the intramedullary canal pose challenges. Careful preoperative planning is mandatory. The Crowe classification is usually used to describe these pathologies. In severe cases (Crowe 3 and especially Crowe 4) a shortening and derotating femoral osteotomy should be taken into account. Small acetabular components,
Introduction. Acetabular revision for cavitary defects in failed total hip replacement remains a challenge for the orthopaedic surgeon. Bone graft with cemented or uncemented revision is the primary solution; however, there are cases where structural defects are too large. Cup cage constructs have been successful in treating these defects but they do have their problems with early loosening and metalwork failure. Recently, highly porous cups that incorporate metal augments have been developed to achieve greater intra-operative stability showing encouraging results. Methods. Retrospective analysis of twenty-six consecutive acetabular revisions with Trabecular Titanium cups. Inclusion criteria included aseptic cases, adult patients, end-stage disease with signs of loosening, no trauma nor peri-prosthetic fractures. Data was obtained for patient demographics, Paprosky classification, use of bone graft, use of
We present the results of 228 consecutive Charnley low friction arthroplasties, inserted in 193 patients between July 1972 and December 1976. All hips were inserted by the posterior approach without trochanteric osteotomy. All patients were enrolled into a prospective study and pre-and post-operative findings recorded. This series was reviewed in 1985 and once again in 2002. The pre-and peri-operative findings are similar to contemporary series. Due to our stable population only two patients were lost to follow-up. Our survivorship results show a 10-year survival of 93%, 20-year survivorship of 84% deteriorating to a 30-year survival of 73%. Of the 26 hips revised 6 were for recurrent dislocations and these were satisfactorily stabilised using
Recurrent posterior dislocation is a recognised complication following primary total hip arthroplasty. Incidences of between 0.11% and 4.5% have been reported in the literature. Component revision is regarded as standard management of recurrent posterior dislocation. However, revision surgery is a major surgical procedure and is often unsuitable for elderly, frail patients. A congruent, ultra-high molecular weight polyethylene
Purpose:. Acetabular bone loss during revision total hip arthroplasty (THA) poses a challenge for reconstruction as segmental and extensive cavitary defects require structural support to achieve prosthesis stability. Trabecular metal (TM)
The use of 3D printing has become increasingly popular and has been widely used in orthopaedic surgery. There has been a trend towards an increasing number of publications in this field, but existing literature incorporates limited high-quality studies, and there is a lack of reports on outcomes. The aim of this study was to perform a scoping review with Level I evidence on the application and effectiveness of 3D printing. A literature search was performed in PubMed, Embase, and Web of Science databases. The keywords used for the search criteria were ((3d print*) OR (rapid prototyp*) OR (additive manufactur*)) AND (orthopaedic). The inclusion criteria were: 1) use of 3D printing in orthopaedics, 2) randomized controlled trials, and 3) studies with participants/patients. Risk of bias was assessed with Cochrane Collaboration Tool and PEDro Score. Pooled analysis was performed.Aims
Methods
Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips. In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).Aims
Methods