header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Content I can access

Trauma

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 45 - 45
1 May 2018
Jahangir N Umar M Rajkumar T Davis N Alshryda S Majid I
Full Access

Purpose of study

To review the treatment and outcomes of paediatric pelvic ring injuries in the UK

Methods and results

We performed a retrospective review of all pelvic fracture admissions to an English paediatric major trauma centre (MTC) from 2012 to 2016. A total of 29 patients were admitted with pelvic ring injuries with a mean age of 11 years (4- 16yrs). Road traffic accident was the mechanism in majority (72%), followed by fall from height (24%). Femoral shaft fracture was present in 5 (17%), head injury in 5 (17%), chest injuries in 5 (17%) and bladder injury in one child. 48% patients needed surgical procedures for fractures or associated injuries. We differentiated injuries according to the classification system of Torode and Zeig. 17% were Type A, 3% Type B, 48% Type C and 31% Type D. Almost all (93%) patients were treated conservatively. 51% of patients were allowed to mobilize full weight bearing after a period of bed rest. Non-weight bearing mobilization was recommended for fractures extending into the acetabulum, sacral fractures, unstable fracture patterns or associated fractures (neck of femur, femoral shaft and tibial shaft). Surgical fixation occurred in two patients. Both of these patients had significantly displaced Type D fractures. Only 44% of patients were back to sports at six months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 138 - 138
1 Sep 2012
Umar M Patil V Lewthwaite S
Full Access

Quality of cementation in the early postoperative period has been proven to be an indicator of long-term survival of the total hip arthroplasty. Cementation grading described by Barrack et al is widely used but has certain limitations. It is based upon second-generation cementation technique and has unacceptably high inter- and intra-observer variability due to its subjective evaluation method.

We are introducing a new grading system of quality of femoral cementation. It is based upon the ratio of the length of radiological lucency to the total length of cement-bone interface on both antero-posterior and lateral views. Because of its objective nature, it is likely to show reproducible results.

We recruited five observers of various grades of surgical experience (trainees to consultant). Each observer graded the quality of femoral cementation on immediate postop xrays twice (gap of atleast two weeks) of 30 primary hip arthroplasties, using Barrack's grading and a new cementation index measured by dividing the ength of Radiolucency along CBI by the total Length of CBI.

Statistical analysis was performed by SPSS v17.0. Inter-observer and Intra-observer variability was determined by Intraclass Correlation Coefficient for a two way mixed model.

New cementation index showed excellent agreement for both inter and intra-observer reliability with intraclass correlation coefficient of 0.79 and 0.82 respectively. On contrary, results of inter-observer reliability for Barrack's grading were poor with value of 0.20. intra-observer reliability was found to be fair with 0.55.

As evident from this study, it is a more reliable way of assessing the quality of cementation, with excellent agreement in both inter and intra-observer categories.