header advert
Results 1 - 9 of 9
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To

Aim

We report the results of a modified Fulkerson technique of antero-medialisation of the tibial tubercle, combined with microfracture or abrasion arthroplasty in patients under 60 with patello-femoral osteoarthritis.

Methods

All patients operated between September 1992 and October 2007 were reviewed by an independent observer in clinic or by postal questionnaire, using the Oxford Knee Score, Melbourne Patella Score and a Satisfaction Score. Only patients with Outerbridge Grade 3-4 osteoarthritis of the patello-femoral joint were included. They were assessed pre-operatively with plain x-rays, MRI scans (as well as tracking scans in the last 10 years) and arthroscopically. All patients with tracking scans showed lateral subluxation of the patella. The surgical procedure was a modification of Fulkerson's tibial tubercle osteotomy, with an advancement of 1-1.5cms and a medialisation of 1.5cms. The exposed bone of the patella and trochlea was drilled in the early cases and in the later cases an arthroscopic microfracture or abrasion using a power burr was carried out.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 102 - 102
1 May 2012
A. S B. A M. L A. E R. V
Full Access

Background

Leg length discrepancy (LLD) after intramedullary nailing of femoral shaft fractures is a common problem reported in up to 43% of cases. Comminuted fractures with radiographic loss of bony landmarks have an increased possibility of being fixed with unequal leg lengths.

Aims

The purpose of this report is to evaluate the efficacy of routinely obtaining a CT scanogram post-operatively on patients of comminuted femoral shaft fractures treated with intramedullary nailing and immediate correction of limb length inequality if indicated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 106 - 106
1 May 2012
A. S R. P S. M I. A
Full Access

Background

Correct positioning of the femoral component in resurfacing hip arthroplasty (RHA) is an important factor in successful long-term outcomes. The purpose of computer-assisted navigation (CAS) in resurfacing is to insert the femoral neck guide wire with greater accuracy and to help size the femoral component, thus reducing the risk of notching at the head and neck junction. Several recent studies reported satisfactory precision and accuracy of CAS. However, there is little evidence that CAS is useful in the presence of anatomical deformities of the proximal femur, which is frequently observed in young patients with secondary degenerative joint disease.

Aim

The purpose of this in vitro study was to determine the accuracy of an image-free RHA navigation system in the presence of angular deformity of the neck, pistol grip deformity of the head and neck junction and slipped upper femoral epiphysis deformity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 57 - 57
1 May 2012
K. M A. S
Full Access

Glenoid loosening is a major problem in total shoulder arthroplasty. Failure of osteointegration, osteolysis and loosening are potential problems with concerning reports of these complications with earlier metal back designs. CT scans have been reported as more accurate than plain x-rays in examining fixation of components. This study examines the medium term osteointegration of the SMR (Lima) metal back glenoid component. 20 consecutive patients operated on by the same surgeon (KM) were evaluated at a mean of 3 years 9 months (range 3-5 years) using CT analysis. Films were read by a musculoskeletal radiologist (AS). 8 zones were described and the interface graded as ‘osteointergrated’, ‘lucent zone < 1mm’, ‘lucent zone 1-2mm’, ‘lucent zone > 2mm osteolysis’. Loosening was defined as lucent line on all zones > 1mm or migration of implant.

No components were loose. All components were osteointegrated around the central peg. Osteointegration was observed in 85% of zones. 4% of the zones were graded as osteolysis, all in the one patient. This patient had osteolysis 4 years post-surgery with superior subluxation of the humeral head and polyethlylene and metal wear. The glenoid component was not loose at revision surgery. Problems with this technique of assessment include radiation exposure and artefact. Small lucent zones often had a well contoured margin suggesting that the component did not seat perfectly on the bone surface in these areas.

These results confirm that reliable medium term osteointegration does occur with the SMR metal back glenoid in anatomical total shoulder replacement. Osteolysis can occur and longer term follow up is ongoing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 123 - 123
1 May 2012
P. L A. S G. R D. B O. S A. G
Full Access

Introduction

Young, high-demand patients with large post-traumatic tibial osteochondral defects are difficult to treat. Fresh osteochondral allografting is a joint-preserving treatment option that is well-established for such defects. Our objectives were to investigate the long-term graft survivorships, functional outcomes and associated complications for this technique.

Methods

We prospectively recruited patients who had received fresh osteochondral allografts for post-traumatic tibial plateau defects over 3cm in diameter and 1cm in depth with a minimum of 5 years follow-up. The grafts were retrieved within 24 hours, stored in cefalozolin/bacitracin solution at 4°C, non-irradiated and used within 72 hours. Tissue matching was not performed but joints were matched for size and morphology. Realignment osteotomies were performed for malaligned limbs. The Modified Hospital for Knee Surgery Scoring System (MHKSS) was used for functional outcome measure. Kaplan-Meier survivorship analysis was performed with conversion to TKR as end point for graft failure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 171 - 171
1 May 2012
A. S A. P
Full Access

Background

In the UK 70,000 knee arthroplasties are performed each year. Although outcomes from knee arthroplasties are usually excellent, they can nevertheless lead to negligence claims. The aim of this study was to establish the incidence, cost and cause of negligence claims arising from knee arthroplasties.

Method

All claims made to the NHS Litigation Authority between 2003 and 2008, where the operation was knee arthroplasty, were included in this study. Data obtained from the NHS Litigation Authority were reviewed, coded and analysed. For negligence to have occurred, patients must have suffered harm as a result of substandard care. Hence the cause of negligence claims was analysed in terms of: (1) Substandard care and (2) Harm caused.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 163 - 163
1 May 2012
E. B I. S M. P C. D J-A S
Full Access

Background

Deciding how to allocate scarce surgical resources is a worldwide issue. These decisions are difficult when considering procedures aimed primarily at improving functional quality of life, such as lower extremity joint replacement (LEJR) surgery, and procedures perceived as life preserving which also have impacts on physical function, such as coronary artery bypass graft (CABG) surgery. Comparing functional outcomes of these two procedures may provide further evidence to guide resource allocation decisions.

Methods

We compared patient-reported functional outcomes following CABG and LEJR surgery using standardised, validated outcome metrics. A retrospective review of prospectively collected pre- and post-operative health related quality of life (SF-36) measures were conducted from 105 patients undergoing elective CABG and 105 elective LEJR surgery patients. Patients were matched based on gender and age.


Introduction

Rolando type base of thumb metacarpal fractures are potentially debilitating injuries, which can be difficult to manage because of their inherent instability. Malunion is associated with stiffness, pain and weakness of pinch grip. We aimed to assess the outcome of a simple technique for the treatment of this fracture using the principle of ligamentotaxis, with a static, 2-pin external fixator spanning the trapeziometacarpal joint. We present the results and functional outcomes of this technique.

Methods

A consecutive series of 8 patients (7 males, 1 female) with Rolando type intra-articular fractures of the base of the first metacarpal was retrospectively reviewed. All cases were performed by the senior author using a static, 2-pin Mini-Hoffman external fixator. Case notes and radiographs were reviewed, and patients' functional outcome assessed using the Quick Disability of Arm, Shoulder and Hand (Quick DASH) scoring system. Mean age of the group was 32.8 years (range 18.1-52.3 years). Mean follow-up was 2.7 years (range 3.5 months to 6.0 years).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 27 - 27
1 May 2012
M. P G. B A. S L. C M. S A. B P. C
Full Access

Orthopaedic cobalt chromium particles and ions can induce indirect DNA damage and chromosome aberrations in human cells on the other side of a cellular barrier in tissue culture. This occurs by intercellular signalling across the barrier. We now show that the threshold for this effect depends on the metal form and the particle composition.

Ionic cobalt and chromium induced single strand breaks at concentrations equivalent to those found in the blood of patients with well functioning metal on metal hip prostheses. However, they only caused double strand breaks if the chromium was present as chromium (VI), and did not induce chromosome aberrations. Nanoparticles of cobalt chromium alloy caused DNA double strand breaks and chromosome aberrations, of which the majority were tetraploidy. Ceramic nanoparticles induced only single strand breaks and/or alkaline labile sites when indirectly exposed to human fibroblasts.

The assessment of reproductive risk from maternal exposure to biomaterials, especially those liberated by orthopaedic implants, is not yet possible with epidemiology. Whilst the barrier model used here differs from the in vivo situation in several respects, it may be useful as a framework to evaluate biomaterial induced damage across physiological barriers.