Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems. The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively.

This retrospective study included 2,294 uncemented primary THAs using the posterior approach performed by two attending surgeons from January 2016 to December 2022. Both surgeons switched from a collarless femoral stem design to a collared design in May 2020. Data was collected regarding stem design, frequency of PFF, and requirement for revision surgery. Periprosthetic fractures were identified and confirmed using medical records and/or radiographic imaging. Fracture rates and percentages between collared and collarless stems were then analyzed. A Fisher's Exact Test was performed to determine if there was a significant association between collared and collarless stem use on PFF rates.

A total of 2,294 uncemented primary THAs performed by 2 surgeons were eligible for analysis. 903 (39.4%) patients received a collared stem, and 1,391 (60.6%) patients received a collarless stem. In total, 14 (0.6%) PFFs occurred over the study period. There was 1 fracture (0.1%) out of 903 collared stems, and 13 fractures (0.9%) out of 1,391 collarless stems (p = 0.012).

Collared stems were associated with a significant decrease in PFF rate when compared to collarless stems in uncemented primary THA. Future studies are encouraged to continue to investigate PFF and other complication rates with the use of a collared stem design.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims

Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error.

Methods

A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Δsacral slope(SS)stand-sit > 30°), or stiff (SSstand-sit < 10°) spinopelvic mobility contributed to increased error rates.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 66 - 66
1 Oct 2018
Vigdorchik JM Novikov D Abdel MP Mercuri J Long WJ Bosco J Schwarzkopf R
Full Access

Introduction

Complications can be defined as preventable, potentially preventable, or non-preventable. While often discussed, there are virtually no data whether or not the most common causes of revision total hip arthroplasty (THA) are preventable or not. The goal of this study was to identify and report preventable causes of revision THA within 5 years of the index THA.

Methods

We conducted a retrospective review of 128 consecutive revision THAs between August 2015 and August 2017, with 62% being referred from another institution. Mean time to revision THA from the index arthroplasty was 10 months. Mean age at revision THA was 61 years, with 67% being female. Three fellowship-trained adult reconstruction surgeons reviewed the radiographs and operative notes and classified the revision THAs into two categories: preventable vs. non-preventable. Reviewers were instructed to be extremely lenient with the benefit of the doubt given to the operative surgeon. Inter-observer reliability was assessed by Cohen's kappa analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 33 - 33
1 Oct 2018
Iorio R Aggarwal V Stachel A Phillips M Schwarzkopf R Vigdorchik JM Bosco JA Long WJ
Full Access

Introduction

There has been a renewed interest in the surgical approach used for total hip arthroplasty (THA). Risk factors for periprosthetic joint infection (PJI) have been well studied over the past decade, yet PJI remains one of the most devastating complications following THA. We studied the impact of direct anterior (DA) versus non-direct anterior (NA) surgical approaches on PJI, and examined the impact of new perioperative protocols on PJI rates following all surgical approaches at a single institution.

Methods

6086 continuous patients undergoing primary THA at a single institution from 2013–2016 were retrospectively evaluated. Data obtained from electronic patient medical records included age, sex, body mass index (BMI), medical comorbidities, surgical approach, and presence of deep PJI. Deep PJI was defined according to National Healthcare Safety Network's (NHSN) criteria for joint space infection following prosthetic hip replacement. Infection rates were calculated yearly for the DA and NA approach groups. Covariates were assessed and used in multivariate analysis to calculate adjusted odds ratios for risk of development of PJI with DA compared to NA approaches. In order to determine the effect of adopting a set of infection prevention protocols and patient optimization on PJI, we calculated odds ratios for PJI comparing patients undergoing THA for two distinct time periods: 2013–2014 and 2015–2016. These periods corresponded to before and after we implemented a set of perioperative infection protocols.