header advert
Results 1 - 18 of 18
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 70 - 70
24 Nov 2023
Roskar S Mihalic R Trebse R
Full Access

Aim

Prosthetic joint infection (PJI) represents the second most frequent complication of total joint arthroplasty (TJA) with up to 20% of low-grade PJI treated as aseptic failure. Sensitive diagnostic criteria have been provided by EBJIS. However, to date there is no single test to reliably diagnose all PJIs. Studies of Mazzucco et al. and Fu et al. suggest that synovial fluid (SF) viscosity could be considered as an important marker for PJI. The primary aim of our study was to determine if SF viscosity is a more reliable diagnostic criterion of PJI than the SF cell count with differential (CCD), and the combined diagnostic value of SF viscosity and CCD.

Method

We prospectively analysed the viscosity of SF samples obtained during TJA of hip and knee revisions. We sampled 2.5–5mL of SF for viscosity and CCD. Intraoperatively, 1mL of the sample was analysed for the CCD. The remaining SF was centrifuged for 4min at 7000rpm. The viscosity of the supernatant was determined on Ostwald viscometer as the time required to pass the viscometer at 20°C. During each surgery at least 5 microbiological and multiple histopathological samples were harvested, and explant sonication was performed. The diagnosis was based on EBJIS definition. The viscosity threshold for detecting PJI was set at 65 seconds.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 7 - 7
24 Nov 2023
Martos MS Boadas L Trebse R Marais L Ruiz PS Vaznaisiene D Grenho A Ferrari MC Soriano A
Full Access

Aim

Two-stage replacement is a frequent procedure in patients with chronic PJI. However, results in the literature after this procedure differ, ranging from 54% to 100% of infection eradication. Positive cultures at reimplantation, when performing the second stage, are perceived as a risk factor for reinfection. This study aims to determine the impact of positive cultures during the second stage on the outcome of patients undergoing a 2-stage septic replacement and the impact of antibiotic holidays between the first and the second stage.

Method

We systematically searched four databases from inception to May 31, 2022. We combined terms related to PJI, joint replacement and culture results. We analysed the risk of failure when positive cultures at second stage and performed a subgroup analysis by antibiotic holiday period.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim

Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs.

Method

Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 69 - 69
1 Oct 2022
Roskar S Mihalic R Mihelic A Trebse R
Full Access

Aim

Debridement, antibiotics and implant retention (DAIR) are considered as an optimal curative treatment option for prosthetic joint infection (PJI) when the biofilm is still immature and radical debridement is achievable. There are two main groups of patients suitable for DAIR. Those with an early acute PJI and patients with acute hematogenous PJI. However, there is also a third group of early PJI resulting from a wound healing problem or leaking hematoma. These may be either high or low grade depending on the microorganisms that infected the artificial joint “per continuitatem”.

Methods

We retrospectively analysed 100 successive DAIR procedures on prosthetic hip and knee joints performed between January 2010 and January 2022, from total of 21000 primary arthroplasties implanted within the same time period. We only included PJI in primary total replacements with no previous surgeries on the affected joint. Patients data (demographics, biochemical, microbiological, histopathological results, and outcomes) were collected from hospital bone and joint infection registry. The aim of surgery was radical debridement and the mobile parts exchange. The standardized antibiotic regime based on antibiofilm antibiotics.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 32 - 32
1 Dec 2021
Mihalic R Zdovc J Brumat P Trebse R
Full Access

Aim

The cut-off values for synovial fluid leukocyte count and neutrophils differential (%PMN) for differentiating aseptic from septic failure in total knee arthroplasties were already defined in the past. Our goal was to determine the cut-off values for synovial fluid leukocyte count and %PMN in failed total hip arthroplasties (THA).

Method

Patients undergoing revision THA were prospectively included. In perioperative assessment phase, synovial fluid leukocyte count and %PMN were determined. During the surgery, at least 4 intraoperative samples for microbiological and one for histopathological analysis were obtained. Infection was defined as presence of sinus tract, inflammation in histopathological samples, and ≥2 tissue and/or synovial fluid samples growing the same microorganism. Exclusion criteria were systemic inflammatory diseases, revision surgery performed less than 3 months from index surgery and insufficient tissue sampling. Receiver operating characteristic (ROC) curves were constructed to assess the diagnostic performance and Youden's J statistic was computed to identify optimal cut-off values.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 36 - 36
1 Dec 2021
Roskar S Mihalic R Trebse R
Full Access

Aim

Prosthetic joint infection (PJI) presents the second most common complication of total joint arthroplasty (TJA). Accumulating evidence suggests that up to 20% of aseptic failures are low-grade PJI. However, there is still no single test to reliably diagnose all PJI. In his thesis, Mazzucco emphasized the viscosity differences between normal, osteoarthritic, and rheumatic synovial fluid. Similarly, a recent study by Fu et al. reported significantly lower viscosity in patients with PJI compared to the aseptic failure cohort. The primary aim of our study was to determine whether synovial fluid viscosity is a more reliable diagnostic criterion for PJI compared to the synovial fluid cell count with differential and serum C-reactive protein (CRP) levels.

Method

We prospectively analyzed the viscosity of synovial fluid samples obtained during TJA of hip and knee joint revision procedures. We sampled 2.5–5 mL of synovial fluid for viscosity measurement. The samples were centrifuged (4 min at 7000 rpm) and the resulting supernatant was immediately transferred into the Ostwald viscometer. Viscosity was derived from the time required for a given volume of synovial fluid to pass the viscometer at 20 °C. The synovial fluid samples were also analysed for their cell count with differential and serum CRP was measured. The definite diagnosis of PJI was established on basis of EBJIS criteria. For the viscosity, the threshold for detecting PJI was set at 65 seconds.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 6 - 6
1 Mar 2021
Mihalic R Zdovc J Brumat P Trebse R
Full Access

Aim

One of the most accurate and inexpensive tests in detection of prosthetic joint infection (PJI) is synovial fluid white blood cell (WBC) count and differential. Since leukocytes produce many different interleukins (IL) in situation of PJI, we hypothesized that ILs could be even more accurate in detection of PJI. The aim of the study was to test, if the synovial fluid IL-6 level is superior to WBC count and differential in detection of PJI.

Methods

Unselected patients undergoing total hip or knee revision surgery were prospectively included. In perioperative assessment phase, WBC count, differential and IL-6 levels of synovial fluid were measured. Patients were labelled as positive or negative according to the predefined cut-off values for IL-6 (230pg/ml) and WBC count with differential (1,7 × 109 WBC/ml with ≥65% of granulocytes). During the surgery, at least 4 intraoperative samples for microbiological and one for histopathological analysis were obtained. PJI was defined as presence of sinus tract, inflammation in histopathological samples, and growth of the same microorganism in at least two or more samples of periprosthetic tissue or synovial fluid. Binary diagnostic test was performed to check the diagnostic strength of both methods in detection of PJI.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 86 - 86
1 Dec 2019
Trebse R Kanalec T Angelini K Baljak S Filipič T Levašic V
Full Access

Aim

”There is not a lot of data of the frequency and impact of unwanted events including glove perforation, contamination of the surgical field (drape perforation, laceration, detachment, bone bounced back from an unsterile object), unsterile object in the surgical field (hair, sweat droplet…), defecation, elevated air temperature, and others. Mishaps occur in every surgical theatre. These events should influence the surgical site infection rate but it is not clear to what extent. We wanted to calculate the frequency and measure the impact of these events on the infection and revision rate of the relative patients.”

Method

”In our institution, scrub nurses prospectively record untoward events in the theatres. Surgeons register complications before discharge. Stratified failures are recorded since 2002 within a registry. We analysed the respective databases and compared the revision and infection rate in the group with untoward effects with the outcome of all arthroplasty patients within the same time period. Two tailed Z statistical test was used for analysis.”


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 1 - 1
1 Dec 2018
Wouthuyzen-Bakker M Sebillotte M Lomas J Kendrick B Palomares EB Murillo O Parvizi J Shohat N Reinoso JC Sánchez RE Fernandez-Sampedro M Senneville E Huotari K Allende JMB García AB Lora-Tamayo J Ferrari MC Vaznaisiene D Yusuf E Aboltins C Trebse R Salles MJ Benito N Vila A Del Toro MD Kramer T Petersdorf S Diaz-Brito V Tufan ZK Sanchez M Arvieux C Soriano A
Full Access

Aim

Late acute prosthetic joint infections (PJI) treated with surgical debridement and implant retention (DAIR) have a high failure rate. The aim of our study was to evaluate treatment outcome in late acute PJIs treated with DAIR versus implant removal.

Method

In a large multicenter study, late acute PJIs were retrospectively evaluated. Failure was defined as: PJI related death or the need for prosthesis removal or suppressive antibiotic therapy because of persistent or recurrent signs of infection. Late acute PJI was defined as < 3 weeks of symptoms more than 3 months after the index surgery.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 92 - 92
1 Dec 2018
Wouthuyzen-Bakker M Sebillotte M Lomas J Taylor A Palomares EB Murillo O Parvizi J Shohat N Reinoso JC Sánchez RE Fernandez-Sampedro M Senneville E Huotari K Allende JB Garcia-Cañete J Lora-Tamayo J Ferrari MC Vaznaisiene D Yusuf E Aboltins C Trebse R Salles M Benito N Vila A Del Toro MD Kramer T Petershof S Diaz-Brito V Tufan ZK Sanchez M Arvieux C Soriano A
Full Access

Aim

Debridement, antibiotics and implant retention (DAIR) is the recommended treatment for all acute prosthetic joint infections (PJI). However, the efficacy of DAIR and identification of risk factors for failure in patients with late acute PJI, is not well described.

Method

Patients diagnosed with late acute PJI between 2005 and 2015 were retrospectively evaluated. Late acute PJI was defined as the development of acute symptoms (≤ 3 weeks) occurring ≥ 3 months after arthroplasty. Failure was defined as: i) the need for implant removal, ii) infection related death, iii) the need for suppressive antibiotic therapy due to persistent signs of infection and/or iv) relapse or reinfection during follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 10 - 10
1 Dec 2018
Renz N Trebse R Akgün D Perka C Trampuz A
Full Access

Aim

Treatment of enterococcal periprosthetic joint infections (PJI) is challenging due to heterogeneous pathogenesis, non-standardized management strategies and lack of biofilm-active antibiotics. Previous studies report treatment success from 50–76%. We evaluated the characteristics and outcome of enterococcal PJI, in particular the influence of antimicrobial treatment regimens.

Method

Consecutive patients with enterococcal PJI treated at two specialized orthopaedic institutions were retrospectively included from 2010 to 2017. PJI was defined by the proposed European Bone and Joint Infection Society (EBJIS) criteria. Adequate antimicrobial treatment was considered when the antibiotic was appropiate for the treatment of enterococcal bone infections (activity, dose, oral bioavailability, bone penetration). The treatment success (defined as no relapse of enteroccal infection) and clinical success(i.e. infection-free status) was evaluated and compared using Fishers exact test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 11 - 11
1 Mar 2017
Mohar J Knez D Cirman R Trebse R Mihalic R Vrtovec T
Full Access

Summary

Optimum position of pedicle screws can be determined preoperatively by CT based planning. We conducted a comparative study in order to analyse manually determined pedicle screw plans and those that were obtained automatically by a computer software and found an agreement in plans between both methods, yet an increase in fastening strengths was observed for automatically obtained plans.

Hypothesys

Automatic planning of pedicle screw positions and sizing is not inferior to manual planning


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 45 - 45
1 May 2016
Mihalic R Trebse R
Full Access

Background

Total hip arthroplasty (THA) is one of the most successful surgical procedures ever performed. Nevertheless if procedure is performed by high or low volume surgeons; more than 50% of cups are still placed out of the safe zone, which is connected to lower survival rate of the prosthesis. The idea was to develop an imageless navigation system for safe and accurate positioning of the cup in THA procedures, without a need of any preoperative computer tomography (CT) or magnetic resonance imagining (MRI).

Methods

The validation of the system was approved by National Ethics Committee. The committee allowed the validation on 10 patients who all signed the agreement for participation in the study. Unselected patients undergoing THA were included. All patients had had performed preoperative x-rays of pelvis and hips for standard preoperative planning. Immediately before skin incision, anterior pelvic plane (APP) was defined with help of specially developed electromagnetic navigation system (Guiding Star, E-Hip module, Ekliptik d.o.o., Ljubljana, Slovenia) and specificaly designed hardware tool which is essential for accurate APP determination [Fig.1]. In all patients THAs were performed through direct lateral approach and all implanted components (Allofit S cup and Alloclassic stem, Zimmer Inc., Warsaw, Indiana, USA) were implanted with freehand technique according to preoperative plan. After placement of the cups their inclination and anteversion angles were determined with aforementioned navigation system [Fig. 2]. The day after surgery, low dose CT scans of pelvises of operated patients were performed and DICOM format files were up-loaded into EBS software (Ekliptik d.o.o., Ljubljana, Slovenia), a multipurpose application for perioperative planning, measuring and constructing where virtual copies of pelvises were generated. On virtual pelvises the position of the cups was measured by independent person [Fig.3]. Measurements were compared, statistically analysed and the deviation calculated with root mean square error (RMSE) method. Afterwards the average error (eaver) and standard deviation (σ) between intraoperatively determined and postoperatively measured angles were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 132 - 132
1 Sep 2012
Milosev I Kovac S Trebse R Levasic V Topolovec M Pisot V
Full Access

Introduction

Alternative bearings – metal-on-metal and ceramic-on-ceramic bearings have been introduced in the last decade with the aim to diminish wear and, subsequently, aseptic loosening and osteolysis. These bearings were aimed for younger, more active patients. Clinical results which would compare the performance of various alternative and traditional bearings are scarce.

Methods

Between January 2000 and December 2002, we performed 487 total hip replacements in 474 patients using three types of bearings: metal-on-metal (MOM), metal-on-polyethylene (MOP), and ceramic-on-ceramic (COC). All patients received the same type of acetabular cup (Bicon-Plus, Plus Orthopedics) and same type of femoral component (SL-Plus, Plus Orthopedics). We used the hospital computer database for the evaluation of patient data and data on revision operations.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 608 - 608
1 Oct 2010
Mihalic R Tercic D Trampuz A Trebse R
Full Access

Background: Preoperative aspiration of synovial fluid is not always possible. Intraoperative collection of synovial fluid for determination of cell count and differential may be a useful approach for diagnosing or excluding prosthetic joint infection (PJI). However, the value and accuracy of synovial fluid collected during surgery has not yet been prospectively investigated. We analysed intraoperatively collected synovial fluid cell count for rapid and accurate diagnosis of PJI.

Methods: Unselected patients undergoing total hip or knee revision surgery from 06/06-05/08 were prospectively included. During surgery, synovial fluid was collected for determination of cell count; the cut-off value for PJI was > 1700 leucocytes/mm3 and/or > 65% neutrophils (according to Am J Med2004;117:556). In addition, 6 intraoperative samples were obtained for microbiology and 1 for histopathology. PJI was defined as presence of intraoperative pus, acute inflammation in histopathology, or ≥2 tissue samples growing the same organism.

Results: 59 patients (median age, 69 years; 68% females) with hip (n = 41) and knee (n = 18) prostheses were included, of whom 20 (34%) had PJI. Synovial fluid cell counts were true-positive in 16, true–negative in 38, false–positive in 1 and false–negative 4 patients. Sensitivity of synovial fluid cell count was 80%, specificity 97%, positive and negative predictive values were 94% and 90%, respectively.

Conclusion: The intraoperative synovial fluid cell count analysis is a rapid, inexpensive and reliable test for predicting or excluding PJI, having a ≥90% positive and negative predictive value. This test may be used for making operative decisions during surgery.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 310 - 311
1 Mar 2004
Trebse R Milosev I Fonda S
Full Access

Introduction: Stress shielding has been found to cause cortical thinning and loss of trabecular bone in the proximal femur due to stiff steam and elastic bone. To avoid these problems a prosthesis was developed according to the concept of isoelasticity. Its aim was to ensure the implant and the bone to deform as one unit loading the bone in a more physiological way. Methods: From 1984 Ð1987 we performed 149 total hip replacements using third generation Mathys isoelastic polyacetal stem with stainless-steel heads and polyethylene cementless acetabular cups. Average patient age was 47 years (21–82). Eleven patients (12 hips) has died before revision and fourteen (15 hips) were lost to follow up. Results: Hitherto 69 hips were revised, þve due to infection. The 10 years revision rate for any reason was 68.7%. The remaining 48 patients (53 hips) have been clinically and radiologically assessed or reviewed by a questionnaire. In these patients the average HHS was 80 points. Thirteen among them had failed radiologically, many without a poor subjective result. Conclusions: The performance of this prosthesis was unacceptably poor but nevertheless the concept of isoelasticity should not be completely disregarded. Future trends may reconsider and reintroduce some new materials or implant designs which would be able to achieve the aim of isoelasticity without former problems. Long term total hip loosenings are still all but solved.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 303 - 303
1 Mar 2004
Trebse R Molicnik A
Full Access

Introduction: Femoral fracture after total or hemiar-throplasty is an uncommon but often difþcult complication to treat. Its incidence varies from 1% after primary THA to 4% after revision THA. The goal of our study was to determine the healing rate of the fractures and the clinical outcome of the patients analysed against type of fractures, method of þxation and loosening of the prostheses. Methods: We retrospectively analysed 63 operatively treated patients with periprosthetic femoral fractures operated on in two large institutions from the year 1994 with at least 12 month of follow-up. Fractures were classiþed according the Vancouver classiþcation system. Perioperative femoral fractures were excluded from the study. Results: According the Beals and Tower we had 38 excellent, 13 good and 7 poor results, one patient died in the early postoperative period and 4 were lost to follow-up. 16 procedures were associated with a perioperative complication. Conclusions: We think that fractures associated with a loose interface cemented or cementless are best treated by removal of the implant and insertion of a long stemmed prosthesis in the reduced femur. A periprosthetic fracture associated with a stable prosthesis can be safely treated by a reduction and internal þxation. The use of cement in revision is a good choise in the older patient who needs a fast mobilisation and early full weight bearing.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 326 - 326
1 Mar 2004
Trebse R Trampuz A Fonda S
Full Access

Introduction: Standard therapy for orthopedic device infections includes a two-stage exchange and prolonged antimicrobial therapy. In a subgroup of patients, retention of the device seems to be an effective alternative. Methods: In a prospective study we evaluated treatment efþcacy of orthopedic device infections with implant retention. Inclusion criteria were: early manifestation, stable implant, known pathogen, susceptibility of staphylococci to quinolones and rifampin, good condition of soft tissue. Initially, intravenous antimicrobial therapy was given for 2 weeks, followed by oral treatment for 10 weeks (knee prostheses for 6 months). Results: From January 1999 through June 2002, 19 patients were included: hip prosthesis (9), knee prostheses (6) and internal þxation devices (4). Isolated pathogens were: staphylococci (14), streptococci (4), enterococci (1), and Propionibacterium acnes (1). Open debridement with device retention was performed in 13 patients; the remaining 6 patients were treated with antibiotics only. After initial 2-week intravenous therapy, staphylococcal infections were treated with oral ciproßoxacin 750 mg bid + rifampin 450 mg bid, streptococcal and enterococcal infections with oral amoxicillin 750 mg tid and the P. acnes-infection with oral clindamycin 600 mg tid. 12 of 16 patients were followed for at least 24 months. 10 (83%) had no symptoms or signs of infection at follow-up, 2 (17%) had a relapse Conclusion: In carefully selected patients, device retention with antimicrobial treatment for 3–6 months may be an effective approach.