header advert
Results 1 - 20 of 66
Results per page:
Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims

The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs).

Methods

This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 19 - 19
1 Jun 2016
Stirling E Gikas P Aston W Miles J Pollock R Carrington R Skinner J Briggs T
Full Access

Introduction

THR is one of the most frequently performed operations nationally. A large number of prostheses are available, and the procedure is therefore associated with variation in practice and outcomes. NICE guidelines aim to standardise best practice, and are informed by separate, independent bodies, such as the NJR and ODEP, which monitor data about the implants used and their performance. This study aims to determine whether clinical practice and component use has changed since the publication of NJR data.

Methods

NJR reports from 2006–2014 were analysed, with record made of the different prostheses used in THR, noting ODEP ratings of components used. Analysis was also performed by component type (i.e. cemented and cementless stems and cups), and combinations of components, according to their frequency of use in a given year. The Kruksal-Wallis test was used for statistical analysis.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 57 - 57
1 Dec 2014
Olivier A Ghani Y Konan S Khan S Briggs TWR Skinner J Pollock R Aston W
Full Access

Introduction:

Non-invasive extendible endoprostheses (NIEE) were primarily developed for salvage after musculo-skeletal tumour surgery in the immature skeleton. However, they may also have a unique application to manage complex limb reconstruction in revision surgery to address limb-length inequality in the mature skeleton. The aim of this study is to present the minimum 2 –year results of using non-invasive extendible endoprostheses for complex lower limb reconstruction.

Methods:

Between 2004 and 2013, 21 patients were treated with 23 NIEE. The indication for surgery was salvage of infected prosthesis following primary tumor resection in 6 cases, aseptic prosthesis failure after primary tumour resection in 5 cases, aseptic non-tumor prosthesis failure in 1 case, infected non-tumor prosthesis in 8 cases and symptomatic non-union of graft reconstruction in 3 cases. There were 14 male and 7 female patients with a mean age of 49.8 years (range 19–81).


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 18 - 18
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Pigmented Villonodular Synovitis (PVNS) is a rare inflammatory disorder of the synovium, bursa and tendon sheath. The objective of this study was to evaluate the long-term outcomes and morbidity associated with operative management of PVNS of the hand.

Methods:

Histological databases were retrospectively interrogated. All patients between 2003–2008 with confirmed PVNS of the hand were included in the study.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 29 - 29
1 Dec 2014
Olivier A Briggs T Khan S Johnston L Faimali M Gikas P Jagiello J Skinner J Aston W Pollock R
Full Access

Introduction:

Endoprosthetic replacement of the proximal femur is common in the management of bone tumours and failed revision arthroplasty. This study seeks to compare those patients undergoing acetabular resurfacing at the time of femoral replacement with those patients where the native acetabulum was preserved.

Methods:

All proximal femoral replacements from 2004 to 2009 with a five year follow up were included. Case files were interrogated to identify those that had either revision surgery or dislocation of the hip.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 58 - 58
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Distal femoral replacement is recognised as the optimum treatment for malignant distal femoral tumours. Aseptic loosening is known to be a major cause for failure in these implants. Studies have indicated that the HA coated collar promotes osteointegration and bony in growth. This study compares long term aseptic loosening in implants with HA coated collars to those without in the immature skeleton.

Objectives:

To assess the effect of HA coated collars on aseptic loosening in extendable distal femoral replacement prosthesis in the immature skeleton.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 24 - 24
1 Apr 2013
Jalgaonkar A Mohan A Dawson-Bowling S Muthukumar T Pollock R Skinner J Cannon S Briggs T Aston W
Full Access

Introduction

Local recurrence of tumours along the biopsy tract is a known complication of percutaneous closed needle biopsy. Correct surgical management requires preoperative identification and excision of the biopsy tract at time of surgery. These tracts become increasingly difficult to identify with time, leading to risk of inadequate excision of the biopsy tract and recurrence of the tumour at the biopsy site.

Materials/Methods

In a prospective study conducted at our institution, 22 of the 45 patients with musculoskeletal tumours (49%) had unidentifiable biopsy sites, with a mean duration between biopsy and definite surgery being 98 days (range 13–164 days). We concluded that identification of the biopsy site was more difficult after 50 days. Radiotherapy related scar formation and the longer time duration between biopsy and definite surgery in patients requiring neoadjuvant therapy made identification more unlikely. Consequently, all patients received India ink skin tattoo to mark the biopsy site at the time of the needle biopsy. 56 patients were then prospectively reviewed on the day of surgery to identify the biopsy site.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 7 - 7
1 Feb 2013
Sewell M Carrington R Pollock R Skinner J Cannon S Briggs T
Full Access

Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population.

Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 115 - 115
1 Sep 2012
Gillott E Kahane S Aston W Briggs T Skinner J Pollock R
Full Access

Aims

Present the outcomes of those patients diagnosed with Ewing's Sarcoma of the foot within the past 10 years and treated at the Royal National Orthopaedic Hospital's Bone Tumour Unit, Stanmore.

Methods

Retrospective study of the cases identified from the pathology database. Notes reviewed for presentation, treatment and follow up. TESS (Toronto Extremity Salvage Score) and MSTS (Musculoskeletal tumour score) were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 85 - 85
1 Sep 2012
Stammers J Kahane S Malek S Aston W Miles J Pollock R Carrington R Briggs T Skinner J
Full Access

Infection after knee arthroplasty is a devastating complication. Our aim is to present our outcomes of treating infected knee replacements at a tertiary referral centre.

We performed a consecutive, retrospective case series of all revision knee arthroplasty for infection between January 2006 and December 2008. Case notes were reviewed and data collated on the date and institution of primary arthroplasty, procedures undertaken at our institution, microbiology and bone loss post first stage, serological markers (C-reactive protein, ESR) prior to second stage and outcome.

During this three year period we performed 430 knee revision operations. 51 were in the presence of deep chronic infection. 90% were referred from other hospitals. Overall infection was successfully eradicated in 69%.

Nineteen patients underwent repeat two-stage and overall eleven (58%) patients had successful eradication of infection with multiple two-stages. Of these 47% had F3/T3, the highest grading of Anderson Orthopaedic Research Institute bone loss indicating no metaphyseal bone. A further 12% had bicondylar deficiency on the tibia and no femoral metaphyseal bone (F3/T2b).

Multidrug resistance present in 69% and 47% were infected with multiple organisms. All members of the unsuccessful outcome group had at least one multidrug resistant organism compared to 43% in the successful cohort (P=0.0002). Multiple organisms are associated with an unsuccessful outcome (P=0.056).

Serological markers were not significantly different between the successful and unsuccessful outcome groups.

Where the referring hospital had attempted revision and failed, the chance of eradicating infection dropped from 75% to 58% and the rate of above knee amputation was twelve times higher (3% vs. 36%).

Custom constrained, rotating hinge prostheses enable aggressive soft tissue debridement including ligaments. Successful two-stage requires a multidisciplinary approach including tissue viability nurses, microbiologists and plastic surgeons. Where units lack revision expertise this series suggests early referral increases the chance of limb salvage.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 110 - 110
1 Sep 2012
Perera J Griffiths D Gikas P Perera J Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis, for tumour, between 1997 and 2007. The mean age was 46 years, (7–87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3% and the mean TESS was 77.2%.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7% and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 321 - 321
1 Sep 2012
Jalgaonkar A Mohan A Pollock R Skinner J Cannon S Briggs T Aston W
Full Access

Percutaneous biopsies can lead to seeding of tumour cells along the biopsy tract.

Correct surgical management requires preoperative identification and excision of the biopsy tract at time of surgery. These tracts become increasingly difficult to identify with time, leading to risk of inadequate excision of the biopsy tract and recurrence of the tumour at the biopsy site. We conducted a prospective study involving 45 patients who had tissue biopsies for bone and soft tissue tumours between February and May 2008. All the biopsies were performed by consultant radiologist under ultrasound or CT guidance. Case note analysis, patient history and examination at the time of surgery were used to collect data. 23 of 45 patients had accurate identification of the biopsy tract by the surgeon at the time of excision. The mean time between biopsy and excision was 52 days (range 6–140). 22 of 45 patients had unidentifiable biopsy site, with the mean time between biopsy and excision being 98 days(range 13–164) p=0.0004(paired t test). All 4 patients who received post-biopsy radiotherapy had unidentifiable biopsy site tract (mean duration 104 days) and 11 of the 18 patients who underwent neoadjuvant chemotherapy had an unidentifiable biopsy tract (mean duration 108 days). We concluded that identification of biopsy site was more difficult after 50 days, especially in patients who underwent radiotherapy and chemotherapy.

Following this study, all the patients who had biopsies of tumours had the site marked with India ink tattoo. We, then prospectively reviewed 36 patients between July and September 2010 who underwent excision of bone and soft tissue tumours and had their biopsy sites marked with India ink tattoo. After needle biopsy, one drop of the dye was applied at the site of the biopsy. This was taken up by capillary action beneath the dermis and remained present until the patient returned for their definitive surgery. The biopsy site was easily identifiable by the patients and the operating surgeon in all 36 patients. The mean time between biopsy and surgery was 77 days (range 10–299 days). Tattooing of the skin enabled the surgeon to accurately excise the biopsy tract along with the tumour. We recommend this technique of tattooing of the biopsy site with India ink, as it is safe, easily recognisable and permits accurate excision of the tract (including the tattoo), therefore preventing biopsy tract recurrence.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 116 - 116
1 Sep 2012
Dawson-Bowling S Berber O Jalgaonkar A Miles J Aston W Pollock R Skinner J Briggs T
Full Access

Bizarre parosteal osteochondromatous proliferation (BPOP), or Nora's lesion, is a rare condition characterised by the formation of surface-based osteocartilaginous lesions typically affecting the hands and feet. 22 cases were identified from the records of a regional bone tumour unit, dating from 1985 to 2009. Of 22 cases, 9 lesions involved the long bones of the hand, 7 the long bones of the feet, 1 case originated from a sesamoid bone of the foot and 5 from long bones (radius, ulna, femur [2] and tibia). Age ranged from 6 to 66 (mean: 31.8) and male to female ratio was 1.8:1. Diagnosis was based on combined radiological and histological features, and initial surgical treatment was excision in 21 cases, and 1 amputation. Follow-up ranged from 12–162 months (mean 32). Recurrence occurred in 6 patients (27%), with mean time to recurrence 49 months (range 10–120). 2 of 8 patients with complete resection margins developed recurrence (25%), versus 4 of 14 with marginal or incomplete resection (28%). Given the potential surgical morbidity inherent in resection, our data suggest that there may be a role for a relatively tissue-conserving approach to the excision of these lesions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 110 - 110
1 Sep 2012
Al-Hadithy N Gikas P Perera J Aston W Pollock R Skinner J Lotzof K Cannon S Briggs T
Full Access

The surgical treatment of bone tumours can result in large perioperative blood loss due to their large sizes and hypervascularity. Preoperative embolisation has been successfully used to downgrade vascularity, thus reducing perioperative blood loss and its associated complications. Prior to embolization era, blood loss as high as 18,500mL have been reported peri-opratively.

Twenty-six patients with a variety of bone tumours (average size 10.5×7.5×5.5cm), who underwent pre-operative embolisation between 2005 and 2009, were retrospectively studied. The group comprised of 17 females and 9 males. Their mean age was 38 years old. All patients underwent surgical resection within 48 hours of embolization. Mean blood loss was 796mL and required on average 1.1units of blood. We experienced no complications.

Pre-operative arterial embolisation of large, richly vascular bone tumours in anatomically difficult positions, is a safe and effective method of downstaging vascularity and reducing blood loss.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 5 - 5
1 Aug 2012
Dhinsa B Perera J Gallagher K Spiegelberg B Hanna S Tai S Pollock R Carrington R Cannon S Briggs T
Full Access

The aim of this study is to investigate whether MoM implants result in more chromosome aberrations and increased blood metal ions postoperatively whe compared to MoP implants.

MoM arthroplasties are being inserted in increasing numbers of younger patients due to the increased durability and reduced requirements for revision in these implants. Recent studies have raised many concerns over possible genotoxicity of MoM implants.

This is a prospective study of patients who have undergone elective total hip replacement, they were selected and then randomised into two groups. Group A received a MoP implant and group B received a MoM implant. Patients are reviewed pre-operatively (control group), at 3 months, 6 months, 1 year and 2 years post-operatively. On each occasion blood tests are taken to quantify metal ion levels (chromium, cobalt, titanium, nickel and vanadium) using HR-ICPMS method and chromosome aberrations in T lymphocytes using 24 colour fluorescent in situ hydridisation (FISH).

51 patients have been recruited to date, 23 of whom had MoP prosthesis and 28 a MoM. 47 of these had their 1 year follow-up with blood analysis and 38 have had 2 year follow up. There appeared to be a bedding period for both MoM and MoP groups, with an increase in metal ion release. The blood concentration of chromium, cobalt and titanium rise significantly in the MoM group at the 2 year stage. Chromosome aberrations occurred in both groups. Both the MoM and MoP groups showed increase frequency of aneuploidy aberrations and structural damage. The greatest increase in metal ion levels occurred at the 1 to 2 year interval corresponding to significant rise in chromosome aberrations.

Preliminary results of this study show that the levels of chromium, cobalt and titanium are significantly higher in the MoM group compared to the MoP group. This corresponds to increases in chromosome aberrations in the groups with increases in structural chromosome damage after two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 17 - 17
1 Jul 2012
Picardo N Blunn G Shekkeris A Aston W Pollock R Meswania J Cannon S Skinner J Briggs T
Full Access

Introduction

Following bone tumour resection, lower limb reconstruction results in leg-length discrepancy in skeletally immature patients. Previously, minimally invasive endoprostheses have been associated with a high risk of complications including joint stiffness, nerve injury, aseptic loosening and infection. The purpose of this study was to examine the outcome of the Stanmore non-invasive extendible endoprostheses used in our institution between 2002 and 2009 and compare them with implants used in the past.

Methods

Fifty-five children with a mean age of 11.4 years (5 to 16) underwent limb reconstruction with thirty-three distal femoral, two total femoral, eight proximal femoral and twelve proximal tibial implants. Forty-six endoprostheses were lengthened in clinic without anaesthesia using the principle of electromagnetic induction. Patients were assessed using the Musculoskeletal Tumour Society Score (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 40 - 40
1 Jul 2012
Sabharwal S Datta G Berber O Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Introduction

The proximity of the superior tibiofibular articulation to neurovascular structures makes the management of extraosseous tumours of the proximal fibula challenging in bone tumour surgery. The aim of study is to establish whether the recurrence rates are higher in this anatomical area compared to data that already exists in publication for bone tumours throughout the appendicular skeleton.

Method

A retrospective study of all patients treated for Ewing's tumours and osteosarcoma at a regional bone tumour unit between January 1995 and December 2009 was conducted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 16 - 16
1 Jul 2012
Perera J Gikas P Griffiths D Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 6 - 6
1 Jul 2012
Shekkeris A Pollock R Aston W Cannon S Blunn G Skinner J Briggs T
Full Access

Introduction

Primary bone tumours of the distal radius are rare, while it remains the third commonest site for primary lesions and recurrences of Giant Cell Tumours (GCT). The functional demands on the hand make reconstruction of the wrist joint following the excision of distal radius, particularly challenging.

Methods

A single-centre retrospective study, reporting the functional and oncological outcomes of six patients (4 males, 2 females - mean age of 53 (22 to 79)) who underwent a custom-made endoprosthetic replacement of the distal radius with arthrodesis at our institution, during 1999 - 2010. Five patients were diagnosed with primary bone sarcoma of the distal radius (4 GCTs, 1 osteosarcoma) and another had a metastatic lesion from a primary renal cell carcinoma. The diagnosis was confirmed by needle biopsy in all cases.

We assessed the patients' functional outcomes using the Musculoskeletal Tumour Society scoring system (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 76 - 76
1 Jun 2012
Gokaraju K Miles J Blunn G Unwin P Pollock R Skinner J Tillman R Jeys L Abudi A Briggs T
Full Access

Non-invasive expandable prostheses for limb salvage tumour surgery were first used in 2002. These implants allow ongoing lengthening of the operated limb to maintain limb-length equality and function while avoiding unnecessary repeat surgeries and the phenomenon of anniversary operations.

A large series of skeletally immature patients have been treated with these implants at the two leading orthopaedic oncology centres in England (Royal National Orthopaedic Hospital, Stanmore, and Royal Orthopaedic Hospital, Birmingham).

An up to date review of these patients has been made, documenting the relevant diagnoses, sites of tumour and types of implant used. 87 patients were assessed, with an age range of 5 to 17 years and follow up range of up to 88 months.

Primary diagnosis was osteosarcoma, followed by Ewing's sarcoma. We implanted distal femoral, proximal femoral, total femoral and proximal tibial prostheses. All implants involving the knee joint used a rotating hinge knee. 6 implants reached maximum length and were revised. 8 implants had issues with lengthening but only 4 of these were identified as being due to failure of the lengthening mechanism and were revised successfully. Deep infection was limited to 5% of patients.

Overall satisfaction was high with the patients avoiding operative lengthening and tolerating the non-invasive lengthenings well. Combined with satisfactory survivorship and functional outcome, we commend its use in the immature population of long bone tumour cases.