header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 38 - 38
1 Dec 2022
Sheridan G Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne J Kenny P Kurmis A Masri B Garbuz D Hurson C
Full Access

Hip resurfacing may be a useful surgical procedure when patient selection is correct and only implants with superior performance are used. In order to establish a body of evidence in relation to hip resurfacing, pseudotumour formation and its genetic predisposition, we performed a case-control study investigating the role of HLA genotype in the development of pseudotumour around MoM hip resurfacings.

All metal-on-metal (MoM) hip resurfacings performed in the history of the institution were assessed. A total of 392 hip resurfacings were performed by 12 surgeons between February 1st 2005 and October 31st 2007. In all cases, pseudotumour was confirmed in the preoperative setting on Metal Artefact Reduction Sequencing (MARS) MRI. Controls were matched by implant (ASR or BHR) and absence of pseudotumour was confirmed on MRI. Blood samples from all cases and controls underwent genetic analysis using Next Generation Sequencing (NGS) assessing for the following alleles of 11 HLA loci (A, B, C, DRB1, DRB3/4/5, DQA1, DQB1, DPB1, DPA1). Statistical significance was determined using a Fisher's exact test or Chi-Squared test given the small sample size to quantify the clinical association between HLA genotype and the need for revision surgery due to pseudotumour.

Both groups were matched for implant type (55% ASR, 45% BHR in both the case and control groups). According to the ALVAL histological classification described by Kurmis et al., the majority of cases (63%, n=10) were found to have group 2 histological findings. Four cases (25%) had group 3 histological findings and 2 (12%) patients had group 4 findings. Of the 11 HLA loci analysed, 2 were significantly associated with a higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) and 4 were noted to be protective against pseudotumour formation (DQA1*03:01:01, DRB1*04:04:01, C*01:02:01, B*27:05:02).

These findings further develop the knowledge base around specific HLA genotypes and their role in the development of pseudotumour formation in MoM hip resurfacing. Specifically, the two alleles at higher risk of pseudotumour formation (DQB1*05:03:01 and DRB1*14:54:01) in MoM hip resurfacing should be noted, particularly as patient-specific genotype-dependent surgical treatments continue to develop in the future.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 5 - 5
1 Feb 2021
Burson-Thomas C Browne M Dickinson A Phillips A Metcalf C
Full Access

Introduction

An understanding of anatomic variability can help guide the surgeon on intervention strategies. Well-functioning thumb metacarpophalangeal joints (MCPJ) are essential for carrying out typical daily activities. However, current options for arthroplasty are limited. This is further hindered by the lack of a precise understanding of the geometric variation present in the population. In this paper, we offer new insight into the major modes of geometric variation in the thumb MCP using Statistical Shape Modelling.

Methods

Ten participants free from hand or wrist disease or injury were recruited for CT imaging (Ethics Ref:14/LO/1059)1. Participants were sex matched with mean age 31yrs (range 27–37yrs). Metacarpal (MC1) and proximal phalanx (PP1) bone surfaces were identified in the CT volumes using a greyscale threshold, and meshed. The ten MC1 and ten PP1 segmented bones were aligned by estimating their principal axes using Principal Component Analysis (PCA), and registration was performed to enable statistical comparison of the position of each mesh vertex. PCA was then used again, to reduce the dimensionality of the data by identifying the main ‘modes’ of independent size and shape variation (principal components, PCs) present in the population. Once the PCs were identified, the variation described by each PC was explored by inspecting the shape change at two standard deviations either side of the mean bone shape.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 84 - 84
1 Apr 2018
Michna V Phillips A Hayes K Tulkis P Raja L Abitante P
Full Access

Introduction

Long term acetabular component fixation is dependent on bone ingrowth, which is affected by initial stability and the contact area between the bone and acetabular component. Mismatch between the component and cavity size has been shown to be one reason for component loosening. Furthermore, the potential of acetabular fracture during insertion of oversized components is larger than line-to-line components. An ideal cavity preparation would be a true hemispherical cavity that can provide maximum contact area between the shell and bone while also achieving adequate press fit for implant initial stability. The goal of this study was to characterize the cavity morphology produced by a commercially available reamer and compare it to a new reamer design.

Materials & Methods

36mm and 52mm reamers (n=6) were selected from conventional reamers (Stryker, Mahwah, NJ), which have successful clinical history exceeding 20 years, and Smooth Cut Reamers (Tecomet, Warsaw, IN and Stryker, Mahwah, NJ), which are a new design. Hemispherical cavities were created in 30 pcf polyurethane foam blocks (Pacific Research Laboratories, WA) using a custom software for the Mako System (Stryker, Mahwah, NJ), with new reamers of both designs. A reamer 2mm smaller in diameter than the final size was used to create a pilot cavity to replicate a clinically relevant reaming scenario.

The resulting cavities were scanned using a Triple Scan high resolution 3D Scanner (ATOS, Purchase, NY) to generate 3D models of each cavity. The models were then post processed, and the following dimensions were collected:

Gaussian best fit spherical diameter of the entire cavity (Dimension A)

Gaussian best fit diameter at the rim of the cavity (measured at a distance of 0.25mm from the top surface of the foam block) (Dimension B)

One-sided two sample T-tests were conducted to determine statistical significance.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 5 - 5
1 Feb 2013
Phillips A Goubran A Searle D Naim S Mandalia V Toms A
Full Access

We sought to validate a method of measuring the range of motion of knees on radiographs as part of a new system of “Virtual Knee Clinics”.

The range of motion of 52 knees in 45 patients were first obtained clinically with goniometers and compared to radiographs of these patients' knees in full active flexion and extension. Four methods of plotting the range of motion on the radiographs were compared.

The intra-class correlation coefficient (ICC) for inter-rater reliability using the goniometer was very high; ICC=0.90 in extension and 0.85 in flexion. The best ICC for radiographic measurement in extension was 0.86 indicating substantial agreement and best ICC in flexion was 0.95 (method 4). ICC for intra-rater reliability was 0.98 for extension and 0.99 for flexion on radiographic measurements.

Measuring range of motion of the knee has never previously been validated in the literature. This study has allowed us to set up a “Virtual Knee Clinic,” combining postal questionnaires and radiographic measurements as a surrogate for knee function. We aim to maintain high quality patient surveillance following knee arthroplasty, reduce our new to follow-up ratios in line with Department of Health guidelines and improve patient satisfaction through reduced travel to hospital outpatients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 1 - 1
1 Sep 2012
Phillips A Bartlett G Norton M Fern D
Full Access

The purpose of this study was to investigate whether patients who had had excision of the Ligamentum Teres as part of a surgical hip dislocation for femoro-acetabular impingement exhibited symptoms of acute Ligamentum Teres rupture post-operatively. Recent reports in the literature suggest that injury to the Ligamentum Teres can cause instability, severe pain and inability to walk.

We present the results of a postal questionnaire to 217 patients who had undergone open surgical hip dislocation for femoro-acetabular impingement where the LT was excised. This included seven patients who had undergone bilateral surgery. The questionnaire was designed to enquire about specific symptoms attributed to LT injuries in the literature; gross instability, incomplete reduction, inability to bear weight and mechanical symptoms.

161 patients responded (75%), with a total of 168 (75%) questionnaires regarding 224 hips completed. There were 104 females and 64 males. Median age was 34 and median follow-up was 52 months. All patients were found to have cam deformities, 72% (n=121) had associated labral tears. All patients were able to fully weight bear after surgery. 77% experienced no groin pain and 61% experienced no pain on exercise. 35% of patients experienced popping and locking in their operated hip and 24% had subjective feeling of their hip giving way. Oxford Hip scores and Nonarthritic Hip scores improved by 12 and 28 points respectively (n=47).

Our results show that the symptoms of pain and instability described with LT pathology can be present but are by no means universal. This leads us to conclude that their symptoms may be attributed to labral pathology which is frequently noted to coexist.