Ahmed N Norris R Bindumadhavan S Sharma A
Full Access

Abstract

Background

We know that tears of the Triangular fibrocartilage complex (TFCC) can cause DRUJ instability and ulnar sided wrist pain. This study shows the clinical result of patients who had arthroscopic transosseous repair of the TFCC tear with DRUJ instability. Arthroscopic repair of TFCC tear is a promising, minimally invasive surgical technique especially in patients with DRUJ instability.

Materials and methods

Fifteen patients who underwent TFCC one tunnel repair form 2018–2021 were reviewed retrospectively in hospital. The proximal component of TFCC was repaired through arthroscopic one- tunnel transosseous suture technique. VAS score for pain, wrist range of motion, grip strength and post operative complications were evaluated and each patient was rated according to the DASH score.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 13 - 13
1 Sep 2012
Jagodzinski N Singh T Norris R Jones J Power D
Full Access

We present the results of a bi-centre, retrospective study examining the clinical, functional and radiological outcomes of distal radius fracture fixation with the Aptus locking plates and Tri-Lock® variable angle locking screws. We assessed 61 patients with distal radius fractures with a minimum of six months follow-up. Functional assessment was made using the DASH score. We measured wrist range of movement and grip strength, and reviewed radiographs to assess restoration of anatomy, fracture union and complications. All fractures united within six weeks. Mean ranges of movement and grip strength were only mildly restricted compared to the normal wrist. The mean DASH score was 18.2. Seven patients had screws misplaced outside the distal radius although 3 of these remained asymptomatic. Five other patients developed minor complications. Variable angle locking systems benefit from flexibility of implant positioning and may allow enhanced inter-fragmentary reduction for accurate fixation of intra-articular fractures. However, variable-angle systems may lead to increased rates of screw misplacement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 30 - 30
1 Jul 2012
Spurrier E Wordsworth D Norris R Martin S Parker M
Full Access

Hip fractures are common injuries in the elderly, with significant mortality and morbidity from several factors. Many of these patients have cardiac disease, and some develop cardiac complications which may increase mortality.

Troponin T is a marker of myocardial injury but can be raised in other conditions. Patients over 60 years old admitted with hip fracture during the study period had their troponin T measured on admission and following surgery. Assay was performed after the patient had completed their treatment. We report the results of this study one year after the last patient was admitted.

108 patients were recruited. The average age was 84 years; 86% were female. This study found that 27% of hip fracture patients had some increase in the troponin T levels in the peri-operative period. This increase was not associated with an increase in early mortality, but there was an increase in one-year mortality for those with an increase in troponin T (45% versus 22%, p=0.03). These findings indicate that the routine measurement of troponin T after a hip fracture is unnecessary.