header advert
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 201 - 201
1 Dec 2013
Watanabe H Hachiya Y Murata H Muramatsu K Taniguchi S Kondo M Tanaka K
Full Access

Introduction

Higher concentrations of metal ion levels after Metal-on-metal (MoM) THA are a cause for concern. Elevated cobalt (Co) and chromium (Cr) ion levels in the blood indicate metal wear, and may predict secondary soft-tissue damage (adverse reaction to metal debris; ARMD). Although, it is well known that concentrations of metal ion levels are elevated in the short term after MoM, the long-term consequences in ion concentration and risk factors for increased ion levels are not clarified. We sequentially investigated the postoperative Co and Cr ion levels after MoM THA and the relationship between the metal ion levels and several risk factors.

Materials and Methods

We reviewed the data on one hundred and eighty six patients of two hundred ninety one MoM THA cases. The one hundred eighty six patients were measured at least three times after a MoM THA surgery over a five year (2005–2010) period in our institution. Serum cobalt and chromium levels were measured by inductor coupled plasma – mass spectrometry at several times in follow-up period, (measured at the preoperative period, the third month, the sixth month, the first year, the second year, and the fourth year after MoM THA). Furthermore, we investigated the correlation between the metal ion levels and various factors which might influence the release of metal ions, such as Body mass index (BMI), renal function, femoral head size, unilateral or bilateral THA, the cup position, and postoperative activity. The renal function was evaluated by measuring estimated glomerular filtration ratio (GFR) at preoperative examination. A postoperative activity was assessed with a pedometer measurement counting number of steps a day. A cup position was evaluated by lateral inclination measured by X-ray or computed tomography.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 197 - 197
1 Mar 2013
Hirakawa M Kondo M Tomari K Higuma Y Ikeda S Noguchi T Tsumura H
Full Access

Introduction

In total knee arthroplasty, patients sometimes have pain in the posterolateral part of the knee. One possible cause is the impingement of the popliteus tendon against femoral components. In the literature, the incidence has been reported to be 1–4%. The purpose of this study is to quantify the amount of posterolateral overhang of the femoral component using 3-D templating software.

Methods

We investigated 40 knees with varus osteoarthritic knees (Male 6 knees and Female 34 knees), all cases were grade 2 or lower in Kellgren Lawrence classification. Three-dimensional preoperative planning software was used to simulate the replacement of femoral component. The distal femur was simulated to cut 9 mm thickness on the lowest point of the medial condyles with 6 degrees valgus. The femoral mediolateral axis was simulated to be parallel to the surgical epicondylar axis. The size of femoral components was decided by anteroposteriol dimension of distal femur. Mediolateral location of the femoral component was that the lateral edge of the femoral components is just on the lateral cortex of the femur. In coronal plane, amount of M-L overhang of the femoral component was measured in 3 Zones (distal, proximal, center) on the surface of the posterior condyle cut (Figure 1).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 93 - 93
1 Jun 2012
Hirakawa M Kondo M Tomari K Sato M Itokawa T Kaku N Ikeda S Hara K Tsumura H
Full Access

Restoration of joint line in total knee arthroplasty (TKA) is important for kinematics of knee and ligamentous balance. Especially in revision TKA, it may be difficult to identify the joint line. The aim of this study is to define the relationship between epicondyles and articular surface using CT based three-dimensional digital templating sofware $“Athena” (Soft Cube, Osaka, Japan).

137 knees with osteoarthritis, all caces were grade 2 or lower in Kellgren-Lawrence index, were investigated. Perpendicular lines were dropped from the prominences of the medial and lateral femoral epicondyles to the most distal points of articular surfaces and distances of the lines were measured on the axial and coronal planes. The femoral width was measured as the distance between medial and lateral epicondyles. Each of the distance described above was converted to a ratio by dividing by the femoral width.

On the axial plane, the average distance from epicondyles to the posterior articular surfaces were 29.4±2.2mm on the medial side and 21.2±2.3mm on the lateral side. The average of the femoral width was 75.2±4.1mm. On coronal plane, the average distance from epicondyles to the distal articular surfaces were 25.2±2.8mm on the medial side and 21.4±2.5mm on the lateral side.

The ratio for the distance from epicondyles to the distal and posterior joint line compared to femoral width was 0.39±0.02, 0.28±0.03, 0.33±0.03 and 0.28±0.03. The distance from epicondyles to the distal and posterior joint line correlates with the femoral width of the distal femur. This information can be useful in determining appropriate joint line.