header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 19 - 19
2 May 2024
Shaarani S Moriarty P Vles G Haddad F Konan S
Full Access

We had previously reported on early outcomes on a new fluted, titanium, monobloc stem with a three degree taper that has been designed for challenging femoral reconstruction in the setting of extensive bone loss. The aim of this study was to report its mid-term clinical and radiographic outcomes.

This is a retrospective review of prospectively collected data carried out at a single institution between Jan 2017 and Dec 2019. 85 femoral revisions were performed using a new tapered, fluted, titanium, monobloc (TFTM) revision stem. Complications, clinical and radiographic data were obtained from medical records and a locally maintained database. Clinical outcomes were assessed using the Oxford Hip Score (OHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). All post-operative radiographs were analysed for subsidence, osteolysis and femoral cortical bone remodelling.

Mean follow-up was 60 months (range 28–84 months). Subsidence of 1.2 mm was noted in one patient. No cases of clinically significant subsidence (10 mm) were observed. At final follow-up, a statistically significant improvement was noted in functional outcome scores. The mean OHS preoperatively and at final follow-up were 24 (SD 13) and 42 (SD15). p = 0.04 mean difference 18 (95% CI 15–22). The mean WOMAC scores preoperatively and at final follow-up were 62 (SD23) and 88 (SD7) respectively (p < 0.001, mean difference 26; 95% CI 21–34). No stem fractures were noted within the follow-up period. Two patients had revision of the stem's one for infection and another for persistent pain.

Positive mid-term clinical and radiological outcomes have been observed with this tapered, fluted, titanium, monobloc stem. Based on these results, this implant may be considered as a viable option in the majority of uncemented femoral revisions.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 18 - 18
2 May 2024
Shaarani S Mohammad O Mohammad A Konan S
Full Access

The number of revision total hip arthroplasties (THA) is increasing. This procedure is associated with a higher complication rate than primary THA, and so it is important for patients to have realistic expectations. The aim of this systematic review was to gather and summarise the available evidence on patients’ expectations following revision THA.

A literature search was conducted in PubMed, PsycINFO, Cochrane, Google Scholar and Web of Science from inception to December 2021. Methodological quality was assessed by two independent reviewers using the National Heart, Lung and Blood Institute (NIH) study quality assessment tool for observational cohort and cross-sectional studies.

The search strategy generated 3132 references of which 4 articles met the inclusion criteria. Methodological quality scores ranged from 7–10. Patients have high expectations concerning future walking ability, pain and implant longevity. Implant longevity expectations vary according to the longevity of the primary implant. A significant positive correlation was found between fulfilled expectations of pain and walking ability and patient satisfaction (r = .46 – .47). Only one study assessed fulfilment of patient expectations. Great variability was seen in operationalisation and assessment of expectations.

Patients undergoing revision THA appear to have high expectations with regards to future outcomes. Whilst results are promising, there is a paucity of high-quality data in this area. Further research is needed, which places emphasis on developing a sound theoretical framework for expectations, allowing for the consistent implementation of valid measurement tools.


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims

We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon.

Methods

We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed.


Robotic assisted surgery aims to reduce surgical errors in implant positioning and better restore native hip biomechanics compared to conventional techniques for total hip arthroplasty (THA). The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual THA versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, cup inclination, cup version, and leg-length correction.

This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. All operative procedures were undertaken by a single surgeon using the minimally-invasive posterior approach. Two independent blinded observers recoded all radiological outcomes of interest using plain radiographs. Patients in both treatment groups were well-matched for age, gender, body mass index, laterality of surgery, and ASA scores.

Interclass correlation coefficient was 0.92 (95% CI: 0.84 – 0.95) for intra-observer agreement and 0.88 (95% CI: 0.82–0.94) for inter-observer agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p<0.001) and vertical (p<0.001) centres of rotation, and improved preservation of the patient's native combined offset (P<0.001) compared to conventional THA. Robotic THA improved accuracy in positioning of the acetabular cup within the combined safe zones of inclination and anteversion described by Lewinnek et al (p=0.02) and Callanan et al (p=0.01) compared to conventional THA (figures 1–2). There was no difference between the two treatment groups in achieving the planned leg-length correction (p=0.10).

Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular cup positioning within the safe zones of inclination and anteversion compared to conventional manual THA.

Robotic-arm assisted THA enables improved preservation of native hip biomechanics compared to conventional manual THA.

For any figures or tables, please contact authors directly: fsh@fareshaddad.net


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 45 - 45
1 Jun 2017
Konan S Eyal G Witt J
Full Access

Clinical graphics allows creation of three dimensional simulation based on CT or MRI that allows pre-operative planning. The software reports several hip morphological parameters routinely. Our aim was to validate the measurements of acetabular morphological parameters using CT based clinical graphics in patients presenting with symptomatic hip pain.

We reviewed standardised plain radiographs, CT scans and 3D clinical graphics outputs of 42 consecutive hips in 40 patients presenting with symptomatic hip pain. Acetabular index (AI), lateral centre edge angle (LCE), acetabular and femoral version measurements were analysed for the 3D clinical graphics with radiographs and CT as gold standard.

Significant differences were noted in measurements of AI, LCE, acetabular version and femoral version using the 3D motion analysis versus conventional measures, with only acetabular version showing comparable measurements. Correlation between 3D clinical graphics and conventional measures of acetabular morphology (AI, LCE) showed only slight agreement (ICC <0.4); while substantial agreement was noted for acetabular and femoral version (IC > 0.5).

Acetabular morphological parameters measured by 3D clinical graphics are not reliable or validated. While clinicians may pursue the use of 3D clinical graphics for preoperative non-invasive planning, caution should be exercised when interpreting the reports of hip morphological parameters such as AI and LCE.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 42 - 42
1 Jun 2016
Volpin A Konan S Tansey R Haddad F
Full Access

Introduction

Acetabular revision surgery is becoming more prevalent with an estimated increase of 137% by 2030. It is challenging surgery especially in the presence of deficient bone loss. Several techniques of acetabular reconstruction are used world-wide. The greater the bone loss (Paprosky Type IIIA and IIIB, and AAOS Classification of Acetabular Bone Loss Type 3 and 4) the more complex are the reconstruction methods. There is however, insufficient literature comparing the contemporary techniques of revision acetabular reconstruction and their outcomes.

Objectives

The purpose of this study was to systematically review the literature and to report clinical outcomes and survival of contemporary acetabular revision arthroplasty techniques (tantalum metal (TM) systems, uncemented revision jumbo cups, reinforced devices such as cages and rings, oblong cups and custom-made triflange cups). We specifically looked at outcomes when reconstruction was undertaken in the presence of bone loss.