header advert
Results 1 - 6 of 6
Results per page:
Applied filters
Content I can access

General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 29 - 29
1 Feb 2016
Stindel E Lefevre C Brophy R Gerard R Biant L Stiehl J Matava M
Full Access

Opening-wedge High Tibial Osteotomy (HTO) has been shown to be an effective procedure to treat mild to moderate osteoarthritis of the medial compartment of the knee in active individuals. It has also become a mandatory surgical adjunct to articular cartilage restoration when there is preoperative mal-alignment. However, its efficacy is directly correlated with the accuracy of the correction, which must be within 3° of the preoperative target. Achieving this goal is a significant challenge with conventional techniques. Therefore, computer-assisted navigation protocols have been developed; however, they do not adequately address the technical difficulties associated with this procedure. We present an integrated solution dedicated to the opening-wedge HTO. Advantages to the technique we propose include: 1) a minimum number of implanted bone trackers, 2) depth control of the saw, 3) improved 3-D accuracy in the location of the lateral tibial hinge, and 4) micrometric adjustment of the degree of correction. The proof of concept has been completed on all six specimens. The following key points have been validated: a) Compatibility with a minimally-invasive (5–6 cm) surgical incision b) The compact navigation station can be placed close to the operative field and manipulated through a sterile draping device c) Only two trackers are necessary to acquire the required landmarks and to provide 3-D control of the correction. These can be inserted within the surgical wound without any secondary incisions d) The optimised guide accurately controlled the external tibial hinge in all six cases e) The implant cavity could be milled effectively f) The distractor used to complete the desired realignment maintained stability of the distraction until final fixation with the PEEK implant g) The PEEK implant could be fixed to the tibia with excellent stability in a low-profile fashion. The solution presented here has the potential to help surgeons perform a medial opening-wedge HTO more safely and accurately. This will likely result in an increase in the number of HTOs performed for both isolated medial compartment osteoarthritis as well as for lower extremity realignment in association with cartilage restorative procedures.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 14 - 14
1 Jun 2013
Hindle P Biant L Hall A
Full Access

This study investigated confocal laser scanning microscopy (CLSM) as a novel method of imaging of chondrocytes on a collagen membrane used for articular cartilage repair. Cell viability and the effects of surgery on the cells were assessed.

Cell images were acquired under four conditions: 1, Pre-operative 2, After handling 3, Heavily grasped with forceps 4, Cut around the edge. Live and dead cell stains were used. Images were obtained for cell counting and morphology. Mean cell density was 1.12–1.68 ± 0.22 × 106 cells/cm2 in specimens without significant trauma (n=25 images), this decreased to 0.253 × 106 cells/cm2 in the specimens that had been grasped with forceps (p <0.001) (5 images). Cell viability on delivery grade membrane was 86.8±2.1%. The viability dropped to 76.3 ± 1.6% after handling and 35.1 ± 1.7% after crushing with forceps. Where the membrane was cut with scissors, there was a band of cell death where the viability dropped to 17.3 ± 2.0% compared to 73.4 ± 1.9% in the adjacent area (p <0.001). Higher magnification revealed cells did not have the rounded appearance of chondrocytes.

CLSM can quantify and image the fine morphology of cells on a MACI membrane. Careful handling of the membrane is essential to minimise chondrocyte death during surgery.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 203 - 203
1 Jan 2013
Bugler K Scott C Clement N Macdonald D Howie C Biant L
Full Access

Patient expectations and their fulfilment are an important factor in determining patient-reported outcome and satisfaction of hip (THR) and knee replacement (TKR). The aim of this prospective cohort study was to examine the expectations of patients undergoing THR and TKR, and to identify differences in expectations, predictors of high expectations and the relationship between the fulfilment of expectations and patient-reported outcome measures. During the study period, patients who underwent 346 THRs and 323 TKRs completed an expectation questionnaire, Oxford score and Short-Form 12 (SF-12) score pre-operatively. At one year post-operatively, the Oxford score, SF-12, patient satisfaction and expectation fulfilment were assessed. Univariable and multivariable analysis were performed. Improvements in mobility and daytime pain were the most important expectations in both groups. Expectation level did not differ between THR and TKR. Poor Oxford score, younger age and male gender significantly predicted high pre-operative expectations (p < 0.001). The level of pre-operative expectation was not significantly associated with the fulfilment of expectations or outcome. THR better met the expectations identified as important by patients. TKR failed to meet expectations of kneeling, squatting and stair climbing. High fulfilment of expectation in both THR and TKR was significantly predicted by young age, greater improvements in Oxford score and high pre-operative mental health scores. The fulfilment of expectations was highly correlated with satisfaction.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 149 - 149
1 Jan 2013
Manelius I McQueen M Biant L
Full Access

Distal radius fractures are common, yet the long-term functional outcome of these patients is unknown. This study investigated the long-term functional outcomes after distal radius fracture (DRF) in adult patients 16–23 years following injury. Secondary aims were to establish morbidity, mortality and function related to pattern of injury and patient demographics.

Methods

622 consented adult patients with a DRF were enrolled in the study. Prospective data was recorded; patient age, mechanism of injury and fracture pattern. Patients were assessed 16–23 years post-injury. 275 patients were deceased. 194 patients were able to complete a Quick Dash (QD) validated upper limb pain and function Patient-Reported Outcome Measure (PROM). Five patients declined follow-up. Socioeconomic status was assessed using the Scottish Index of Multiple Deprivation (SIMD) 2009.

Results

The mean age at injury was 41 years for men and 64 for women in the initial cohort. 146 women and 48 men completed final follow-up. The mean age at QD assessment was 57 years for men and 76 for women; mean and median SIMD deciles were 6.7 and 7, respectively, for both genders. The mean QD score was 10.35 for all patients, with no significant gender difference (p=0.63). 85.6% (n=166) reported no or at most, mild limitation.

High socioeconomic status, absence of other injuries at DRF and age under 85 years old at follow-up was associated with better long-term function. Early function and pain predicted long-term function; comminution pattern, treatment modality as chosen by surgeon, and early complications did not. Mortality data was analysed for the deceased (n=275). The mean patient survival from DRF to death was 11 years 5 months, with no significant gender difference (p=0.43); survival was predicted by age at injury, post-treatment dorsal angulation and early function. Respiratory, cardiovascular causes and malignancy were the three most common primary causes of death.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 257 - 257
1 Sep 2012
Green K Clement N Biant L
Full Access

Introduction

It is estimated 5% of patients over 65 years receive warfarin therapy. This paper aims to analyse whether a time delay to hip fracture fixation while waiting for the patients International Normalised Ratio (INR) to return to normal increases the mortality risk.

Methods

A prospective database of 937 hip fractures was analysed. Patient demographics and time from admission to operation were recorded. The patients' INR on admission and during the preoperative period, the need for vitamin K reversal, and any postoperative thromboembolic compilations were recorded. Thirty-day mortality was obtained from the General Register Office for Scotland. Patients with a therapeutic INR were categorised into two groups: those who received vitamin K within 24 hours of admission and those who did not.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 112 - 112
1 Mar 2012
Biant L Bruce W Walker P Herrmann S Walsh W
Full Access

‘High flexion’ polyethylene tibial tray inserts are available from total knee replacement (TKR) manufacturers. There is currently no published data available that examines how much extra knee flexion these new implants give or if there are any wear consequences for the change in design. The high flexion inserts are narrower posteriorly than standard inserts and have chamfers anteriorly and on the post in cruciate sacrificing designs.

This prospective randomised controlled trial of 100 patients undergoing posterior stabilised TKR compared knee flexion, measured intra-operatively by a computer navigation system, of the standard and high flexion trial inserts in the same knee. Patients were then randomised to receive either a standard or ‘high flexion’ definitive component and the stability assessed. The post-operative knee flexion of all patients was measured at six months.

High flexion inserts did not give significantly more knee flexion than standard inserts either per-operatively at the trial insert stage, or at six months post-op and resulted in marginally more anterior draw. The average per-operative difference in flexion between standard and high flex inserts measured in the same knee was 3.2° (range -4-18°) The average knee flexion at 6 months post op was 106° for both groups. The average change in knee flexion comparing pre and post op was 2.3° for the high flex group and 0.6° for the standard insert group.

Laboratory Tek scan contact pressure analysis at the surface of the standard and high flexion designs was not significantly different, but the thinner polyethylene of the high flexion design raises questions about wear characteristics. High flexion polyethylene inserts are probably not justified in terms of improved knee flexion, but may be a useful option in certain technical circumstances during TKR such as patella baja or if the patella impinges on the post in deep flexion.