header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 57 - 57
1 Oct 2019
Broberg JS Teeter MG Lanting B Vasarhelyi EM Howard JL Yuan X Naudie DDR
Full Access

Introduction

Surgeons performing a total knee replacement (TKR) have two techniques to assist them achieve proper bone resections and ligament tension – gap balancing (GB) and measured resection (MR). GB relies on balancing ligaments prior to bony resections, whereas bony resections are made based on anatomical landmarks in MR. Many studies have been done to compare the implant migration and kinematics between the two techniques, but the results have been varied. However, these studies have not been done on modern anatomically designed prostheses using radiostereometric analysis (RSA). Anatomical designs attempt to mimic the normal knee joint structure to return more natural kinematics to the joint, with emphasis on eliminating both paradoxical anterior motion and reduced posterior femoral rollback. Given the major design differences between anatomical and non-anatomical prostheses, it is important to investigate whether one surgical technique may have advantages another. We hypothesize that there would be no difference between GB and MR techniques in implant migration, but that GB might provide better knee kinematics.

Methods

Patients were recruited to receive an anatomically designed prosthesis and randomized to groups where the GB or MR technique is used. For all patients in the study, RSA images were acquired at a 2 week baseline, as well as at 6 weeks, 3 months, and 6 months post-operatively. These images were used to collect the maximum total point motion (MTPM) of the tibial and femoral implant components relative to the bone using a model-based RSA software. A series of RSA images were also acquired at 3-months post-operatively at different knee flexion angles, ranging in 20° increments from 0° to 100°. Model-based RSA software was used to obtain the 3D positions and orientations of the femoral and tibial components, which were used to obtain the anterior-posterior (AP) contact locations for each condyle.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 52 - 52
1 Oct 2018
Naudie DD Broberg JS Howard JL Vasarhelyi EM Yuan X McCalden RW Teeter MG
Full Access

Introduction

The effectiveness of patient specific instrumentation (PSI) to perform total knee arthroplasty (TKA) remains controversial. Multiple studies have been published that reveal conflicting results on the effectiveness of PSI, but no study has analyzed the contact kinematics within knee joints replaced with the use of PSI. Since a departure from normal kinematics can lead to eccentric loading, premature wear, and component loosening, studying the kinematics in patients who have undergone TKA with PSI can provide valuable insight on the ability of PSI to improve functionality and increase longevity. The goal of the present study was to compare femoral and tibial component migration (predictive of long-term loosening and revision) and contact kinematics following TKA using conventional instruments (CI) and PSI based surgical techniques.

Methods

The study was designed as a prospective, randomized controlled trial of 50 patients, with 25 patients each in the PSI and CI groups, powered for radiostereometric analysis (RSA). Patients in the PSI group received an MRI and standing 3-foot x-rays to construct patient-specific cut-through surgical guides for the femur and tibia with a mechanical limb alignment. All patients received the same posterior-stabilized implant with marker beads inserted in the bone around the implants to enable RSA imaging. Patients underwent supine RSA exams at multiple time points (two and six weeks, three and six months, and one and two years). At 2 years post-op, a series of RSA radiographs were acquired at different knee flexion angles, ranging in 20° increments from 0° to 120°, to measure the tibiofemoral contact kinematics. Migrations of the femoral and tibial components were calculated using model-based RSA software. Kinematics were measured for each condyle for magnitude of excursion, contact location, and stability.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 26 - 26
1 Oct 2018
McCalden RW Ponnusamy K Vasarhelyi EM Somerville LE Howard JL MacDonald SJ Naudie DD Marsh JD
Full Access

Introduction

The purpose of this study is to estimate the cost-effectiveness of performing total hip arthroplasty (THA) versus nonoperative management (NM) in non-obese (BMI 18.5–24.9), overweight (25–29.9), obese (30–34.9), severely-obese (35–39.9), morbidly-obese (40–49.9), and super-obese (50+) patients.

Methods

We constructed a state-transition Markov model to compare the cost-utility of THA and NM in the six above-mentioned BMI groups over a 15-year time period. Model parameters for transition probability (i.e. risk of revision, re-revision, death), utility, and costs (inflation adjusted to 2017 US dollars) were estimated from the literature. Direct medical costs of managing hip arthritis were accounted in the model. Indirect societal costs were not included. A 3% annual discount rate was used for costs and utilities. The primary outcome was the incremental cost-effectiveness ratio (ICER) of THA versus NM. One-way and Monte Carlo probabilistic sensitivity analysis of the model parameters were performed to determine the robustness of the model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 20 - 20
1 Sep 2012
Vasarhelyi EM Thomas B Grant H Deluzio KJ Rudan JF
Full Access

Purpose

Prospective randomized intervention trial to determine whether patients undergoing rotating platform total knee arthroplasty have better clinical outcomes at two years when compared to patients receiving fixed bearing total knee arthroplasty as measured by the WOMAC, SF-36 and Knee Society (KSS) scores.

Method

67 consecutive patients (33 males and 34 females; average age 66 years) were randomized into either receiving a DePuy Sigma rotating platform (RP) total knee arthroplasty (29 patients) or a DePuy Sigma fixed bearing (FB) total knee arthroplasty (38 patients). Inclusion criteria included patients between the ages of 45–75 undergoing single-sided total knee arthoplasty for clinically significant osteoarthritic degeneration.

Pain, disability and well-being were assessed using the WOMAC, KSS, and SF-36 preoperatively and at 6 months, 1 year and 2 years post-operatively. In addition, intraoperative measures were collected. Pre-operative radiographs were analyzed using the Kellgren and Lawrence Score, modified Scotts Scoring and mechanical axis. Post-operative radiographs were collected at 1 and 2 years and analyzed to identify evidence of prosthetic loosening, implant positioning and limb alignment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 132 - 132
1 Sep 2012
Vasarhelyi EM Yach J
Full Access

Purpose

Anterior column screw fixation has been a useful tool in the management of acetabular fractures, either alone or in combination with other fixation techniques. Percutaneous insertion may be advantageous by limiting surgical dissection but little has been reported on its safety. The purpose of this study is to report on the efficacy and safety of percutaneous anterior column stabilization.

Method

In a consecutive series of 122 operatively treated acetabular fractures, 56 patients were treated with antegrade percutaneous anterior column stabilization either alone or in combination with other fixation techniques by a single surgeon (JY). The technique was selected when the anterior column portion of the fracture was undisplaced or could be reduced via indirect methods. Intraoperative fluoroscopy was used to guide the placement of either a 6.5 mm or 7.3 mm cannulated antegrade anterior column lag screw. Postoperative radiographs (anteroposterior and Judet views) were obtained in the recovery room, prior to discharge and at clinic follow up.