Kucko N Sage K Delawi D Hoebink E Kempen D Van Susante J de Bruijn J Kruyt M
Full Access

Pseudoarthrosis after spinal fusion is an important complication leading to revision spine surgeries. Iliac Crest Bone Graft is considered the gold standard, but with limited availability and associated co-morbidities, spine surgeons often utilize alternative bone grafts.

Determine the non-inferiority of a novel submicron-sized needle-shaped surface biphasic calcium phosphate (BCP<µm) as compared to autograft in instrumented posterolateral spinal fusion.

Adult patients indicated for instrumented posterolateral spinal fusion of one to six levels from T10-S2 were enrolled at five participating centers. After instrumentation and preparation of the bone bed, the randomized allocation side of the graft type was disclosed. One side was grafted with 10cc of autograft per level containing a minimum of 50% iliac crest bone. The other side was grafted with 10cc of BCP<µm granules standalone (without autograft or bone marrow aspirate). In total, 71 levels were treated. Prospective follow-up included adverse events, Oswestry Disability Index (ODI), and a fine-cut Computerized Tomography (CT) at one year. Fusion was systematically scored as fused or not fused per level per side by two spine surgeons blinded for the procedure.

The first fifty patients enrolled are included in this analysis (mean age: 57 years; 60% female and 40% male). The diagnoses included deformity (56%), structural instability (28%), and instability from decompression (20%). The fusion rate determined by CT for BCP<μm was 76.1%, which compared favorably to the autograft fusion rate of 43.7%. Statistical analysis through binomial modeling showed that the odds of fusion of BCP<μm was 2.54 times higher than that of autograft. 14% of patients experienced a procedure or possible device-related severe adverse event and there were four reoperations. Oswestry Disability Index (ODI) score decreased from a mean of 46.0 (±15.0) to a mean of 31.7 (±16.9), and 52.4% of patients improved with at least 15-point decrease.

This data, aiming to determine non-inferiority of standalone BCP<μm as compared to autograft for posterior spinal fusions, is promising. Ongoing studies to increase the power of the statistics with more patients are forthcoming.