Vol. 97-B, Issue SUPP_10 | Pages 29 - 29
1 Oct 2015
Kumar KHS Jones G Forrest N Nathwani D
Full Access

There has been a lot of focus on the value of anatomic tunnel placement in ACL reconstruction, and the relative merits of single and double bundle grafts. Multiple cadaveric and animal studies have compared the effects of tunnel placement and graft type on knee biomechanics. 45 patients who underwent ACL reconstruction were included into our study. Femoral tunnel position was analysed by two independent doctors using the radiographic quadrant method as described by Bernard et al., and the mean values calculated. Forty-one of these patients completed a KOOS questionnaire. The mean ratio ‘a’ was 26.57% and mean ratio ‘b’ was 30.04% as compared to 24.8% (+/− 2.2%) and 28.5% (+/− 2.5%) respectively quoted by Bernard et.al, as the ideal tunnel position. Only twenty-three of these femoral tunnels were in the anatomic range. Analysis of forty-one KOOS surveys (23 anatomic, 18 non-anatomic) revealed no significant difference in total score or subscales between the anatomic and non-anatomic groups (p= >0.05). Our study suggests that the ideal tunnel position, as described by Bernard et.al. may not be ideal and fixed.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 57 - 58
1 Mar 2006
Forrest N Ashcroft Murray D
Full Access

Introduction: Femoral neck failure due to avascular necrosis (AVN) is one of the most significant complications following resurfacing hip arthroplasty. It is likely that the surgical approach is one of the factors influenc-ing the development of AVN. Positron emission tomography (PET) is the only form of imaging that allows visualisation of bone metabolic activity deep to a metal surface.

Objectives: To establish the reliability and accuracy of PET using fluorine-18 to evaluate viability of the femoral head and neck after resurfacing hip arthroplasty. To assess the viability of ten proximal femora after Birmingham resurfacing hip arthroplasty via a modified lateral approach.

Design: A convenience case series of ten patients taken from the first fifteen from one orthopaedic surgeon’s experience of Birmingham resurfacing hip arthroplasty.

Setting: The PET unit of a major urban teaching hospital with a large academic orthopaedic department.

Participants: Patients that had undergone unilateral Birmingham resurfacing hip arthroplasty via a modified lateral approach were asked to volunteer for the study. The main criterion for inclusion was ease of attendance for imaging.

Intervention: Participants were given a single intravenous dose of 250MBq fluorine-18. After a period of 40 minutes uptake time, PET images of adjacent, sequential 10cm transverse sections including both acetabulae and proximal femora were obtained.

Main Outcome Measures: Images were reconstructed to allow relative quantification of uptake between operated and non-operated femoral heads and necks.

Results: PET imaging was successful in all subjects and demonstrated activity within the resurfaced femoral heads and femoral necks. No evidence of AVN was found.

Conclusions: Static positron emission tomography using fluorine-18 is an accurate and reliable method of assessing femoral head and neck viability after resurfacing hip arthroplasty. No evidence of avascular necrosis was found in this initial series of patients that had undergone Birmingham resurfacing hip arthroplasty via a modified lateral approach.