header advert
Results 1 - 10 of 10
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 52 - 52
1 Feb 2020
Lazennec J Kim Y Caron R Folinais D Pour AE
Full Access

Introduction

Most of studies on Total Hip Arthroplasty (THA) are focused on acetabular cup orientation. Even though the literature suggests that femoral anteversion and combined anteversion have a clinical impact on THA stability, there are not many reports on these parameters. Combined anteversion can be considered morphologically as the addition of anatomical acetabular and femoral anteversions (Anatomical Combined Anatomical Anteversion ACA). It is also possible to evaluate the Combined Functional Anteversion (CFA) generated by the relative functional position of femoral and acetabular implants while standing. This preliminary study is focused on the comparison of the anatomical and functional data in asymptomatic THA patients.

Material and methods

50 asymptomatic unilateral THA patients (21 short stems and 29 standard stems) have been enrolled. All patients underwent an EOS low dose evaluation in standing position.

SterEOS software was used for the 3D measurements of cup and femur orientation. Cup anatomical anteversion (CAA) was computed as the cup anteversion in axial plane perpendicular to the Anterior Pelvic Plane. Femoral anatomical anteversion (FAA) was computed as the angle between the femoral neck axis and the posterior femoral condyles in a plane perpendicular to femoral mechanical axis. Functional anteversions for the cup (CFA) and femur (FFA) were measured in the horizontal axial patient plane in standing position. Both anatomical and functional cumulative anteversions were calculated as a sum. All 3D measures were evaluated and compared for the repeatability and reproducibility

Statistical analysis used Mann-Whitney U-test considering the non-normal distribution of data and the short number of patients (<30 for each group).


Introduction

Limb-length discrepancy (LLD) is a common postoperative complication after total hip arthroplasty (THA). This study focuses on the correlation between patients’ perception of LLD after THA and the anatomical and functional leg length, pelvic and knee alignments and foot height. Previous publications have explored this topic in patients without significant spinal pathology or previous spine or lower extremity surgery. The objective of this work is to verify if the results are the same in case of stiff or fused spine.

Methods

170 patients with stiff spine (less than 10° L1-S1 lordosis variation between standing and sitting) were evaluated minimum 1 year after unilateral primary THA implantation using EOS® images in standing position (46/170 had previous lumbar fusion). We excluded cases with previous lower limbs surgery or frontal and sagittal spinal imbalance. 3D measures were performed to evaluate femoral and tibial length, femoral offset, pelvic obliquity, hip-knee-ankle angle (HKA), knee flexion/hyperextension angle, tibial and femoral rotation.

Axial pelvic rotation was measured as the angle between the line through the centers of the hips and the EOS x-ray beam source. The distance between middle of the tibial plafond and the ground was used to investigate the height of the foot.

For data with normal distribution, paired Student's t-test and independent sample t-test were used for analysis. Univariate logistic regression was used to determine the correlation between the perception of limb length discrepancy and different variables. Multiple logistic regression was used to investigate the correlation between the patient perception of LLD and variables found significant in the univariate analysis. Significance level was set at 0.05.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 8 - 8
1 Feb 2020
Lazennec J Kim Y Folinais D Pour AE
Full Access

Introduction

Post op cup anatomical and functional orientation is a key point in THP patients regarding instability and wear. Recently literature has been focused on the consequences of the transition from standing to sitting regarding anteversion, frontal and sagittal inclination. Pelvic incidence (PI) is now considered as a key parameter for the analysis of sagittal balance and sacral slope (SS) orientation. It's influence on THP biomechanics has been suggested. Interestingly, the potential impact of this morphological angle on cup implantation during surgery and the side effects on post op functional orientation have not been studied.

Our study explores this topic from a series of standing and sitting post-op EOS images

Material and methods

310 patients (mean age 63,8, mean BMI 30,2) have been included prospectively in our current post-operative EOS protocol. All patients were operated with the same implants and technique using anterior approach in lateral decubitus.

According to previous literature, 3 groups were defined: low PI less than 45° (57 cases), high PI if more than 60° (63 cases), and standard PI in 190 other cases.


Introduction

Literature describes pelvic rotation on lateral X rays from standing to sitting position. EOS full body lateral images provide additional information about the global posture. The projection of the vertical line from C7 (C7 VL) is used to evaluate the spine balance. C7 VL can also measure pelvic sagittal translation (PST) by its horizontal distance to the hip center (HC). This study evaluates the impact of a THA implantation on pelvic rotation and sagittal translation.

Materials and Method

Lumbo-pelvic parameters of 120 patients have been retrospectively assessed pre and post- operatively on both standing and sitting acquisitions (primary unilateral THA without complication). PST is zero when C7VL goes through the center of the femoral heads and positive when C7VL is posterior to the hips' center (negative if anterior). Three subgroups were defined according to pelvic incidence (PI): low PI <45°, 45°<normal PI<65° or high PI>65°.


Introduction

Optimal implant position is critical to hip stability after total hip arthroplasty (THA). Recent literature points out the importance of the evaluation of pelvic position to optimize cup implantation. The concept of Functional Combined Anteversion (FCA), the sum of acetabular/cup anteversion and femoral/stem neck anteversion in the horizontal plane, can be used to plan and control the setting of a THA in standing position. The main purpose of this preliminary study is to evaluate the difference between the combined anteversion before and after THA in weight-bearing standing position using EOS 3D reconstructions. A simultaneous analysis of the preoperative lumbo pelvic parameters has been performed to investigate their potential influence on the post-operative reciprocal femoro-acetabular adaptation.

Material and Methods

66 patients were enrolled (unilateral primary THAs). The same mini-invasive anterolateral approach was performed in a lateral decubitus for all cases. None of the patients had any postoperative complications. For each case, EOS full-body radiographs were performed in a standing position before and after unilateral THA. A software prototype was used to assess pelvic parameters (sacral slope, pelvic version, pelvic incidence), acetabular / cup anteversion, femoral /stem neck anteversion and combined anteversion in the patient horizontal functional plane (the frontal reference was defined as the vertical plane passing through centers of the acetabula or cups). Sub-analysis was made, grouping the sample by pelvic incidence (<55°, 55°–65°, >65°) and by pre-operative sacral slope in standing position (<35°, 35°–45°, >45°). Paired t-test was used to compare differences between preoperative and postoperative parameters within each subgroup. Statistical significance was set at p < 0.05.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 11 - 11
1 Apr 2018
Lazennec J Folinais D Pour AE
Full Access

Introduction

Understanding hip-spine relationships and accurate evaluation of the pelvis position are key- points for the optimization of total hip arthroplasty (THA). Hip surgeons know the importance of pelvic parameters and the adaptation mechanisms of pelvic and sub-pelvic areas. Literature about posture after THA remains controversial and adaptations are difficult to predict. One explanation can be the segmental analysis focused on pelvic parameters and local planning.

In a significant number of patients a global analysis may be important as a cascade of compensatory mechanisms is implemented, the hip being only one of the links of this chain reaction.

3 parameters can be measured on full body images:

SVA (sagittal vertical axis) : horizontal distance between the vertical line through the center of C7 and the postero-superior edge of S1.

T1 pelvic angle (TPA) : line from femoral heads to T1center and line from the femoral heads to S1center. TPA combines informations from both the sagittal vertical axis and pelvic tilt.

Global Sagittal Angle (GSA) : line from the midpoint of distal femoral condyles to C7 center and line from the midpoint between distal femoral condyles to the postero-superior S1corner.

The objective of this preliminary study is to report the post-operative evolution of posture after THA.

Material and Method

49 patients (28 women, 21 men, mean age 61 years) were enrolled for full-body standing EOS images before and after THA. The sterEOS software was used to measure pelvic parameters (sacral slope SS, pelvic incidence PI) and global postural parameters (TPA, GSA, SVA).

Sub-analysis was made, grouping the sample by TPA (<14°, 14°–22°, >22°), by PI (<55°, 55°–65°, >65°) and by SS (<35°, 35°–45°, >45°). Paired t-test was used to compare differences between preoperative and postoperative parameters within each subgroup. Statistical significance was set at p < 0.05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 104 - 104
1 Feb 2017
Lazennec J Thauront F Folinais D Pour A
Full Access

Introduction

Optimal implant position is the important factor in the hip stability after THA. Both the acetabular and femoral implants are placed in anteversion. While most hip dislocations occur either in standing position or when the hip is flexed, preoperative hip anatomy and postoperative implants position are commonly measured in supine position with CT scan. The isolated and combined anteversions of femoral and acetabular components have been reported in the literature. The conclusions are questionable as the reference planes are not consistent: femoral anteversion is measured according to the distal femoral condyles plane (DFCP) and acetabulum orientation in the anterior pelvic plane (APP)). The EOS imaging system allows combined measurements for standing position in the “anatomical” reference plane or anterior pelvic plane (APP) or in the patient “functional” plane (PFP) defined as the horizontal plane passing through both femoral heads. The femoral anteversion can also be measured conventionally according to the DFCP. The objective of the study was to determine the preoperative and postoperative acetabular, femoral and combined hip anteversions, sacral slope, pelvic incidence and pelvic tilt in patients who undergo primary THA.

Material and Methods

The preoperative and postoperative 3D EOS images were assessed in 62 patients (66 hips). None of these patients had spine or lower extremity surgery other than THA surgery in between the 2 EOS assessments. None had dislocation within the follow up time period.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 105 - 105
1 Feb 2017
Lazennec J Fourchon N Folinais D Pour A
Full Access

Introduction

Limb length discrepancy after THA can result in medicolegal litigation. It can create discomfort for the patient and potentially cause back pain or affect the longevity of the implant. Some patients tolerate the length inequality better compared to others despite difference in anatomical femoral length after surgery.

Methods and materials

We analyzed the 3D EOS images of 75 consecutive patients who underwent primary unilateral THA (27 men, 48 women). We measured the 3D length of the femur and tibia (anatomical length), the 3D global anatomical length (the sum of femur and tibia anatomical lengths), the 3D functional length (center of the femoral head to center of the ankle), femoral neck-shaft angle, hip-knee-ankle angle, knee flexum/recurvatum angle, sacral slopes and pelvic incidence. We correlated these parameters with the patient perception of the leg length.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 140 - 140
1 May 2016
Lazennec J Tahar IN Folinais D
Full Access

Introduction

EOS® is a low dose imaging system which allows the acquisition of coupled AP and lateral high-definition images while the patient is in standing position. HipEos has been developped to perform pre-surgical planning including hip implants selection and virtual positioning in functional weight-bearing 3D. The software takes advantage of the real size 3D patient anatomical informations obtained from the EOS exam. The aim of this preliminary study on 30 consecutive THP patients was to analyze the data obtained from HipEos planning for acetabular and femoral parameters and to compare them with pre and post-operative measurements on standing EOS images.

Material and methods

Full body images were used to detect spino-pelvic abnormalities (scoliosis, pelvic rotation) and lower limbs discrepancies. One surgeon performed all THP using the same type of cementless implants (anterior approach, lateral decubitus). The minimum delay for post-op EOS controls was 10 months. A simulation of HipEos planning was performed retrospectively in a blinded way by the same surgeon after the EOS controls. All measurements were realized by an independent observer. Comparisons were done between pre and post-op status and the “ideal planning” taking in account the parameters for the restitution of joint offset and femur and global limb lengths according to the size of the selected implants. Regarding cup anteversion, the data included the anatomical anteversion (with reference to the anterior pelvic plane APP) and functionnal anteversion (according to the horizontal transverse plane in standing position).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 141 - 141
1 May 2016
Lazennec J Tahar IN Brusson A Folinais D Pour AE
Full Access

Introduction

The combination of spinal fusion and THP is not exceptional. Disorders of the pelvic tilt and stiffness of the lumbosacral junction modify the adaptation options while standing or sitting. Adjusting the cup can be difficult and THP instability is a potential risk. This study reports an experience with EOS® simultaneous measurements on AP and lateral views of spine and hips in THP patients.

Material and methods

29 men and 45 women were included in this prospective study. 21cases had bilateral THP. Patients were separated into two groups: long fusions including the thoraco-lumbar junction (group 1) and shorter fusions below L1 (group 2). We analyzed the impact of the arthrodesis on the position of the pelvis by measuring variations of the sacral slope (SS) and APP angle. Cup position was defined by coronal inclination and functional anteversion in the horizontal plane standing and sitting. We compared the data to a previous series of 150 THP patients with asymptomatic and non fused spine.