Ferrett A D'Arrigo C MOonaco E Maestri B Conteduca F
Full Access

Introduction

The Segond's fracture is described as a cortical avulsion of the lateral tibial plateau at the site of insertion of the middle third of the lateral capsular ligament. The Segond's fracture is usually associated with a tear of the Anterior Cruciate Ligament (ACL) and it is considered as an indirect radiological sign of complete rupture of the ACL. However there are no studies investigating the effect of a Segond's fracture on the kinematic of the knee especially on the rotatory instability and Pivot Shift (PS) phenomenon. The purpose of this study is to investigate the effect of a Segond's fracture on the kinematic of the knee with the use of navigation and the PS test.

Methods

Ten whole fresh-frozen cadavers were used. A navigator (2.0 Orthopilot Navigation System, BBraun Aesculap, Tuttlingen, Germany) was used to measure maximum manual Anterior Tibial Translation (ATT) at 30°, 60° and 90° of flexion, maximum manual Internal Rotation (IR) and maximum manual External Rotation (ER) at 0°, 15°, 30°, 45° and 90° of flexion. All procedures were performed three times and the mean value taken as the final result in each case. Moreover a PS test was performed by the senior, most experienced, surgeon, and graded as mild (gliding), moderate (jerk) and severe (subluxation). Navigation measurements and PS tests were performed in each knee with ACL intact, after arthroscopic cutting of the entire ACL and after a Segond's fracure was produced by exposing the antero lateral compartment of the knee underneath the ileo-tibial tract. Statistical analysis was performed using ANOVA 1-way and MANOVA tests and value for statistical analysis was set at p<0.05