header advert
Results 1 - 4 of 4
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 35 - 35
1 Apr 2018
Ko J Wang F Lee S Siu K Chou W Wang C
Full Access

Introduction

Blood loss after TKA varied, but not uncommon with up to 1500 ml or a decrease in hemoglobin of 3–4 g/dL. In addition to improving prosthetic alignment, computer-assisted TKAs also contribute to reduced operative blood loss and systemic emboli. These observations imply that navigation TKAs may cause less microvascular endothelial damage than conventional TKAs. Cell adhesion molecules (CAMs) have been employed as markers for endothelial or vascular damage. We hypothesized serum levels of CAMs in patients receiving navigation TKAs may be different from those receiving conventional TKAs.

Material and Methods

A prospective comparative study, enrolling 87 patients with osteoarthritic knees was conducted. There were 54 navigation TKAs and 33 conventional TKAs. Levels of cell adhesion molecules (CAM) in sera and hemovac drainage were measured by ELISA before and 24 hours after the surgery. Hb and Ht were checked pre- and post-operatively. The blood loss was calculated though the formula by Nadler and Sehat et al.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 116 - 116
1 Jan 2016
Chou W Chien A Wang J
Full Access

PEEK rods construct has been proposed to allow better load sharing among spinal components when compared to the more traditional Titanium rods constructs. However, such proposal has largely derived from single-load in-vitro testing and the biomechanical differences between the two constructs when subjected to fatigue loading remain unknown. Current study comparatively analyzed the in-vitro biomechanical performance of PEEK and Titanium rod constructs as spinal implants through a 5 hour fatigue loading test. The disc height and intradiscal pressure of the instrumented and adjacent levels pre- and post-loading were recorded for analysis. The stress levels on the rods and bone stress near the screw-bone interface were also collected to investigate the likely failure rates of the two constructs. The results showed that the Titanium rods construct demonstrated a minimum amount of loss of disc height and intradiscal pressure at the instrumented level, however, a significant loss of the disc height and intradiscal pressure at adjacent levels compared to the intact spine were identified. In contrast, the disc height and intradiscal pressure of the PEEK rods were found to be comparable to those of the intact spine for all levels. The PEEK rods group also showed significantly less bone stress near the screw-bone interface compared to the Titanium rods group. Current study has demonstrated the potential benefits of the PEEK rods construct in reducing the risks of adjacent segment disease and implant failure rates when compared to the more traditional Titanium rods construct.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 33 - 33
1 Oct 2014
Siu K Ko J Wang F Wang C Chou W
Full Access

D-dimer is one of the useful laboratory tests to evaluate the incidence of venous thromboembolism (VTE) after the total knee arthroplasty (TKA). The most recent guideline for the prophylaxis of VTE points out the surgical procedure itself is a major risk factor for developing VTE.

Only a few literatures discuss the relationship of surgical procedures and the risk of venous thromboembolism. We therefore prospectively compare the difference of the perioperative plasma D-dimer levels between the patients undergoing navigation and convention TKA.

Two hundred consecutive total knee arthroplasties were performed between September 2011 and March 2013. The patients were randomised according to their registration to the orthopaedic clinic. Ninety-six patients (100 knees) underwent a navigation-assisted TKA and ninety-four patients (100 knees) had a conventional TKA. No intramedullary violation was done in the navigation-assisted TKA, while the intramedullary femoral guiding was adapted in the conventional group.

Pre-operative and post-operation day 1 plasma D-dimer levels were recorded and evaluated using Mann-Whitney U test. There was no difference in the demographic data and pre-operative D-dimer between the two groups (p=0.443). Significantly lower D-dimer levels on the post-operative day 1 were noted in the navigation group, when compared with the conventional group. (6.0 ± 4.4 mg/L vs 11.3 ± 9.6 mg/L, p = 0.000).

We demonstrated that lower D-dimer level is developed after the navigation-assisted TKA than the conventional one. Less incidence of VTE is expected and the finding may help to explain the fact that less systemic emboli in the navigation assisted TKA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 421 - 421
1 Nov 2011
Wang C Chen J Hsu S Wong T Chou W
Full Access

This study compared the functional outcomes of total hip arthroplasty (THA) in one hip and extracorporeal shockwave (ESWT) in the other hip in patients with bilateral hip necrosis.

Seventeen patients with bilateral hip necrosis were treated with THA for late stage ONFH in one hip and ESWT for early lesion in the other hip. In THA, only one type of prosthesis was used and all components were cementless. In EWST, each hip received 6000 shocks at 28 Kv (equivalent to 0.62 mJ/mm2 energy flux density) in a single session. The evaluations included pain score, Harris hip score, radiographs and MR images at 6 and 12 months and then yearly.

Significant improvements in pain score and Harris hip score were noted after treatment in both hips. However, the magnitudes of improvement showed significant differences between the two sides favoring the ESWT side. On subjective assessment, 13 patients rated ESWT better than THA; 4 patients reported comparable results of THA and ESWT, and none graded THA better than ESWT. In THA side, abnormal radiographs were noted in 47% (8 of 17) including component mal-position, nonprogressive radiolucency, and suspected component loosening. In ESWT side, significant reduction of bone marrow edema and a trend of decrease in the size of the lesion were observed after treatment.

ESWT and THA are effective for early and late stages of ONFH respectively.

However, better functional outcomes were observed in ESWT-treated hips than hips treated with THA in patients with bilateral hip disease in short-term.