Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 33 - 33
1 Jul 2020
Palmer J Wilson C Wilson D Garrett S
Full Access

Background

Orthopaedic surgeons are exposed to high levels of noise when performing common surgical procedures. Noise induced hearing loss (NIHL) has been demonstrated amongst senior orthopaedic staff. The objective of this study was to investigate the prevalence of hearing loss amongst arthroplasty surgeons compared to non-surgical clinicians and explore the factors associated with hearing loss.

Methods

A cross-sectional prevalence study. Arthroplasty surgeons and non-surgical clinicians were recruited from orthopaedic and medical conferences.

All participants were given a paper questionnaire including demographic details, hearing history and Tinnitus and Hearing Survey (THS). All participants were screened for hearing loss in a quiet room using the HearCheck Screener™ (Siemens, UK).

Logistic regression was used to identify factors associated with hearing loss. All statistical models were adjusted for age, gender, smoking status and personal noise exposure. A power calculation estimated a sample size of 100 participants.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 82 - 82
1 Jan 2018
Masri B Zhang H Gilbart M Wilson D
Full Access

Cam-type femoroacetabular impingement (cam-FAI) can be treated with femoral neck osteochondroplasty to increase the clearance between the femoral head/neck and the acetabular rim. Because femur-acetabulum contact is very difficult to assess directly in patients, it is not clear if this surgery achieves its objective of reducing femur-acetabulum contact, and it is not clear how much of the femoral head/neck region should be resected to allow clearance in all activities.

Our research question was: “Does femoral neck osteochondroplasty increase femur-acetabulum clearance in an extreme hip posture in patients with cam FAI?”

We recruited 8 consecutive patients scheduled to undergo arthroscopic femoral neck osteochondroplasty to treat cam-type FAI. We assessed clearance between the acetabulum and the femoral neck before surgery and at 6 months post-op using an upright open MRI scanner that allowed the hip to be scanned in flexed postures. We scanned each subject in a supine hip flexion (90 degree), adduction and internal rotation (FADIR) posture. We measured the beta angle, which describes clearance between the acetabular rim and the femoral head/neck deformity.

Osteochondroplasty increased clearance from a mean beta angle of −9.4 degrees (SD 19.3) to 4.4 degrees (SD 16.2°) (p<0.05).

This finding suggests that femoral neck osteochondroplasty increases femur-acetabulum clearance substantially for a posture widely accepted to provoke symptoms in patients with cam-FAI.