Vol. 105-B, Issue SUPP_1 | Pages 4 - 4
23 Jan 2023
Shafafy M Shafafy R Badmus O Kapoor S
Full Access

Use of ultrasonic bone scalpel (UBS) is becoming popular in spinal surgery. This study presents the safety profile of UBS for posterior release in surgical correction of adolescent idiopathic scoliosis (AIS).

From 2016 to 2018, UBS (Misonix) was used by the senior author in a variety of spinal operations. Data for intraoperative complications when this devise was used for posterior correction of AIS were collected. Revision cases were excluded.

UBS was used for posterior release of AIS in 65 patients (58 female, seven male) with an average age of 15.6 years (range 11–23). Average length of posterior instrumentation was 12 levels (range 6–14). Instrumentation was exclusively from T2 to L4. To achieve adequate release for correction, UBS was used to perform a total of 644 modified in-situ chevron osteotomies (average ten, range six to 12) and 31 rib osteotomies. Overall, three complications (4.6 %) were directly related to the use of UBS: one haemopneumothorax, which was successfully treated with a chest drain; and two loss of motor-evoked potentials during monitoring, which led to the postponement of the final correction. These two patients did not have any neurological problems and their surgery was completed successfully within 1 week of the initial surgery. One late deep infection was reported. This was not thought to be directly related to the use of UBS.

Use of UBS in the posterior surgical treatment of AIS appears to be relatively safe with a low level of acceptable complications. However, appropriate training is required for the use of UBS.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 10 - 10
1 Sep 2021
Gadiya A Shetaiwi A Patel S Shafafy M
Full Access

Background

Partial facetectomies with pedicle screw instrumentation is widespread and a well described technique for achieving posterior correction of scoliosis. Newton et al. first described the use of the UBS in the posterior correction of AIS in 2014. The aim of this study was to compare the effectiveness of the UBSPO in achieving posterior correction in Type1 AIS as compared to the traditional partial facetectomies. Aim of this study was to assess the effectiveness of USBPO in achieving posterior correction in Type 1 AIS as compared to partial facetectomies.

Methods

A retrospective review of 40 patients with type 1 AIS who had undergone a posterior correction of scoliosis between 2010 and 2016 was performed. Group A (n=20) consisted of consecutive patients that had partial facetectomies while Group B (n=20) consisted of consecutive patients having UBSPO. Both groups were matched for demographic parameters. Pre and post-operative radiographic parameters and operative data in both groups were compared. The Mann-Whitney U test was used for statistical analysis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 26 - 26
1 Sep 2021
Palliyil N Estefan M Gessara A Shafafy M
Full Access

SUMMARY

A retrospective cohort study of 19 patients of EOS who underwent MCGR rod instrumentation with subsequent serial distractions, measured using ultrasonography. The degree of distraction achieved during each session were analyzed and subgroup analysis done.

HYPOTHESIS

The degree of distraction/ distractibility of the MCGR rod is closely linked to the etiology of EOS. The degree of distraction achieved at each session progressively diminishes with successive distractions.