header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 2 - 2
1 Jul 2022
Mohan R Staunton DM Carter JR Highcock A
Full Access

Abstract

Introduction

The UK National Joint Registry(NJR) has not reported total knee replacement (TKR)survivorship based on design philosophy alone, unlike its international counterparts. We report outcomes of implant survivorship based on design philosophy using data from NJR's 2020 annual report.

Methodology

All TKR implants with an identifiable design philosophy from NJR data were included. Cumulative revision data for cruciate-retaining(CR), posterior stabilised(PS), mobile-bearing(MB) design philosophies was derived from merged NJR data. Cumulative revision data for individual brands of implants with the medial pivot(MP) philosophy were used to calculate overall survivorship for this design philosophy. The all-cause revision was used as the endpoint and calculated to 15 years follow-up with Kaplan-Meier curves.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 5 - 5
1 Mar 2012
Cockshott S Adams D Carter S Jeys L Pynsent P
Full Access

We prospectively reviewed 2440 Cemented Anantomical (side specific) AGC total knee replacements performed on 2074 patients between 2002 and 2008 in our unit. The surgery was performed by a number of surgeons, both Consultant and Trainee grades. 1357 underwent PCL sacrificing surgery with implantation of Posterior Stabilised Femoral Implant (Cam and Grove) and 1083 underwent PCL retaining surgery with implantation of a Non-Stabilised Femoral Implant. The mean age at date of surgery for Posterior Stabilised prosthesis was 69 years (range 23-94) and Non-Posterior Stabilised prosthesis was 70 (range 33-97) with no significant difference p< 0.05 (C.I 95%). Follow up at present mean 4 years (range 1-6 years).

11 patients underwent secondary patella resurfaced for anterior knee pain at a mean of 1.5 years following the index procedure (range 0.5-4.1 years) with 6 patients reporting a marked improvement in anterior knee pain post operatively. 3 patients underwent removal of patella buttons for symptomatic loosening at a mean of 2.7 years follow index procedure.

A total of 17 patients underwent a revision of either tibial or femoral components (0.7%). Indications for revision were infection in 11 patients, gross instability in 1 patient, periprosthetic fracture in 1 patient, persistent stiffness in 1 patient. 3 patients underwent revision for symptomatic loosening of the tibial component at a mean of 2.9 years (range 1.1-4.0).

These short to medium term results for the Anatomic AGC total knee replacement agree with published results from other centres.