header advert
Results 1 - 3 of 3
Results per page:
Applied filters
Content I can access

Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 24 - 24
2 Jan 2024
Burgos J Mariscal G Antón-Rodrigálvarez L Sanpera I Hevia E García V Barrios C
Full Access

The aim of this study was to report the restauration of the normal vertebral morphology and the absence of curve progression after removal the instrumentation in AIS patients that underwent posterior correction of the deformity by common all screws construct whitout fusion. A series of 36 AIS immature patients (Risser 3 or less) were include in the study. Instrumentation was removed once the maturity stage was complete (Risser 5). Curve correction was assessed at pre and postoperative, before instrumentation removal, just post removal, and more than two years after instrumentation removal. Epiphyseal vertebral growth modulation was assessed by a coronal wedging ratio (WR) at the apical level of the main curve (MC). The mean preoperative coronal Cobb was corrected from 53.7°±7.5 to 5.5º±7.5º (89.7%) at the immediate postop. After implants removal (31.0±5.8 months) the MC was 13.1º. T5–T12 kyphosis showed a significant improvement from 19.0º before curve correction to 27.1º after implants removal (p<0.05). Before surgery, WR was 0.71±0.06, and after removal WR was 0.98±0.08 (p<0.001). At the end of follow-up, the mean sagittal range of motion (ROM) of the T12-S1 segment was 51.2±21.0º. SRS-22 scores improved from 3.31±0.25 preoperatively to 3.68±0.25 at final assessment (p<0.001). In conclusion, fusionless posterior approach using a common all pedicle screws construct correct satisfactory scoliotic main curves and permits removal of the instrumentation once the bone maturity is reached. The final correction was highly satisfactory and an acceptable ROM of the previously lower instrumented segments was observed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 59 - 59
1 Apr 2017
Hernandez C Burgos J Antón L García V Hevia E Barrios C
Full Access

Background

The improvement of the rib cage deformity (RCD) after surgery correction has not been correlated in detail with the correction of vertebral axial rotation (AR). The loss of at the rib cage after correction has been never monitored. The hypothesis of this work was that the aesthetic improvement of RCD in adolescent idiopathic scoliosis (AIS) does not follow completely the reduction of thoracic AR after correction surgery. Moreover, lesser correction of thorax deformity could be expected in mature patients with more rigid curves.

Methods

Multicenter prospective study of the modifications of the rib cage deformity in 24 patients operated because of AIS Lenke type 1A. RDC was assessed in the preoperative MRI exams including the thoracic perimeter. Vertebral AR was quantified by the RaSac angle. Anterior and posterior rib hump, and the translation of the sternum were measured in mm according to standard protocols. All these parameters were assessed in the immediate post-op period and 2-years after surgery using CT-scan axial slides. In all cases, a vertebral derotation technique performed by asymmetric rod bending was used. Immature (Risser 0–2) and mature (Risser 3–4) patients were compared.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 61 - 61
1 Apr 2017
Antón-Rodrigálvarez LM Flores JB Cabanes L Barrios C Hevia E de Blas G García V
Full Access

Background

The overall incidence of neurological symptoms attributed to lumbar misplaced screws has been described to occur in 3.48% of patients undergoing surgery. These lumbar radicular neurological lesions are undetected with conventional intraoperative neurophysiological and radiological controls. The hypothesis of this study was that direct stimulation of the pedicle screw after placement in the lumbar spine may not work as well as for screws placed in the thoracic pedicles. A more suitable method for the lumbar spine could be the stimulation of the pedicle track with a ball-tipped probe.

Methods

Comparative observational study on the detection of malpostioned lumbar pedicle screws using two different techniques in two different periods: t-EMG screw stimulation (2011–2012) and track stimulation (2013–2014). A total of 1440 lumbar pedicle screws were placed in 242 patients undergoing surgery for vertebral deformities in the last four years (2011–2014). In the first two years, 802 lumbar screws were neuromonitored using t-EMG during. In the last two years, 638 screws were placed after probe stimulation of the pedicle track. Standardised t-EMG conventional registration and fluoroscopy were afterwards performed in all cases.