The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue. A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.Objectives
Methods
The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress. It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used versus use of pulsatile saline lavage alone. Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.
Total knee arthroplasty (TKA) is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity. A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity. Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS. Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leucocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment, and MARS MRI. More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11- 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimization of patient co-morbidities to help avoid preventable complications, use of pre-operative and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.
Registry data from around the world demonstrates instability following primary THA is a leading indication for revision. However, the burden of THA dislocation is poorly documented and is not routinely recorded or reported at a national level. Our aim was to determine the rate of dislocation following primary THA in contemporary practice and in doing so determining the burden of THA dislocation to the NHS in Wales. We considered all Welsh residents who underwent primary THA from 2011–2016. Via clinical coding linkage using Patient Episode Database for Wales (PEDW), the equivalent of HES data in England, we were able determine re-admission for dislocation, revision THA following dislocation and all cause revision at 1 to 5 years follow-up.Introduction
Method
Short bone-conserving femoral stem implants were developed to achieve more physiological, proximal bone loading than conventional femoral stems. Concerns have arisen, however, that improved loading may be offset by lower primary stability because of the reduced potential area for bony contact. The aim of this study was to determine the primary stability of a novel short femoral stem compared with a conventional femoral stem following cementless total hip arthroplasty (THA), in a prospective, blinded, randomised, controlled trial using radiostereometric analysis.Background
Aims
A patient in his thirties developed synovitis with grade 4 chondrolysis and a stiff knee with a fixed flexion deformity between three and six years following PLC and PCL reconstruction using LARS (Ligament Augmentation and Reconstruction System, Corin). There was histologic evidence of foreign body reaction, the knee was painful, swollen and stiff. We did not use any further LARS ligaments for soft tissue reconstructions of the kneein our practice. We commenced a recall programme for all 83 patients patients who underwent a soft tissue knee reconstruction using LARS. Of those contacted, 41 replied (49%) and 16 patients had symptoms (19%) and were investigated further with XRay, MRI and arthroscopy as indicated. We discovered a total of five patients had histologically proven synovitis with foreign body reactions (6%), three of whom had life-changing symptomatic pain, swelling and stiffness with degenerate changes (3.6%). These patients had undergone various reconstructions, including a) PLC only, b) ACL and PCL, c) PCL and PLC and d) ACL, PCL and PLC. A further single case of massive bone cyst formation was noted, following PCL reconstruction using LARS (1.2%).
Up to 60% of total hip arthroplasties (THA) in Asian populations arise from avascular necrosis (AVN), a bone disease that can lead to femoral head collapse. Current diagnostic methods to classify AVN have poor reproducibility and are not reliable in assessing the fracture risk. Femoral heads with an immediate fracture risk should be treated with a THA, conservative treatments are only successful in some cases and cause unnecessary patient suffering if used inappropriately. There is potential to improve the assessment of the fracture risk by using a combination of density-calibrated computed tomographic (QCT) imaging and engineering beam theory. The aim of this study was to validate the novel fracture prediction method against Six femoral heads from six subjects were tested, a subset (n=3) included a hole drilled into the subchondral area of the femoral head via the femoral neck (University of Leeds, ethical approval MEEC13-002). The simulated lesions provided a method to validate the fracture prediction model with respect of AVN. The femoral heads were then modelled by a beam loaded with a single joint contact load. Material properties were assigned to the beam model from QCT-scans by using a density-modulus relationship. The maximum joint loading at which each bone cross-section was likely to fracture was calculated using a strain based failure criterion. Based on the predicted fracture loads, all six femoral heads (validation set) were classified into two groups, high fracture risk and low fracture risk (Figure 1). Beam theory did not allow for an accurate fracture load to be found because of the geometry of the femoral head. Therefore the predicted fracture loads of each of the six femoral heads was compared to the mean fracture load from twelve previously analysed human femoral heads (reference set) without lesions. The six cemented femurs were compression tested until failure. The subjects with a higher fracture risk were identified using both the experimental and beam tool outputs.Introduction
Methods
There are many surgical, implant design and patient factors that should be considered in preclinical testing of hip replacement which are not being considered in current standards. The aim of this study was to develop a preclinical testing method that consider surgical positioning, implant design and patient factors and predict the occurrence and severity of edge loading under the combination of such conditions. Then, assess the safety and reliability of the implant by predicting the wear, deformation and damage of the implant bearings under worst case conditions. Ceramic-on-ceramic (CoC, 36mm, BIOLOX® delta, Pinnacle®, DePuy Synthes, UK) and metal-on polyethylene (MoP, 36mm, Marathon®, Pinnacle®, DePuy Synthes, UK) bearings were used for this study on multi-station multi-axis hip joint simulators. Two factors were varied, cup inclination angles (45° and 65°) and translational mismatch between the femoral head and acetabular cup (0, 2, 3 and 4 (mm)). Under each condition for both CoC and MoP bearings, three million cycles of gait cycle testing were completed with wear, deformation and/or damage measurements completed at one million cycle intervals. Other outputs of the study were the level of dynamic separation between the femoral head and acetabular cup during gait, the maximum force at the rim during edge loading when the head was sliding back to the cup confinement. Means and 95% confidence limits were determined and statistical analysis were done using one way ANOVA with significance taken at p<0.05.Introduction and Aims
Methods
Geometric variations of the hip joint can give rise to repeated abnormal contact between the femur and acetabular rim, resulting in cartilage and labrum damage. Population-based geometric parameterisation can facilitate the flexible and automated Parametric geometries can be developed into finite element models to assess the potential effects of morphological variations in bone on soft tissue strains. The aim of this study was to demonstrate the capabilities of our parameterisation research tool by assessing impingement severity resulting from a range of parametrically varied femoral and acetabular geometries. Custom made MATLAB (MathWorks) and Python codes[1] were used to generate bone surfaces, which were developed into finite element models in Abaqus (SIMULIA). Parametric femoral surfaces were defined by a spherical proximal head and ellipse sections through the neck/cam region. This method produced surfaces that were well fitted to bone geometry segmented from CT scans of cam patients and capable of producing trends in results similar to those found using segmented models. A simplified spherical geometry, including the labrum and acetabular cartilage, represented the acetabulum. Femoral parameters were adjusted to define relevant variations in cam size and position. Two radii (small and large cams) and two positions (anterior and superior cams) were defined resulting in four models. Alpha angles of these parametric femurs were measured in an anterior-posterior view and a cross-table lateral view using ImageJ (NIH). A further model was developed using a femur with a medium cam size and position, and the level of acetabular coverage and labrum length were varied. Bones were modelled as rigid bodies and soft tissues were modelled as transversely isotropic linearly elastic materials. With the acetabulum fully constrained in all cases, the femurs were constrained in translation and rotated to simulate flexion followed by internal rotation to cause impingement against the labrum.Introduction
Methods
This review aims to explore the methodologies used for estimating the direct and indirect costs attributed to back pain in developed countries. Six databases were searched to uncover studies about the direct and indirect costs of back pain published in English upto November 2016. Data extracted included study characteristics, cost categories and analysis methods. Results were synthesised descriptively.Purpose
Methods
To investigate whether the duration of pain has an influence on the clinical outcomes of patients with low back pain (LBP) managed through the North East of England Regional Back Pain and Radicular Pain Pathway (NERBPP). The NERBPP is a clinical pathway based upon NICE guidelines (2009) for LBP. Patients with LBP referred onto the NERBPP by their General Practitioner (GP) between May 2015 and January 2017 were included in this evaluation. Data from 635 patients, who provided pre and post data for pain (Numerical rating scale [NRS]), function (Oswestry Disability Index [ODI]) and quality-of-life (EuroQol [EQ5D]), were analysed using a series of covariate adjusted models in SPSS. Patients were categorised into four groups based upon pain duration: <3months, ≥3 to <6months, ≥6months to <12months, ≥12months.Aims
Patients and Methods
The study sought to determine the results of labral restoration among patients over age 60 compared to a cohort of younger adults. 21 consecutive patients over age 60 undergoing labral repair with minimum one-year follow-up were compared to a contemporaneous group of 21 patients age 18–55 matched for gender, degree of chondral damage, and associated FAI or dysplasia. Follow-up averaged 18.9 months (12 to 24 months). The study group averaged 63.2 years (61 to 71); with 20 FAI and one dysplasia. 19 had acetabular articular damage (2 grade IV, 11 grade III, 5 grade II, 1 grade I) and 6 had femoral changes (1 grade IV, 5 grade 3). The control group averaged 35.8 years (20 to 54). Average improvement among the study group was 28.1 points modified Harris Hip Score (mHHS) and 37.5 points iHOT; and among the control group, 21.2 points mHHS and 37.1 points iHOT. There was no statistically significant difference between the two groups in the amount of improvement, with statistically and clinically significant improvement noted in both. Two study group patients underwent total hip arthroplasty (THA) at average 10 months with one control group THA at 11 months. All three converted to THA had combined grade IV acetabular and grade III femoral damage. There were no repeat arthroscopies and no complications in either group. We conclude that patients over age 60 can benefit from arthroscopic labral repair with improved outcomes, modest rates of conversion to THA, and small risk of complication. Results are comparable to younger adults. Combined bipolar grade IV or grade III articular damage is a harbinger of conversion to THA, regardless of age.
The pelvis is known to undergo significant movement during Total Hip Replacement (THR). We developed a 4D-tracking device employing an inertial measurement unit (IMU) to track changes in pelvic orientation during THR. The IMU was mounted on the iliac crest in 39 cases with tracking initiated at the commencement of surgery and digital logging of significant intra-operative milestones (i.e. acetabular impaction). The system was validated by videoing a select number of cases and the 4D model linked in real-time. Data were processed using a custom Java-based infrastructure to calculate roll (left/right) and tilt (flexion/extension). 19 patients underwent direct anterior approach (DAA) and 20 posterior approach (PA). Comparing DAA to PA, at acetabular impaction there was mean pelvic roll seen of 3.7°(range 0.5–10.1°) in the DAA group, and 5.6°(range 0.1–16.2°) in the PA group. Mean tilt in the DAA group was 3.7°(range: 0.2–7.1°) and in the PA group was 1.7°(range: 0.2–4.3°). Mean BMI in the DAA group was 25.2(range: 18.4–34.2) and 29.1(range: 21.5–42.4). There was no direct correlation between BMI and the amount of roll or tilt recorded for individual patients. The IMU tracking device provided a useful and real-time method of assessing pelvic orientation during THR via both the DAA and posterior approach. Specific variations in tilt and roll are consistent with previous literature. Significant variation in the pattern of pelvic movement was noted to be dependent on the approach and the position of the patient on the operating table.
The aim of this study was to determine whether patients with
metal-on-metal (MoM) arthroplasties of the hip have an increased
risk of cardiac failure compared with those with alternative types
of arthroplasties (non-MoM). A linkage study between the National Joint Registry, Hospital
Episodes Statistics and records of the Office for National Statistics
on deaths was undertaken. Patients who underwent elective total
hip arthroplasty between January 2003 and December 2014 with no
past history of cardiac failure were included and stratified as
having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty.
The primary outcome measure was the time to an admission to hospital
for cardiac failure or death. Analysis was carried out using data
from all patients and from those matched by propensity score.Aims
Patients and Methods
Osteosynthesis to conserve femoral head following neck of femur (NOF) fractures has reported failure rates of 36 to 47% at 2 years. However, the long-term outcomes of THAs performed for failed osteosynthesis is yet to be elucidated. This study aims to report on long term outcome of primary THAs post failed osteosynthesis for NOF fracture. Consecutive patients with THA for failed NOF osteosynthesis managed by a single unit between January 1974 and December 2009 were included. Clinical and radiological outcomes of all 72 patients were analysed. Patients with minimum follow-up of 5 years were included. Those with less than 5 years of follow-up were reviewed for failures.Introduction
Methods
The ideal operative treatment of displaced sub capital femoral fractures in the elderly is controversial. Recently, randomised controlled trials have suggested a better outcome with the use of total hip arthroplasty (THA) to treat displaced intra capsular fractures of the femur for elderly patients in good health. More recently the concept of dual mobility cups is being promoted to avoid dislocations in this cohort of patients. However, overall there is limited evidence to support the choice between different types of arthroplasty. Dislocation remains a main concern with THA, especially when a posterior approach is used. We analysed the outcome of 115 primary THR (112 cements and 3 uncemented) THR using a posterior approach with soft tissue repair in active elderly patients presenting with displaced intra capsular femoral neck fractures. Size 28 mm head was used in 108 and a size 32 mm head in the rest. All surgery was performed by specialist hip surgeons. Satisfactory results were noted in terms of pain control, return to pre-morbid activity and radiological evidence of bone implant osteo-integration. The 30-day mortality was nil. There were two dislocations and only one needed revision surgery due to recurrent dislocation. In conclusion, with optimal patient selection, THA seems to provide a good functional outcome and pain relief in the management of displaced intracapsular femoral neck fractures. Excellent outcome can be achieved when done well using the standard cemented THR and with 28mm head. A good soft tissue repair and a specialist hip surgeon is preferable.
Prosthetic joint infection continues to remain a diagnostic challenge for unhappy primary arthroplasty of hip and knees. There is increasing dependence upon alpha-defensin test to make key decisions like whether to revise or not & to decide between one-stage versus two-stage. This study aims to assess diagnostic accuracy of alpha-defensin test in determining prosthetic hip & knee infection and to provide guidance for appropriate use of this novel but expensive investigation. Retrospective review of all alpha-defensin investigated patients in an orthopaedic institute between February 2015 & March 2017 was performed. Clinical and radiological outcomes including re-infections, re-operations were analysed and alpha-defensin outcomes were compared with that of other available investigations.Aim
Methods
Conservative treatment of acute AT ruptures with functional rehabilitation has demonstrated superior results with equal reported re-rupture rates but without the added complications of surgical treatment. There is no consensus on the duration and method of treatment using functional rehabilitation regimes. The purpose of this paper is to define our treatment regime, the Leicester Achilles Management Protocol (LAMP), supported with patient reported outcomes and objective measures of assessment. All patients with an acute achilles tendon rupture were treated with the same non-operative LAMP functional rehabilitation regime in a VACOped boot for 8 weeks. 12 months post rupture ATRS scores and objective measures of calf muscle girth and heel raise height were obtained and analysed. Venous thromboembolic rates and rates of re-rupture were recorded.Background
Methods
One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface. Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points.Background
Methods