Advertisement for orthosearch.org.uk
Results 21 - 40 of 60
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 114 - 114
1 May 2016
Park Y Moon Y Lim S Kim S Jeong M Park S
Full Access

Introduction

As the proximal femoral bone is generally compromised in failed total hip arthroplasty, achievement of solid fixation with a new component can be technically demanding. Clinical studies have demonstrated good medium-term results after revision total hip arthroplasty using modular fluted and tapered distal fixation stems, but, to our knowledge, long-term outcomes have been rarely reported in the literature. The purpose of this study was to report the minimum ten-year results of revision total hip arthroplasty using a modular fluted and tapered distal fixation stem.

Materials & Methods

We analyzed 40 revision THAs performed in using a modular fluted and tapered distal fixation stem (Fig. 1) between December 1998 and February 2004. There were 11 men (12 hips) and 28 women (28 hips) with a mean age of 59 years (range, 38 to 79 years) at the time of revision THA. According to the Paprosky classification of femoral defects, 5 were Type II, 24 were Type IIIA, and 11 were Type IIIB. An extended trochanteric osteotomy was carried out in 21 (52%) of the 40 hips. Patients were followed for a mean of 11.7 years (range, 10 to 15 years).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 100 - 100
1 May 2016
Kim S Lim Y Kwon S Sun D Kim Y Ju S
Full Access

Introduction

The acetabular cup should be properly oriented to prevent dislocation and to reduce wear and leg length discrepancy. Despite advances in surgical techniques and instrumentation, achieving proper cup placement in total hip arthroplasty (THA) is challenging with potentially large variations of cup position and limited accuracy. We evaluated whether cup placement on anatomical location ensured original center of rotation (COR) and surgeon's experiences of THA reduced variations in acetabular component positioning.

Methods

We retrospectively reviewed 145 patients (145 hips) of unilateral THAs with normal contralateral structures of acetabulum and femoral head. All surgeries were performed using the modified posterolateral approach that preserves short external rotator muscles. All of the 145 THAs were performed by two surgeons, who were in the same teaching hospital, but had differences in surgical experience and expertise for THA. The patients were divided into two groups based upon surgical experience: (1) the highly experienced surgeon's group: who had previously performed over 1000 THAs (YSK, 101 hips), and (2) the less experienced novice's group: who had performed fewer than 30 THAs (YWL, 44 hips). Real vertical distances, from the COR to the inter-tear drop line, and the real horizontal distances, from the COR to the lateral wall of the tear drop, were measured preoperatively using picture archiving communication system (PACS) based precise method. Postoperative ones were measured and equalized by use of a magnification marker placed on preoperative plain radiographs. And cup inclination was measured directly on the AP radiographs and anteversion was calculated by trigonometric functions. The patient's mean age was 52.1 years (range, 20–86).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 53 - 53
1 May 2016
Moon Y Seo J Kim S Park J
Full Access

Background

The purpose of this study is to report the outcome of navigation-assisted cruciate-retaining total knee arthroplasty (TKA) using one type of cemented, second-generation, floating-platform (FP), mobile-bearing system.

Methods

We retrospectively reviewed 42 patients (51 knees) who underwent cruciate retaining TKAs using e.motion-FP prostheses under navigational guidance. The preoperative diagnosis was osteoarthritis in all knees except one rheumatoid arthritis. There were 2 men (2 knees) and 40 women (49 knees) with a mean age of 64.0 ± 4.7 years (range, 51 – 76 years) at the time of index surgery. The mean follow-up was 120.0 months (range, 106 – 126 months). Clinical and radiographic results as well as mechanical survival rate of this type prosthesis were investigated at a mean follow-up of 10 years.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 115 - 115
1 May 2016
Park Y Moon Y Lim S Kim S Jeong M Park S
Full Access

Introduction

Patients with osteonecrosis of the femoral head are typically younger, more active, and often require high rates of revision following primary total hip arthroplasty. However, outcomes of revision hip arthroplasty in this patient population have been rarely reported in the literature. The purpose of this study was to report the intermediate-term clinical and radiographic outcomes of revision hip arthroplasty in patients with osteonecrosis of the femoral head.

Materials & Methods

Between November 1994 and December 2009, 187 revision hip arthoplasty were performed in 137 patients who had a diagnosis of osteonecrosis of the femoral head. Exclusion criteria included infection, recurrent instability, isolated polyethylene liner exchange, and inadequate follow-up (less than 3 years). The final study cohort of this retrospective review consisted of 72 patients (75 hips) with a mean age of 53.3 years (range, 34 to 76). Components used for the acetabular revision included a cementless porous-coated cup in 58 hips and an acetabular cage in 2 hips. Components used for the femoral revision included a fully grit-blasted tapered stem in 30 hips and a proximally porous-coated modular stem in 9 hips. The mean duration of follow-up was 7 years (range, 3 to 17).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 74 - 74
1 May 2016
Kang S Chang C Choi I Woo J Woo M Kim S
Full Access

Introduction

Deformity of knee joint causes deviation of mechanical axis in the coronal plane, and the mechanical axis deviation also could adversely affect biomechanics of the ankle joint as well as the knee joint. Particularly, most of the patients undergoing total knee arthroplasty (TKA) have significant preoperative varus malalignment which would be corrected after TKA, the patients also may have significant changes of ankle joint characteristics after the surgery. This study aimed 1) to examine the prevalence of coexisting ankle osteoarthritis (OA) in the patients undergoing TKA due to varus knee OA and to determine whether the patients with coexisting ankle OA have more varus malalignment, and 2) to evaluate the changes of radiographic parameters for ankle joint before and 4 years after TKA.

Methods

We evaluated 153 knees in 86 patients with varus knee OA who underwent primary TKA. With use of standing whole-limb anteroposterior radiographs and ankle radiographs before and 4 years after TKRA, we assessed prevalence of coexisting ankle OA in the patients before TKA and analyzed the changes of four radiographic parameters before and after TKA including 1) the mechanical tibiofemoral angle (negative value = varus), 2) the ankle joint orientation relative to the ground (positive value = sloping down laterally), 3) ankle joint space, and 4) medial clear space.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 101 - 101
1 May 2016
Kim S Park Y Moon Y
Full Access

Management of the patella with poor bone stock remains a challenge in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate the results of a novel surgical technique in which widely available wires and acrylic bone cement are used in the reconstruction of a deficient patella.

Twenty-eight patients (30 knees) underwent revision TKA in which a deficient patella was treated with an onlay-type prosthesis and bone-augmenting procedure, using transcortical wiring. The technique was indicated when the thickness of remnant patella was less than 8mm with variable amounts of the peripheral rim. The remaining patellar height ranged from 3.2mm to 7.3mm. Follow-up was available for all patients with a mean of 36.6 months (range, 24 to 55 months).

The respective mean Knee Society scores for knee and function improved from 34.2 points (range, 18 to 65 points) and 23 points (range, 18 to 46 points) preoperatively to 73.5 points (range, 30 to 88 points) and 61points (range, 34 to 80 points) at final follow-up. The mean thickness of the patellar construct was 14.6mm (range, 12.2 – 18.3mm). One patient experienced patellar fracture during knee flexion one week after surgery. There were no complications associated with implanted hardware.

A patellar bone-augmenting procedure using transcortical wiring is a straightforward technique that potentially allows firm fixation. Considering the satisfactory short- to mid-term results, we believe that this technique provides a good alternative option in addressing this challenging problem in revision TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 112 - 112
1 May 2016
Park Y Moon Y Lim S Kim S Jeong M Park S
Full Access

Introduction

Modern ceramic-on-ceramic bearings have become attractive alternatives to conventional polyethylene due to their low wear and minimal particle production. However, ceramic-on-ceramic implants have been associated with ceramic fracture and squeaking. To address these issues, large ceramic heads with a titanium-alloy sleeve have been introduced although limited data are available on their clinical outcomes. The purpose of this study was to report the midterm results of primary total hip arthroplasty using a 32mm with a titanium-alloy sleeve.

Materials & Methods

We reviewed 245 patients who had 274 total hip arthroplasties with a 32 mm ceramic head with a titanium-alloy sleeve and had been followed for more than 5 years (average, 6.5 years; range, 5–9 years). The mean patient age at the time of surgery was 55.1 years (range, 16–82 years). All operations were performed at a single center. All of the ceramic implants were hot isostatic pressed, laser-marked, proof-tested third-generation alumina (Fig. 1). We determined the implant survival, Harris hip scores, incidence of ceramic fracture or noisy hips, and presence of osteolysis.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 98 - 98
1 May 2016
Kim S Park Y Moon Y Seo J
Full Access

Background

Management of the patella with poor bone stock remains a challenge in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate the results of a novel surgical technique in which widely available wires and acrylic bone cement are used in the reconstruction of a deficient patella.

Methods

Twenty-eight patients (30 knees) underwent revision TKA in which a deficient patella was treated with an onlay-type prosthesis and bone-augmenting procedure, using transcortical wiring. The technique was indicated when the thickness of remnant patella was less than 8mm with variable amounts of the peripheral rim. The remaining patellar height ranged from 3.2mm to 7.3mm. Follow-up was available for all patients with a mean of 36.6 months (range, 24 to 55 months).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 102 - 102
1 May 2016
Kim J Kim S
Full Access

Background

Theoretically, improved material properties of new alumina matrix composite (AMC) material, Delta ceramics, are expected to decrease concerns associated with pure alumina ceramics and allow manufacturing thinner liners and consequent larger heads. However, limited short-term clinical results are available and mid-term results of these effects are unclear.

Questions/Purposes

(1) Does AMC material decrease the rate of ceramic fracture and noise, concerns of previous-generation ceramics, following change of material properties? (2) Does the possible use of larger heads consequent to manufacturing thinner liners decrease dislocation rate and affect inguinal pain? (3) Do any other complications associated with the use of AMC ceramics occur?


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 78 - 78
1 May 2016
Kang S Chang C Woo J Woo M Choi I Kim S
Full Access

Introduction

Even a number of studies have reported clinical outcomes after revision total knee arthroplasty (revision TKA), little information is still available on whether outcomes of patients undergoing a revision TKA as a second stage procedure because of infected TKA are poorer than those of the patients undergoing a single-stage revision TKA because of non-infectious causes. In addition, use of various revision prostheses in most previous studies may limit solid interpretation of the outcomes after revision TKA. This study sought to determine whether outcomes in patients undergoing revision TKA due to infected TKA would be different from those in patients undergoing revision TKA due to non-infectious causes.

Materials and Methods

We assessed 71 cases undergoing revision TKAs with use of a same revision system (Scorpio TS®, Stryker, Mahwah, NJ) from October 1999 to February 2012. All patients followed more than two years and mean follow-up period was 67 months (range: 24 – 168 months). Of them, thirty five patients underwent revisions due to infected TKA (group for infected TKA) while 36 patients due to non-infectious causes including loosening, wear, and/or instability (group for non-infected TKA). All patients in the group for infected TKA underwent two-stage revision surgeries while all patients in the group for non-infected TKA single stage revision surgeries. Comparative variables between two groups were preoperative range of motion (ROM) and American knee society (AKS) scores, postoperative ROM and AKS scores assessed at latest follow-up, amount of bone loss and requirement of stem assessed during the surgeries, and survival rate.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 113 - 113
1 May 2016
Park Y Moon Y Lim S Kim S Jeong M Park S
Full Access

Introduction

Highly cross-linked polyethylene has been introduced to decrease osteolysis secondary to polyethylene wear debris generation, but there are few long-term data on revision total hip arthroplasty using highly cross-linked polyethylene liners. The purpose of this study was to report the long-term radiographic and clinical outcomes of a highly cross-linked polyethylene liner in revision total hip arthroplasty.

Materials & Methods

We analyzed 63 revision total hip arthoplasties that were performed in 63 patients using a highly cross-linked polyethylene liner between April 2000 and February 2005. Of these, nine died and four were lost to follow-up before the end of the 10-year evaluation. Thus, the final study cohort consisted of 50 patients (50 hips). There were 26 males and 24 females with a mean age at time of revision total hip arthoplasty of 53 years (range, 27–75 years). Mean duration of follow-up was 11 years (range, 10–14 years).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 79 - 79
1 May 2016
Kang S Chang C Woo M Woo J Choi I Kim S
Full Access

Introduction

Total knee arthroplasty (TKA) is a proven treatment method for advanced knee arthritis in terms of pain relief, function restoration, and quality-of-life improvement. The TKA use has increased significantly over the past decade and the growing rate is more prominent in Asian countries. Thus, the revision TKA may also increase in recent days, which represents a burden to the national health care system. To the best of our knowledge, little information is currently available regarding the incidence and related factors of revision TKA in Asian countries on the basis of nationwide database. This study sought to find the incidence of revision TKA and related factors in South Korea using national database from 2007 to 2012.

Material and Method

Data collected by the Health Insurance Review Agency of Korea, from 260,068 TKA patients between 2007 and 2012, were used to estimate the incidence of revision TKA according to age group, gender and hospital TKA and manufacturer prosthesis volume (i.e., the number of TKA procedures carried out at a given hospital, and the number of procedures performed using a given manufacturer's prosthesis, respectively). Age group and hospital and manufacturer volumes were categorized into three groups and TKA incidence rates were computed for groups stratified according to age, gender and hospital and manufacturer volumes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 2 - 2
1 May 2016
Lim Y Kwon S Sun D Kim S Kim J Choi S Kim Y
Full Access

Introduction

3-D Printing with direct metal tooling (DMT) technology was innovatively introduced in the field of surface treatment of prosthesis to improve, moreover to overcome the problems of plasma spray, hopefully resulting in opening the possibility of another page of coating technology. We presumed such modification on the surface of Co-Cr alloy by DMT would improve the ability of Co-Cr alloys to osseointegrate.

Method

We compared the in vitro and in vivo ability of cells to adhere to DMT coated Co-Cr alloy to that of two different types of surface modifications: machined and plasma spray(TPS). We performed energy-dispersive x-ray spectroscopy and scanned electron microscopy investigations to assess the structure and morphology of the surfaces. Biologic and morphologic responses to osteoblast cell lines of human were then examined by measuring cell proliferation, cell differentiation (alkaline phosphatase activity), and avb3 integrin. The cell proliferation rate, alkaline phosphatase activity, and cell adhesion in the MAO group increased in comparison to those in the machined and grit-blasted groups.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 52 - 52
1 May 2016
Moon Y Park J Seo J Jang M Kim S
Full Access

Introduction

We sought to determine the 10-year survivorship of single-radius, posterior-stabilized total knee arthroplasty (TKA) in Asian patients. We also aimed to determine whether the long-term clinical and radiographic results differed between patients with and without patellar resurfacing.

Materials and Methods

This retrospective study included 148 (115 patients) consecutive single-radius, posterior-stabilized TKAs. Ten-year survivorship analysis was performed using the Kaplan-Meier method with additional surgery for any reason as the end-point. Furthermore, long-term clinical and radiographic results of 109 knees (74%; 84 patients) with more than a 10-year follow-up were analyzed. Ten-year survivorship and long-term outcomes after surgery were determined, and outcomes were compared between patients with and without patellar resurfacing.


Introduction

We describe a single stage arthroscopic procedure for the treatment of articular cartilage defects in the knee. The novel procedure involves microdrilling and application of atellocollagen and fibrin gel. The aim of the study was to evaluate the clinical outcomes at 4 years.

Materials and Methods

A prospective study of 30 patients with symptomatic ICRS grade III/IV chondral defects which were assessed clinically and radiologically. The lesions were located on the MFC, LFC, trochlea or patella, ranging from 2–8cm2. The surgical procedure involved debridement of the lesion, microdrilling and application of atellocollagen and fibrin gel under CO2 insufflation. Patients were clinically assessed using the Lysholm, IKDC and KOOS scores. Radiological assessment used the MOCART score.


We describe a novel single stage arthroscopic repair procedure for articular cartilage defect in the knee. The aim of the study was to evaluate the clinical and radiological outcomes at two years.

The pre-clinical study involved two groups of New Zealand rabbits, treated with microfracture alone and microfracture combined with fibrin gel and concentrated bone marrow aspirate cells (BMAC) application. New cartilage from both groups was studied with histological staining, immunohistochemistry and electron microscopy. The fibrin gel-BMAC group scored better than the microfracture group on all counts.

This is a prospective study of 30 patients with symptomatic ICRS grade III/IV chondral defects, ranging from 2–8 cm2, which were assessed clinically and radiologically. The surgical procedure involved debridement of the lesion, microfracture and arthroscopic application of concentrated BMAC with fibrin gel under CO2 insufflation. Patients underwent morphological MRI, quantitative T2*-mapping and d-GEMRIC scan. Clinical assessment was carried out using the Lysholm, IKDC and KOOS scores while radiological assessment used the MOCART score.

At 2 year follow-up, Lysholm score was 80.1, as compared to 50.8 pre-operatively (p < 0.05). KOOS (symptomatic) was 92.1, as compared to 65.7 pre-operatively. IKDC (subjective) was 83, up from 39 preoperatively. The mean T2* relaxation-times for the repair tissue and native cartilage were 29.1 and 29.9 respectively. Average MOCART score for all lesions was 72.

Our technique shows encouraging clinical and radiological results. The morphological MRI shows good cartilage defect filling and the biochemical MRI (T2*-mapping) suggests hyaline like repair tissue.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 10 - 10
1 Jul 2014
Kim S Hong J Yoon H Kwon B Lee I Kim H
Full Access

Summary Statement

Obovatol inhibits receptor activator of nuclear factor kappa B ligand (RANKL)-induced osteoclastogenesis and prevents inflammatory bone loss in mice

Introduction

Adult skeletal mass and integrity are maintained by balancing osteoclast-mediated bone resorption and osteoblast-induced bone formation during bone remodeling. Abnormal increases in osteoclastic bone resorption can lead to excessive bone destruction as observed in osteoporosis, rheumatoid arthritis, and metastatic cancers Therefore, Modulation of osteoclast formation and function is a promising strategy for the treatment of bone-destructive diseases. To search for compounds that inhibit osteoclast formation, we tested the effect of obovatol, a natural product isolated from the medicinal plant Magnolia obovata, on osteoclastogenesis and inflammatory bone loss.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 264 - 264
1 Dec 2013
Nam KW Choi S Nam U Seo K Kim S Kim HJ
Full Access

Introduction:

Whole blood metal ion level and clinical outcomes of ceramic-on-metal bearing were comparable to ceramic-on-ceramic THA in this prospective randomized controlled trial.

Methods:

We randomized 150 consecutive THA cases at one institution into two groups: Group I and Group II. Group I, 75 cases, received a THA using ceramic-on-metal couplings and Group II, 75 cases, received ceramic-on-ceramic bearing THA. The implant differed only in the bearing surfaces used. We compared the serum levels of cobalt (Co) and chromium (Cr) and functional outcome scores preoperatively, and at 2, 6, and 12 months postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 377 - 377
1 Dec 2013
Ko KR Lee KH Kim S Lim S Moon Y
Full Access

Introduction:

The robot-assisted cementless total hip arthroplasty has theoretical advantages of providing better fit and mechanical stability of the stem. However, no previous study has been reported on a short stem implantation using surgical robot. We compared early clinical and radiographic results between robotic milling and manual rasping in short stem total hip arthroplasty.

Materials & Methods:

We designed a prospective randomized controlled trial to determine whether robot-assisted short stem total hip arthroplasty improves the implant position represented by stem alignment, leg length equality, and reduces the intraoperative and early postoperative complications. A total of 40 patients were enrolled with informed consents and randomly assigned to robotic milling group (20 hips) and manual rasping group (20 hips) by means of a computer-generated random number table. There were no statistically significant differences in the demographics of the patients between the two groups


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 399 - 399
1 Dec 2013
Lim S Lee KH Ko KR Kim S Moon Y Park Y
Full Access

Introduction:

Ceramic head with titanium-alloy sleeve offers a modular ceramic head solution for the damaged taper in revision total hip arthroplasty (THA). It can also be used in primary THA to reduce the risk of ceramic head fracture. The purpose of the present study was to report the intermediate-term outcomes of primary ceramic-on-ceramic THA with use of ceramic head with titanium-alloy sleeve.

Materials & Methods:

We evaluated 244 patients (271 hips) who had undergone primary ceramic-on-ceramic THA with use of BIOLOX® forte 32 mm ceramic head with titanium-alloy sleeve between November 2005 and August 2009. There were 158 males (175 hips) and 86 female (96 hips) patients with a mean age of 55.5 years. Clinical and radiographic evaluation was performed at a mean of 4.6 years (range, 2–7 years) postoperatively.