header advert
Results 21 - 40 of 75
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 105 - 105
1 May 2016
Kim J Park B Cho H
Full Access

Purpose

To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis.

Materials and Methods

From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 79 - 79
1 May 2016
Cho H Park B Kim J
Full Access

Purpose

To perform comparative analysis between the results of internal fixation using proximal femoral nail system and bipolar hemiarthroplasty in pantrochanteric hip fracture in elderly patients.

Materials and Methods

From January 2006 to February 2012, we reviewed 43 patients, who were treated surgically for pantrochanterichip fractures, with a minimum of 2 years follow up. The patient's age was older than 70 year old. The patients were divided into three groups and evaluated, retrospectively. The fracture reduction were regarded as satisfactory in S-OR-IF group(17 cases) and unsatisfactory in US-OR-IF group(9 cases) and the other group was treated with bipolar hemiarthroplasty (BHA group, 17 cases.)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 102 - 102
1 May 2016
Kim J Kim S
Full Access

Background

Theoretically, improved material properties of new alumina matrix composite (AMC) material, Delta ceramics, are expected to decrease concerns associated with pure alumina ceramics and allow manufacturing thinner liners and consequent larger heads. However, limited short-term clinical results are available and mid-term results of these effects are unclear.

Questions/Purposes

(1) Does AMC material decrease the rate of ceramic fracture and noise, concerns of previous-generation ceramics, following change of material properties? (2) Does the possible use of larger heads consequent to manufacturing thinner liners decrease dislocation rate and affect inguinal pain? (3) Do any other complications associated with the use of AMC ceramics occur?


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 96 - 96
1 May 2016
Kim K Lee S Kim J Shin W
Full Access

Background

In this study, we investigated the long-term clinical results and survivorship of minimally invasive unicompartmental knee arthroplasty (UKA) by collecting cases that have been implanted for >10 years ago.

Methods

Medial UKA on 180 cases in 142 patients was performed over a period of 1 year after the first introduction of minimally invasive UKA from January 2002 to December 2002. Among these, 166 cases in 128 patients who underwent Oxford phase 3 medial UKA using the minimally invasive surgery, with the exclusion of 14 cases including 10 cases of follow-up loss and 4 cases of death, were selected as the subject. The mean age of the patients at the time of surgery was 61 years, and the duration of the follow-up was minimum 10 years. All the preoperative diagnosis was osteoarthritis of the knee joint. Clinical and radiographic assessments were measured by the Knee Society clinical rating system, and the survival analysis was confirmed by the Kaplan–Meier method with 95% confidence interval (CI).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 97 - 97
1 May 2016
Kim K Lee S Kim J Ko D
Full Access

Purpose

To identify the modes of failure after total knee arthroplasty (TKA) in patients ≤ 55 years of age and to compare with those ≥ 56 years of age in patients who underwent revision TKA.

Materials and Methods

We retrospectively reviewed 256 revision TKAs among patients who underwent TKA for knee osteoarthritis between January 1992 and December 2012. The causes of TKA failure were analyzed and compared between those ≤ 55 years of age and those ≥ 56 years of age. The age at the time of primary surgery was ≤ 55 years in 30 patients (31 knees) and ≥ 56 years in 210 patients (225 knees).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 99 - 99
1 May 2016
Kim J Yoo O Seo J Jang Y Kim J Sun D Kim Y
Full Access

Introduction

A stem extension improves fixation stability of a tibial component. We need caution not to contact the tibial cortex with an offset adaptor. A symmetric tibial stem design often requires the component's re-positioning with negative effects. Therefore, the objective of this study was to validate clinical efficacy of a tibial baseplate with asymmetric stemmed position (TB-ASP) using aligning outlier rate. We hypothesized that TB-ASP design will be better aligned without unessential offset adaptor than a tibial baseplate with symmetric stemmed position (TB-SSP).

Methods

TB-ASP was designed based on the anthropometric standard model (58 female cadavers, 54.7±11.4 years)(Figure 1.). To validate the stem position, 3D bone models of 20 OA patients (71.8±7.2 years) was reconstructed. All virtual surgery has done by one surgeon with consistent surgical procedure for the analysis criteria.

An analysis of TB-ASP's aligning outlier was proceeded by following steps; 1) aligning tibial baseplate to the line from medial 1/3 tuberosity to the center of PCL, 2) selecting tibial baseplate's size for maximal bone coverage without problematic overhang, 3) trying to displace tibial baseplate and stem extension(120mm long) not to contact tibial cortex. A case invading tibial cortex was considered to be an outlier. The ratio using offset adaptor was compared to those of TB-SSP. Statistical analysis was performed using paired t-test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 2 - 2
1 May 2016
Lim Y Kwon S Sun D Kim S Kim J Choi S Kim Y
Full Access

Introduction

3-D Printing with direct metal tooling (DMT) technology was innovatively introduced in the field of surface treatment of prosthesis to improve, moreover to overcome the problems of plasma spray, hopefully resulting in opening the possibility of another page of coating technology. We presumed such modification on the surface of Co-Cr alloy by DMT would improve the ability of Co-Cr alloys to osseointegrate.

Method

We compared the in vitro and in vivo ability of cells to adhere to DMT coated Co-Cr alloy to that of two different types of surface modifications: machined and plasma spray(TPS). We performed energy-dispersive x-ray spectroscopy and scanned electron microscopy investigations to assess the structure and morphology of the surfaces. Biologic and morphologic responses to osteoblast cell lines of human were then examined by measuring cell proliferation, cell differentiation (alkaline phosphatase activity), and avb3 integrin. The cell proliferation rate, alkaline phosphatase activity, and cell adhesion in the MAO group increased in comparison to those in the machined and grit-blasted groups.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 130 - 130
1 May 2016
Kweon S Kim T Kim J Jeong K
Full Access

Purpose

The purpose of this study is to evaluate the clinical outcomes and and radiological findings of primary total hip arthroplasty(THA) performed by using cemented polished femoral stem.

Materials and Methods

We retrospectively reviewed 91 hips (84 patients) that had undergone primary THA with cemented polished femoral stem after follow-up more than 10 years. The mean age at surgery was 57 years old (47 to 75). Mean follow up period was 12. 8 years(10.1 to 14). Clinical evaluation was performed using Harris hip score. The radiographic evaluation was performed in terms of the cementing technique, including of subsidence within the cement mantle, radiolucent lines at the cement-bone or cement-stem interface, cortical hypertrophy, and calcar resorption.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 77 - 77
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

To evaluate the effectiveness of post-operative pain management using the intra-operative peri-articular injection(PAI) and/or electromyography (EMG)-guided preoperative femoral nerve block (FNB) in total knee arthroplasty(TKA).

Materials and Methods

From March 2013 to February 2014, 90 knees which underwent primary TKA by one surgeon were included in our study. The patients were classified into three groups; a single injection FNB with an EMG guide (Group I, 30 knees), intra-operative PAI (Group II, 30 knees) and both FNB and PAI (Group III, 30 knees). Pain at rest and moving was evaluated by Visual Analogue Scale (VAS) at postoperative 0, 4, 8, 24 and 48 hours. Postoperative range of motion, time to walking, total blood loss, amount of opioid consumption and complications were compared in each group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 148 - 148
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

To measure the vitamin D level of the patients who received total knee arthroplasty (TKA) and evaluate the effect of vitamin D level on the results of TKA.

Materials and Methods

From February 2012 to January 2013, 151 female patients (204 knees) who underwent primary TKA by one surgeon were included in our study. Preoperative vitamin D level was measured and analyzed the relationship between that and preoperative Visual Analogue Scale (VAS), and Knee Society Knee Score (KS) and Function Score (FS). Thirty-nine patients (39 knees) who received unilateral TKA and could be followed up more than 1 year after operation were evaluated for the relationship between vitamin D level and postoperative VAS, KS and FS, and Western Ontario and McMaster Universities Arthritis Index (WOMAC) score.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 79 - 79
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

The NexGen® legacy posterior stabilized (LPS)-Flex total knee system (Zimmer, Warsaw, IN) is designed to provide 150° of flexion following total knee arthroplasty (TKA). But, recent reports found a high incidence of loosening of the femoral component related to the deep flexion provided. We evaluated 9- to 12-year clinical and radiological follow-up results after NexGen® LPS-Flex TKA.

Materials and Methods

A retrospective evaluation was undertaken of 209 knees in 160 patients (21 males, 139 females) who were followed up for more than 9 years after Nexgen®LPS-Flex TKA. Evaluations included preoperative and postoperative range of motion(ROM), Knee Society(KS) knee score, function scores, tibiofemoral angle and assessment of postoperative complications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 104 - 104
1 Jan 2016
Cho S Youm Y Kim J
Full Access

Purpose

The purpose of this study was to compare the clinical and radiological results after total knee arthroplasty(TKA) with PCL sacrificing (PCS) Medial Pivot Knee (MPK) and PCL Substituting (PS) Nexgen® LPS.

Materials and Methods

One hundred twenty knees in 80 patients after TKA with PCS ADVANCE® MPK (Group I) and 116 knees in 85 patients with PS Nexgen® LPS (Group II) were retrospectively evaluated. All the patients were followed up for more than 6 years. The evaluations included preoperative and postoperative range of motion (ROM), tibiofemoral angle, Knee Society (KS) knee and function score, Hospital for Special Surgery (HSS) knee score, WOMAC score and postoperative complications.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 15 - 15
1 Apr 2013
Kim J Oh CW Oh JK Lee HJ Kyung HS
Full Access

Background

To establish relative fixation strengths of a single lateral locking plate, a double locking plate, and a tibial nail in treatment of proximal tibial extra-articular fractures.

Methods

Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included; lateral plating (LP) using a LCP-PLT (locking compression plate-proximal lateral tibia), double plating (DP) using a LCP-PLT and a LCP-MPT (locking compression plate-medial proximal tibia), and intramedullary nailing (IN) using an ETN (expert tibial nail). To simulate a comminuted fracture model, a gap osteotomy measuring 1 cm was cut 8 cm below the joint. For each tibia, a minimal preload of 100N was applied before loading to failure. A vertical load was applied at 25mm/min until tibia failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 63 - 63
1 Apr 2013
Kim J Oh C Oh JK Lee HJ
Full Access

Background

Although gradual bone transport may provide a large-diameter bone, complications are common with the long duration of external fixation. To reduce such complications, a new technique of bone transport with a locking plate has been done for tibial bone defect.

Methods

In 13 patients (mean age, 38.9 years) of chronic osteomyelitis or traumatic bone defect, segmental transport was done using external fixator with a locking plate. In surgical technique, a locking plate was fixed submuscularly, holding the proximal and distal segments. Then, the external fixator for transport was fixed without contact of the locking plate. After docking, 2 or 3 screws were fixed at the transported segment through the plate holes. At the same time, the external fixator was removed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 221 - 221
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To evaluate outcome after cementless bipolar hemiarthroplasties using a standard(tapered, rectangular) stem for the treatment of above type A2 fractures in elderly patients.

Material and methods

We reviewed the records of 37 patients who underwent bipolar hemiarthroplasty between February 2006 and Feburuary 2010 in our hospital who were followed for more than two years after surgery. The mean patient age was 73.5 years old (range 64∼88 years old). 16 patients were men, and 21 patients were women. We evaluated the results by analyzing operation time, amount of bleeding, recovery of walking ability, complications and radiologic findings.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 39 - 39
1 Mar 2013
Chung PH Kang S Kim J Kim YS Lee HM
Full Access

A seventy-five-year-old female patient presented with pain and deformity of her left leg of three days duration. Hybrid THRA has been done 11 years ago at her left hip for the treatment of osteoarthritis. Massive osteolysis and pathologic fracture were observed on plain radiograph (Fig. 1). Revision THRA using an allograft prosthesis composite (APC) was planned for solution of extensive bone loss of the proximal femur. Surgical exposure was performed through extended trochanteric osteotomy with the patient supine. Step-cut osteotomy was done at the remained proximal part of host femur to make match with the distal part of APC. Meticulous removal of granulation tissues and remaining cement was done. As Acetabular cup was stable, 60 mm sized high-walled polyethylene liner was exchanged. Calcar reconstruction prosthesis was cemented into a proximal femoral allograft measuring 15 cm and cement at the vicinity of the step-cut osteotomy was removed for later bony union at interface. After solid fixation of APC with cement, the distal half of APC was cemented with the host femur. Step-cut osteotomy was wired and autogenous bone grafts from the greater trochanter were added at the interface. Leg length and stability were rechecked using a standard necked 28 mm metal head and reduction was done stably. Greater trochanter was fixed over the trimmed proximal allograft with multiple wiring and paper-thin host femur was enveloped around the femoral allograft using absorbable sutures. Following insertion of the closed suction drainage drains, closure was done as routine fashion and healing of the wound was uneventful (Fig. 2). An abduction brace was applied post operatively for a period of four weeks. Crutch walking with partial weight bearing was started at four weeks and crutch protection was applied for a period of six months. Incorporation of allograft with the host bone was observed on two-year follow-up radiographs. At seven-year follow-up, the patient walks well with a mild limp, and Harris score is 90. We report on a seven-year follow-up case of revision THRA with APC with references (Fig. 3).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 220 - 220
1 Mar 2013
Cho H Kim J
Full Access

Purpose

To analyze the effectiveness of a vancomycin impregnated calcium sulfate cement bead insertion after debridement (of) an acute-immediate stage infected hip arthroplasty.

Materials and Methods

Between 2002 and 2008, 13 patients with documented acute-immediate stage infection of hip arthroplasty were reviewed and followed for at least two years postoperatively(average 4.3 years). The preoperative and postoperative clinical and radiologic findings and blood laboratory work were checked. All cases were performed through retention of the implant and massive debridement and saline irrigation. After that a vancomycin impregnated calcium sulfate cement beads was inserted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 35 - 35
1 Mar 2013
Cho H Kim J
Full Access

Recent reports about the excellent clinical results of unicondylar knee arthroplasty (UKA; also known as unicompartmental knee arthroplasty), by the minimally invasive approach, have encouraged the adoption of the surgical technique. However, friction between metallic prosthetic components resulting from polyethylene wear may result in the development of metallosis and the use of metal implants has become a huge issue in the worlds recently. Here, we report a case in which a patient underwent UKA and developed metallosis in soft tissues and bone adjacent to an implanted artificial joint three years postoperatively.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 222 - 222
1 Mar 2013
Kim J Chung PH Kang S Kim YS Lee HM
Full Access

The posterior-stabilized knee prosthesis is designed specifically to provide the posterior stability to a knee arthroplasty when PCL is deficient or has to be sacrificed. Posterior dislocation of such prosthesis is rare but dreaded complication. There are several causes of postoperative dislocation such as malposition of the prosthesis, preoperative valgus deformity, a defect of the extensor mechanism and overwidening of the flexion gap. Posterior-stabilized rotating-platform mobile-bearing knee implants have been widely used to further improve the postoperative range of motion by incorporation of the post and cam mechanism to improve the posterior roll back during flexion and to overcome the wear and osteolysis problems due to significant undersurface micromotion of posterior-stabilized fixed-bearing knees. But, spin-out or rotatory dislocation of the polyethylene insert can occurs as result of excessive rotation of the rotating platform accompanied by translation of the femur on the tibia after mobile-bearing total knee arthroplasty, but that is very rare. Here, authors describe an unusual case of acute 180° rotatory dislocation of the rotating platform after posterior dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty.

A 71-year-old male with knee osteoarthritis underwent a TKRA using posterior-stabilized mobile-bearing prosthesis. The posterior dislocation of the total knee arthroplasty occurred 5 weeks postoperatively(Fig. 1). We underwent closed reduction of posterior dislocated total knee arthroplasty resulting in a complete 180° rotatory dislocation of the rotating platform (Fig. 2). He was treated with open exploration and polyethylene exchange with a larger component.

This case illustrates that dislocation of a posterior-stabilized mobile-bearing total knee arthroplasty can occur with valgus laxity, cause 90° spin-out of the polyethylene insert and closed reduction attempts may contribute to complete 180° rotatory dislocation of the rotating platform. Special attention needs to be paid to both AP and lateral view to ensure that the platform is truly reduced and not just rotated 180° as was in this case.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 438 - 438
1 Sep 2012
Kim Y Kim J Joo J Park J
Full Access

Background

No study compared the clinical results of the posterior-stabilized mobile-bearing knee with those of nonposterior-stabilized mobile-bearing knee in the same patients. The purpose of this study was to examine whether the clinical and radiographic results, range of motion, patients satisfaction, and complication rates would be better in the knees with a posterior-stabilized mobile-bearing knee than in the knees with a nonposterior-stabilized mobile-bearing knee.

Methods

One hundred and fourteen patients (mean age, 67.9 years) received a nonposterior-stabilized mobile-bearing knee prosthesis in one knee and a posterior-stabilized mobile-bearing knee prosthesis in the contralateral knee. Seven patients were men, and 107 were women. At the time of each follow-up (mean, 7.3 years; range, seven to 7.6 years), the patients were assessed clinically and radiographically.