header advert
Results 21 - 40 of 129
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 15 - 15
1 Jun 2021
Anderson M Van Andel D Israelite C Nelson C
Full Access

Introduction

The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform.

Methods

This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and unicondylar joint arthroplasty. Participants in the treatment arm that underwent primary total or unicondylar knee arthroplasty and had at least 3 months of follow-up were included (n=367). Participants were provided the app with an associated smart watch for measuring several different health measures including daily step and flight counts. These measures were monitored preoperatively, and the following postoperative intervals were selected for review: 2–4 days, 1 month, 1.5 month, 3 months and 6 months. The data are presented as mean, standard deviation, median, and interquartile range (IQR). Signed rank tests were used to assess the difference in average of daily step counts over time. As not all patients reported having multiple stairs at home, a separate analysis was also performed on average flights of stairs (n=214). A sub-study was performed to evaluate patients who returned to preoperative levels at 1.5 months (step count) and 3 months (flight count) using an independent samples T test or Fisher's Exact test was to compare demographics between patients that returned to preoperative levels and those that did not.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 13 - 13
1 Jun 2021
Anderson M Van Andel D Foran J Mance I Arnold E
Full Access

Introduction

Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform.

Methods

A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88), unicondylar knee arthroplasty (UKA, n=28), and total hip arthroplasty (THA, n=82). Subjects were followed from 6 weeks preoperative to 24 weeks postoperative. The group was comprised of 117 females and 81 males with a mean age of 61.4 and BMI of 30.7. Signals were collected from the participants' smartphones. These signals were used to estimate gait quality according to walking speed, step length, and timing asymmetry. Post-operative measures were compared to preoperative baseline levels using a Signed-Rank test (p<0.05).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 56 - 56
1 Oct 2020
Lombardi AV Berend KR Huddleston J Crawford D Peters C VanAndel D Anderson M DeHaan A Southgate R Duwelius PJ
Full Access

Background

The purpose of this study is to evaluate the early outcomes with the use of a smartphone-based exercise and educational platform after primary total hip arthroplasty compared to a standard of care control group.

Methods

A multicenter prospective randomized control trial was conducted evaluating the use of the mymobility smartphone-based care platform for primary total hip arthroplasty (THA). Patients randomized to the control group (198 patients) received the respective institution's standard of care. Those randomized to mymobility treatment group (167 patients) were provided an Apple Watch and mymobility smartphone application. The application provides pre and postoperative educational content, video directed exercise programs as well as tracks the patient's activity. Patients in the treatment group were not initially prescribed physical therapy, but could be if their surgeon deemed it necessary. Early outcomes assessed included 90-day hip range of motion, HOOS JR scores, 30-day single leg stance (SLS) and time up and go (TUG) test.

We also evaluated PT utilization, THA complications associated with readmissions, ER visits not associated with readmissions, urgent care (non standard of care) visits, and physician office visits.

Outcome scores include HOOS-Jr, EQ-5D-5L, single stance (SLS), Timed up and go (TUG).

Satisfaction scores for the procedure and the mymobility study group were also recorded.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 55 - 55
1 Oct 2020
Mahan C Blackburn B Anderson LA Peters CL Pelt CE Gililland JM
Full Access

Introduction

Porous metaphyseal cones are increasingly used for fixation in revision total knee arthroplasty (RTKA). Both cemented shorter length stems and longer diaphyseal engaging stems are currently utilized with metaphyseal cones with no clear evidence of superiority. The purpose of this study was to evaluate our experience with 3D printed titanium metaphyseal cones with both short cemented and longer cementless stems from a clinical and radiographic perspective.

Methods

In total 136 3D printed titanium metaphyseal cones were implanted. The mean patient age was 63 and 48% were female. The mean BMI was 33 and the mean ASA class was 2.5. There were 42 femoral cones in which 28 cemented and 14 cementless stems were utilized. There were 94 tibial cones in which 67 cemented and 27 cementless stems were utilized. The choice for stem fixation was surgeon dependent and in general cones were utilized for AORI type 2 and 3 bone defects on the femur and tibia. The most common fixation scenario was short cemented stems on both the femur and tibia followed by cemented stem fixation on the tibia and cementless fixation on the femur. Clinical data such as revision, complication, and PRO was collected at last follow-up (minimum follow-up 1 year). Radiographic analysis included cone bony ingrowth and coronal and sagittal alignment on long-standing radiographs. Descriptive statistics were used to compare demographics between patients who had malalignment (HKA beyond +/− 3 degrees and flexion/extension beyond +/− 3 degrees). Adjusted logistic regression models were run to assess malalignment risk by stem type.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 16 - 16
1 Oct 2020
Anderson LA Wylie J Erickson JA Peters CL
Full Access

Introduction

Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular work such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose of this review was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary PAO cohort with no intra-articular work performed at the time of PAO.

Methods

From June 2012 to September 2019, 272 Rectus Sparing PAOs were performed and followed for a minimum of one year (mean 4.6 years). The average age was 24 (range 14–44) and 87% were female. The average BMI was 25 and average length of hospital stay was 2.9 days. Patients were evaluated at last follow-up with PROMIS PF-CAT, pain and mental health scores. Clinical records were reviewed for complications or subsequent surgery. Pre and post-operative radiographs were reviewed for change in the following acetabular parameters: LCEA, ACEA, AI, and the alpha-angle was obtained from preoperative radiographs. Patients were cross-referenced from the two largest hospital systems in our area to determine if subsequent HA was performed. Descriptive statistics and logistic regression were used to analyze risk factors for HA.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 72 - 72
1 Aug 2020
Gagne O Symes M Abbas KZ Penner M Wing K Younger A Syed K Lau J Veljkovic A Anderson L
Full Access

Patients' perspective and experience is heavily modulated by their understanding of their pre-operative disability along with their overall coping strategy and life philosophy. Given that evidence-based practice is relying on patient-reported outcomes more and more, the orthopaedic community must be diligent in differentiating patients that may have the same objective outcome but vary widely on a patient-reported subjective basis. In clinical practice, patient selection is often a sensitive, experience-based decision process that screens for catastrophization, recognizing that certain patients will not benefit from a simple surgery. It is well appreciated that patient's catastrophization can affect their subjective outcome but there is little reported literature on this abstract concept. The study set out to determine if post-operative outcomes correlated with pre-operative catastrophization scales.

This current study set out to look at a cohort of complex consecutive foot and ankle cases and describe the relationship between Patient Catastrophizing Score (PCS) and multiple functional outcomes that are used commonly in foot and ankle specifically (SF-12 & FAOS). The PCS has three subcategory rumination, helplessness and magnification. A single institution undertook recruitment in consecutive patients within three surgeon's practice. In the end, 46 patients were found to be eligible in the study with an average age of 54.72 ± 14.41 years-old, a majority female 30 / 46 (65.22%), a minority employed at the pre-operative visit 19/46 (41%) and with an average BMI of 26.2 ± 5.56.

We found that the mental component of the SF12 had a statistically significant negative effect with the rumination score (r=−1.03) (p = 0.01) and the helplessness score (r=−1.05) (0.001). There was no statistically significant effect for the physical component of the SF-12. Looking at the FAOS Pain component, it correlated was significantly with the PCS rumination (Multivariate : r= −7.6 (p=0.002) Univariate: r=−2 (0.03)) and helplessness (Multivariate : r=−6.73 (p=0.01) Univariate: r=−1.5 (p=0.03)). Otherwise the FAOS ADL component showed correlation as well with the PCS rumination (Multivariate: r=−4.67 (p=0.02) Univariate : r=−1.85 (p=0.01)), helplessness (Multivariate r=−5.89 (p = 0.01) Univariate r=−1.81 (p = 0.001)) and total score (Multivariate : r=3.74 (p=0.02) Univariate r=−0.75 (p=0.01)). The FAOS Quality of life component was statistically significant for the rumination score (Univariate r=−11.59) (p < 0.05) and the helplessness score (Univariate r=−9.65) (p = 0.002) also the PCS total (Univariate r=8.54) (p = 0.0003).

As layed out in our hypothesis, this study did show an association between an increase patient catastrophizing score pre-operatively and a worse outcome in the following scores: Mental component of SF12, FAOS Pain, FAOS ADL and FAOS Quality of life components. This is an association and no causality can be proven within the limits of this current pilot study, but remains alarming. In elective surgeries, catastrophization should be screened for using the PCS form and potentially modulated pre-operatively with the help of allied health therapist while a patient is on the waitlist.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 48 - 48
1 Oct 2019
Anderson L Erickson J Peters CL
Full Access

Introduction

Radiographic assessment of acetabular fragment positioning during periacetabular osteotomy (PAO) is of paramount importance. Plain radiographic examination is time and resource intensive. Fluoroscopic based assessment is increasingly utilized but can introduce distortion. Our purpose was to determine the correlation of intraoperative fluoroscopy-based measurements with a fluoroscopic tool that corrects for distortion with postoperative plain-film measurements.

Methods

We performed a prospective validation study on 32 PAO's (28 patients) performed by a single academic surgeon. Preoperative standing radiographs, intraoperative fluoroscopic images, and postoperative standing radiographs were evaluated with lateral center edge angle (LCEA), acetabular index (AI), posterior wall sign (PWS), and anterior center edge angle (ACEA). Intraoperative fluoroscopy was adjusted to account for pelvic inclination. The fluoroscopic GRID was utilized in all cases (Phantom MSK Hip Preservation, OrthoGrid LLC, Salt Lake City, UT). Intraoperative fluoroscopic measurements were compared to preoperative and postoperative standing radiographs at 6 weeks using linear regression applied in MINITAB.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 70 - 70
1 Oct 2018
Wodowski AJ Pelt CE Erickson J Anderson M Gililland J Peters CL Duensing I
Full Access

Introduction

Recent studies of novel healthcare episode payment models, such as the Bundled Payments for Care Improvement (BPCI) initiative, have demonstrated pathways for improving value. However, these models may not provide appropriate payments for patients with significant medical comorbidities or complications. The objective of this study was to identify risk factors for exceeding our institution's target payment, the so-called “bundle busters.”

Methods

After receiving an exemption from the Institutional Review Board, we queried our institutional data warehouse for all patients (n=412) that underwent total joint arthroplasty (TJA) of the hip (n=192), knee (n=207), or ankle (n=13), and qualified for our institution's bundled payments model during the study time period (July 2015 – May 2017). Patients with medical conditions that were not well controlled or were potentially optimizable were all sent for preoperative medical optimization prior to surgery. For each 90-day episode, patient characteristics, medical comorbidities, perioperative data, and payments from the Centers for Medicare and Medicaid Services (CMS) were obtained. Episodes where Medicare payments exceeded the target payment were considered “busters”. The busters were older, and had higher comorbidity scores (all, p<0.01). Variables were summarized using descriptive statistics and risk ratios were calculated using a modified Poisson regression analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 3 - 3
1 Oct 2018
Peters CL Anderson MB Erickson JA Anderson LA
Full Access

Introduction

The aim of this study was to compare patient reported outcomes, radiographic measurements, and survival free from total hip arthroplasty (THA) in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip (DDH).

Methods

We performed a retrospective cohort study on all patients (n=223, n=274 hips) who underwent a PAO procedure between May 1996 and May 2016, by a single surgeon at one academic center. Cases with a history of retroversion (n=64), Perthes (n=5), and those with <2 years of follow-up (n=63) were excluded. Patients were evaluated based on severity of dysplasia using the preoperative lateral center edge angle (LCEA): 18° – 25° was considered mild dysplasia (n=19), 10° – 17° moderate (n=62), and <10° severe (n=61). There was no difference in patient characteristics (age, sex, body mass index, or ASA score) between then cohorts (all, p>0.05). NIH PROMIS outcome measures included the physical function computerized adaptive test (PF CAT) and the Global 10 health assessment. Generalized estimating equations were used for all comparisons and missing data was imputed using the multivariate imputation by chained equations method. A Kaplan-Meier analysis was used to assess survival. Failure was defined as conversion to THA and follow-up was ended at time of failure or at the time of last follow-up. Mean follow-up was five years (1 – 19).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 60 - 60
1 Apr 2018
Anderson C Golladay G Roche M Gustke K Elson L
Full Access

Introduction & Aims

The traditional method of soft-tissue balancing during TKA is subjective in nature, and stiffness and instability are common indications for revision, suggesting that TKA balancing by subjective assessment is suboptimal. This study examines the intraoperative mediolateral loads measured with a nanosensor-enabled tibial insert trial and the sequential balancing steps used to achieve quantitative balance. Data obtained from a prospective multicenter study was assessed to determine the effect of targeted ligament release on intra-articular loading, and to understand which types of releases are necessary to achieve quantified ligament balance.

Methods

A group of 129 patients received sensor-assisted TKA, as part of a prospective multicenter study. Medial and lateral loading data were collected pre-release, during any sequential releases, and post-release. All data were collected at 10, 45, and 90 degrees during range of motion testing. Ligament release type, release technique type, and resultant loading were collected.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 18 - 18
1 Apr 2018
Preutenborbeck M Holub O Anderson J Jones A Hall R Williams S
Full Access

Introduction

Up to 60% of total hip arthroplasties (THA) in Asian populations arise from avascular necrosis (AVN), a bone disease that can lead to femoral head collapse. Current diagnostic methods to classify AVN have poor reproducibility and are not reliable in assessing the fracture risk. Femoral heads with an immediate fracture risk should be treated with a THA, conservative treatments are only successful in some cases and cause unnecessary patient suffering if used inappropriately. There is potential to improve the assessment of the fracture risk by using a combination of density-calibrated computed tomographic (QCT) imaging and engineering beam theory. The aim of this study was to validate the novel fracture prediction method against in-vitro compression tests on a series of six human femur specimens.

Methods

Six femoral heads from six subjects were tested, a subset (n=3) included a hole drilled into the subchondral area of the femoral head via the femoral neck (University of Leeds, ethical approval MEEC13-002). The simulated lesions provided a method to validate the fracture prediction model with respect of AVN.

The femoral heads were then modelled by a beam loaded with a single joint contact load. Material properties were assigned to the beam model from QCT-scans by using a density-modulus relationship. The maximum joint loading at which each bone cross-section was likely to fracture was calculated using a strain based failure criterion.

Based on the predicted fracture loads, all six femoral heads (validation set) were classified into two groups, high fracture risk and low fracture risk (Figure 1). Beam theory did not allow for an accurate fracture load to be found because of the geometry of the femoral head. Therefore the predicted fracture loads of each of the six femoral heads was compared to the mean fracture load from twelve previously analysed human femoral heads (reference set) without lesions.

The six cemented femurs were compression tested until failure. The subjects with a higher fracture risk were identified using both the experimental and beam tool outputs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 51 - 51
1 Apr 2018
Avadi MS Meng L Anderson J Fisher J Wang M Jin Z Qiu Y Williams S
Full Access

INTRODUCTION

Avascular necrosis (AVN) of the femoral head (FH) initiates from biological disruptions in the bone and may progress to mechanical failure of the hip. Mechanical and structural properties of AVN bone have not been widely reported, however such understanding is important when designing therapies for AVN. Brown et al.[1] assessed mechanical properties of different regions of AVN FH bone and reported 52% reduction in yield strength and 72% reduction in elastic modulus of necrotic regions when compared to non-necrotic bone. This study aimed to characterise structural and mechanical properties of FH bone with AVN and understand the relationship between lesion volume and associated mechanical properties.

METHODS

Twenty FH specimens from patients undergoing hip arthroplasty for AVN and six non-pathological cadaveric FH controls were collected. Samples were computed tomography scanned and images analysed for percentage lesion volume with respect to FH volume. Samples were further divided for structural and mechanical testing. The mechanical property group were further processed to remove 9mm cylindrical bone plugs from the load bearing and non-load-bearing regions of the FHs. FH and bone plug samples were tested in compression (1mm/min); elastic modulus and yield stress were calculated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2018
Makarewich CA Christensen M Anderson M Gililland J Pelt C Peters C
Full Access

Total hip arthroplasty (THA) in the young patient has been associated with higher rates of revision and perioperative complications. For clinicians and patients alike, there remains a desire to better characterize the durability of THA in young patients. We reviewed secondary data from our institutional database for all patients who underwent primary THA from January 2000 to May 2015. Patients were identified using ICD-9 procedure code 81.51. Our primary interest was the survival of implants in patients 30 years of age or younger (n=167) while using a contemporaneous cohort of patients age 60 and older as a control (n=1359). Failure was defined as revision THA for any reason. Cox regression with robust standard errors was used to calculate hazard ratios. A population-averaged Poisson regression analysis was used to compare complication rates.

The rate of all-cause revision THA was 2.4 times greater (95% CI 1.10 – 5.37, p=0.028) in young patients (7%, 12/167) undergoing primary or conversion to THA compared to their elderly counterparts (3.7%, 50/1,359). Survival at 10 years was 89% (95% CI 82 – 94) in the young cohort and 96% (94 – 97) in the elderly cohort. The primary reasons for revision in young that patients compared to their elderly counterparts included metal-on-metal implants (IRR 8.12, 95% CI 2.04 – 32.38, p=0.003).

These data demonstrate that patients 30 years of age and younger substantially benefit from THA but should be warned of higher risk of subsequent revision.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 29 - 29
1 Dec 2017
Anderson R Bates-Powell J Cole C Kulkarni S Moore E Norrish A Nickerson E
Full Access

Aim

This study aimed to evaluate the impact on length of hospital stay from dedicated infectious diseases input for orthopaedic infection patients compared to sporadic infection specialist input.

Method

We conducted an observational cohort study of 157 adults with orthopaedic infections at a teaching hospital in the UK. The orthopaedic infections included were: osteomyelitis, septic arthritis, infected metalwork and prosthetic joint infections, and adults were aged 18 years or more. Prior to August 2016, advice on orthopaedic infection patients was adhoc with input principally from the on-call infectious diseases registrar and phone calls to microbiology whereas after August 2016 these patients received regular input from dedicated infectious diseases doctor(s). The dedicated input involved bedside reviews, medical management, correct antimicrobial prescribing, managing adverse drug reactions, increased use of outpatient parenteral antimicrobial therapy (OPAT) services especially self-administration of intravenous antibiotics and shared decision-making for treatment failure, whilst remaining under orthopaedic team care. Orthopaedic patients operated on for management of their infection between 29/8/16 and 15/3/17 were prospectively identified and orthopaedic operation records were used to retrospectively identified patients between 29/8/15 and 15/3/16. The length of stay was compared between the 2 groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 119 - 119
1 Feb 2017
Anderson C Golladay G Roche M Gustke K Leone W
Full Access

Total knee arthroplasty (TKA) is currently one of the most common elective surgical procedures in the United States. The increase in the proportion of younger patients in receipt of surgery, in concert with a dramatic rise in the incidence of obesity, has contributed to the on-going, exponential increase in the number of arthroplasties performed annually. Despite materials advances for implants, the U.S. revision burden has remained static for the last decade. According to the 2013 CMS MEDPAR file the typical CMS reimbursement falls far short of costs incurred by the hospital, resulting in an average net loss of revenue of $9,539; and over 90% of hospitals lose money for every revision case performed. Today, approximately 5% of all primaries performed will result in an early revision (< 3 years). In order to understand ways with which to mitigate the incidence of early revision due to mechanical complications, a multicentric group of sensor-assisted patients was follow-up out to 3 years.

In this study, 278 sensor-assisted patients were followed out to 3 years. The intraoperative devices used in this study contain microsensors and a processing unit. Kinetic and center of load location data are projected, in real-time, to a screen. Because of the wireless nature of the intraoperative sensors, the patella can be reduced, and kinematic data can be evaluated through the range of motion. For each patient, the soft-tissue envelope was balanced to within a mediolateral differential of 15 lbf., through the ROM, as per the suggestion of previously reported literature. The average patient profile indicates: age = 69.7 years, BMI = 30.4, gender distribution = 36% male/64% female. Any adverse event within the 3-year follow-up interval was captured.

By 3 years, 1 patient in this population has required revision surgeon due to mechanical complicatons. Overall adverse events included: pain in hip (3), pain in contralateral knee (2), wound drainage (3), DVT (1), death (1), stiffness in operative knee (2), infection (3), global pain (2), back pain (2).

Based on the average reported number of early revisions that occur in the U.S. (5% of primaries), it was anticipated for this patient group to require approximately 13 revisions by the 3-year follow-up interval. Using 2013 CMS MEDPAR data, these 13 revisions would have resulted in $124,007 cost-to-hospital. However, only 1 revision (0.4%) was observered, therefore $114,468 in additional costs were spared for the aggregate of participating hospitals. This data suggests that the incorporation of kinetic sensors in TKA may assist the surgeon in achieving soft-tissue balance and thereby avoiding adverse mechanical complications that require surgical intervention.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 4 - 4
1 Feb 2017
Anderson C Gustke K Roche M Golladay G Jerry G Elson L
Full Access

Total knee arthroplasty (TKA) patients are consistently reported to be less satisfied than total hip arthroplasty (THA) patients. A patient's perception of success of his/her own total knee is dictated by their levels of post-operative pain and function, and many return to follow-up visits with inexplicable pain and stiffness that contradict favorable radiographic results. Several of these chief complaints that contribute to dissatisfaction are associated with soft-tissue imbalance. Therefore, in an effort to thoroughly understand the post-operative impact of soft-tissue balance on satisfaction, a multicenter study was conducted to evaluate the satisfaction outcomes of quantifiably balanced patients.

In this study, 102 sensor-assisted patients were followed out to 3 years. The intraoperative devices used in this study project kinetic loading (lbf.) and center of load location data, in real-time, to a screen. Because of the wireless nature of the intraoperative sensors, the patella can be reduced, and kinematic data can be evaluated through the range of motion. The target balance window that was used in this study has been previously reported in literature and includes: 1) a mediolateral differential of 15 lbf., through the ROM, and 2) Sagittal plane stability as determined by a posterior drawer analysis. A robust, face-validated satisfaction survey was administered at 3-year follow-up and included 7 questions with answers on a 5-point Likert scale.

At 3 years, post-operatively, 97.2% of this patient group reported being “satisfied” to “very satisfied” with their procedure, in comparison to the 81% average TKA satisfaction reported in literature (df = 11). The comparative literature included annual satisfaction intervals from 1 to 5 years (n = 33,775) which is comparable to the interval reported in this patient group. The sensor-assisted patient group exhibited a 16% increase in the proportion of satisfaction over what is currently reported in the comparative literature (p = 0.001).

Despite the success rate of TKA, unfavorable patient-reported satisfaction continues to present a problem for operative recipients and surgeons. Because satisfaction is dependent upon several variables – including pain, function, and activity levels – the satisfaction survey used in this study represents a more accurate account of patient perception than many traditional surveys. It was shown that sensor-balanced TKA patients exhibited a 16% increase in the proportion of those reporting being “satisfied” to “very satisfied”, over the average satisfaction reported in literature. Allowing the surgeon to quantitatively balance the soft-tissue envelope, dynamically, has continued to a significant decrease in the proportion of dissatisfaction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 49 - 49
1 Nov 2016
Sermer C Kandel R Hurtig M Anderson J Theodoropoulos J
Full Access

Osteoarthritis (OA) is a debilitating disease characterised by degradation of articular cartilage and subchondral bone remodeling. Current therapies for early or midstage disease do not regenerate articular cartilage, or fail to integrate the repair tissue with host tissue, and therefore there is great interest in developing biological approaches to cartilage repair. We have shown previously that platelet-rich plasma (PRP) can enhance cartilage tissue formation. PRP is obtained from a patient's own blood, and is an autologous source of many growth factors and other molecules which may aid in healing. This raised the question as to whether PRP could enhance cartilage integration. We hypothesise that PRP will enhance integration of bioengineered cartilage with native cartilage.

Chondrocytes were isolated from bovine metacarpal-phalangeal joints, seeded on a porous bone substitute (calcium polyphosphate) and grown in the presence of FBS to form an in vitro model of osteochondral-like tissue. After 7 days, the biphasic constructs were soaked in PRP for 30 minutes prior to implantation into the core of a ring-shaped biphasic explant of native bovine cartilage and bone. Controls were not soaked in PRP. The resulting implant-explant construct was cultured in a stirring bioreactor in serum free conditions for 2 weeks. The integration zone was visualised histologically. A push-out test was performed to assess the strength of integration. Matrix accumulation at the zone of integration was assessed biochemically and the gene expression of the cells in this region was assessed by RT-PCR. Significance (p<0.05) was assessed by a student's t-test or one-way ANOVA with tukey's post hoc.

PRP soaked bioengineered implants, integrated with the host tissue in 73% of samples, whereas control bioengineered implants only integrated in 19% of samples based on macroscopic evaluation (p<0.05). The integration strength, as determined by the normalised maximum force to failure, was significantly increased in the PRP soaked implant group compared to controls (219 +/− 35.4 kPa and 72.0 +/− 28.5 kPa, respectively, p<0.05). This correlated with an increase in glycosaminoglycan and collagen accumulation in the region of integration in the PRP treated implant group, compared to untreated controls after 2 weeks (p<0.05). Immunohistochemical studies revealed that the integration zone was rich in collagen type II and aggrecan. The cells at the zone of integration in the PRP soaked group had a 2.5 fold increase in aggrecan gene expression (p=0.05) and a 3.5 fold increase in matrix metalloproteinase 13 expression (p<0.05) compared to controls.

PRP soaked bio-engineered cartilage implants showed improved integration with native cartilage compared to non-treated implants, perhaps due to the increased matrix accumulation and remodeling at the interface. Further evaluation is required to determine if PRP improves integration in vivo.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 22 - 22
1 Oct 2016
Ramakrishnan P Maclean M MacGregor SJ Anderson J Grant MH
Full Access

Healthcare associated infections (HAI) pose a major threat to patients admitted to hospitals, and infection rates following orthopaedic arthroplasty surgery are as high as 4%, while the infection rates are even higher after revision surgery. 405 nm High-Intensity Narrow Spectrum (HINS) light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in orthopaedic surgery.

Cultured rat osteoblasts were exposed to 405 nm light to investigate if bactericidal doses of light could be used safely in the presence of mammalian cells. Cell viability was measured by MTT reduction and microscopy techniques, function by alkaline phosphatase activity, and proliferation by the BrdU assay. Exposures of up to a dose of 36 J/cm2 had no significant effect on osteoblast cell viability, whilst exposure of a variety of clinically relevant bacteria, to 36 J/cm2 resulted in up to 100% kill. Exposure to a higher dose of 54 J/cm2 significantly affected the osteoblast cell viability, indicating dose dependency.

Work also demonstrated that 405 nm light exposure induces reactive oxygen species (ROS) production in both mammalian and bacterial cells, as shown by fluorescence generated from 6-carboxy-2′,7′-dichlorodihydrofluorescein diacetate dye. The mammalian cells were significantly protected from dying at 54 J/cm2 by catalase, which detoxifies H2O2. Bacterial cells were significantly protected by sodium pyruvate (H2O2 scavenger) and by a combination of free radical scavengers (sodium pyruvate, dimethyl thiourea (·OH scavenger), catalase) at 162 and 324 J/cm2. Thus the cytotoxic mechanism of 405 nm light in mammalian cells and bacteria is likely oxidative stress involving predominantly H2O2 generation, with other ROS contributing to the damage.

Additional work describing the potential for incorporation of this antimicrobial light within operating theatre lighting systems will also be discussed, and this, coupled with the cell viability and cytotoxicity results, suggests that 405 nm light could have great potential for continual patient safe decontamination during orthopaedic replacement surgeries and thereby reduce the incidence of infections.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 35 - 35
1 Oct 2016
Asif I Williams S Fisher J Al-Hajjar M Anderson J Tipper J
Full Access

Wear particles produced by alumina ceramic-on-ceramic (CoC) bearings cause a minimal immunological response with low cytotoxicity and inflammatory potential1, 2. However, more comprehensive immunological studies are yet to be completed for the composite CoC (zirconia-toughened, platelet reinforced alumina) hip replacements due to difficulties in isolating the very low volume of clinically relevant wear debris generated by such materials in vitro. The aim of this study was to compare the cytotoxic effects of clinically relevant cobalt chromium (CoCr) nano-particles with commercial composite ceramic particles.

Composite ceramic particles (commercial BIOLOX® delta powder) were obtained from CeramTec, Germany and clinically relevant CoCr wear particles were generated using a six station pin-on-plate wear simulator. L929 fibroblast cells were cultured with 50µm3 of CoCr wear debris or composite ceramic particles at low to high volumes ranging from 500µm3–0.5µm3 per cell and the cyctotoxic effects of the particles were assessed over a period of 6 days using the ATP-Lite™ cell viability assay.

The composite ceramic particles were bimodal in size (0.1–2µm & 30–100nm) and showed mild cytotoxic effects when compared with equivalent particle volumes (50µm3) of clinically relevant CoCr nano-particles (10–120nm). The CoCr nano-particles had significant cytotoxic effects from day 1, whereas the composite ceramic particles only showed cytotoxic effects at particle concentrations of 50 and 500µm3 after 6 days. The increased cytotoxicity of the clinically relevant CoCr nano-particles may have been attributed to the release of Co and Cr ions.

This study demonstrated the potential cytotoxic effects of model ceramic particles at very high volume concentrations, but it is unlikely that such high particle volumes will be experienced routinely in vivo in such low wearing bearing materials. Future work will investigate the longer-term effects on genotoxicity and oxidative stress of low volumes of clinically-relevant generated BIOLOX® delta ceramic wear particles.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 3 - 3
1 May 2016
Elson L Leone W Roche M Anderson C
Full Access

Introduction

The rate of technological innovation in procedural total knee arthroplasty has left little time for critical evaluation of a new technology before the adoption of even newer modalities. With more drastic financial restrictions being placed on operating room spending, orthopaedic surgeons are now required to provide excellent results on a budget.

It is integral that both clinical efficacy and cost-effectiveness of these intraoperative technologies be fully understood in order to provide patients with effectual, economically conscious care. The purpose of this qualitative analysis of literature was to evaluate clinical and economic efficacy of the three most prominent technologies currently used in TKA: computer navigation, patient-specific instrumentation, and kinetic sensors.

Methods

Three hundred and ninety one publications were collected; 100 were included in final qualitative analysis. Criteria for inclusion in the analysis was defined only insofar as that each piece assessed one of the above listed aspects of the three technologies Literature included in the final evaluation contained background information on each respective technology, clinical outcomes, revision rates, and/or cost analyses. All comparisons were conducted in a strictly qualitative manner, and no attempts were made to conduct interstudy statistical analyses due to the high level of variability in methodology and data collected.