Aims. Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free
Aims. The objective of this study was to compare simulated
Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee
Aims. In computer simulations, the shape of the
Aims. Pelvic tilt (PT) can significantly change the functional orientation of the acetabular component and may differ markedly between patients undergoing total hip arthroplasty (THA). Patients with stiff spines who have little change in PT are considered at high risk for instability following THA. Femoral component position also contributes to the limits of impingement-free
Aims. The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice. Methods. A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological
Aims. The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional
Cadaveric models of the shoulder evaluate discrete motion segments
using the glenohumeral joint in isolation over a defined trajectory.
The aim of this study was to design, manufacture and validate a
robotic system to accurately create three-dimensional movement of
the upper body and capture it using high-speed motion cameras. In particular, we intended to use the robotic system to simulate
the normal throwing motion in an intact cadaver. The robotic system
consists of a lower frame (to move the torso) and an upper frame
(to move an arm) using seven actuators. The actuators accurately
reproduced planned trajectories. The marker setup used for motion
capture was able to determine the six degrees of freedom of all
involved joints during the planned motion of the end effector.Objectives
Methods
Aims. Isolated fractures of the ulnar diaphysis are uncommon, occurring at a rate of 0.02 to 0.04 per 1,000 cases. Despite their infrequency, these fractures commonly give rise to complications, such as nonunion, limited forearm pronation and supination, restricted elbow
Aims. The primary aim of this study is to quantify and compare outcomes following a dorsally displaced fracture of the distal radius in elderly patients (aged ≥ 65 years) who are managed conservatively versus with surgical fixation (open reduction and internal fixation). Secondary aims are to assess and compare upper limb-specific function, health-related quality of life, wrist pain, complications, grip strength,
Aims. There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA). Methods. We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain,
Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow
Aims. The ulna is an extremely rare location for primary bone tumours of the elbow in paediatrics. Although several reconstruction options are available, the optimal reconstruction method is still unknown due to the rarity of proximal ulna tumours. In this study, we report the outcomes of osteoarticular ulna allograft for the reconstruction of proximal ulna tumours. Methods. Medical profiles of 13 patients, who between March 2004 and November 2021 underwent osteoarticular ulna allograft reconstruction after the resection of the proximal ulna tumour, were retrospectively reviewed. The outcomes were measured clinically by the assessment of elbow
Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale,
Aims. With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting. Methods. MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used. Results. A total of nine studies were included, made up of four randomized controlled trials (domain 1) and five cohort studies (domain 2). PROMs and knee function specific scores developed for reporting TKA were unable to detect any difference between PFA and TKA. There was no significant difference in complications between PFA and TKA. PFAs were found to have a better postoperative
Aims. To explore the clinical efficacy of using two different types of articulating spacers in two-stage revision for chronic knee periprosthetic joint infection (kPJI). Methods. A retrospective cohort study of 50 chronic kPJI patients treated with two types of articulating spacers between January 2014 and March 2022 was conducted. The clinical outcomes and functional status of the different articulating spacers were compared. Overall, 17 patients were treated with prosthetic spacers (prosthetic group (PG)), and 33 patients were treated with cement spacers (cement group (CG)). The CG had a longer mean follow-up period (46.67 months (SD 26.61)) than the PG (24.82 months (SD 16.46); p = 0.001). Results. Infection was eradicated in 45 patients overall (90%). The PG had a better knee
Aims. The optimal management of posterior malleolar ankle fractures, a prevalent type of ankle trauma, is essential for improved prognosis. However, there remains a debate over the most effective surgical approach, particularly between screw and plate fixation methods. This study aims to investigate the differences in outcomes associated with these fixation techniques. Methods. We conducted a comprehensive review of clinical trials comparing anteroposterior (A-P) screws, posteroanterior (P-A) screws, and plate fixation. Two investigators validated the data sourced from multiple databases (MEDLINE, EMBASE, and Web of Science). Following PRISMA guidelines, we carried out a network meta-analysis (NMA) using visual analogue scale and American Orthopaedic Foot and Ankle Score (AOFAS) as primary outcomes. Secondary outcomes included
Aims. The aim of this study was to develop a core outcome set of what to measure in all future clinical research on hand fractures and joint injuries in adults. Methods. Phase 1 consisted of steps to identify potential outcome domains through systematic review of published studies, and exploration of the patient perspective through qualitative research, consisting of 25 semi-structured interviews and five focus groups. Phase 2 involved key stakeholder groups (patients, hand surgeons, and hand therapists) prioritizing the outcome domains via a three-round international Delphi survey, with a final consensus meeting to agree the final core outcome set. Results. The systematic review of 160 studies identified 74 outcome domains based on the World Health Organization International Classification of Functioning, Disability, and Health. Overall, 35 domains were generated through thematic analysis of the patient interviews and focus groups. The domains from these elements were synthesised to develop 37 outcome domains as the basis of the Delphi survey, with a further four generated from participant suggestions in Round 1. The Delphi survey identified 20 outcome domains as ‘very important’ for the core outcome set. At the consensus meeting, 27 participants from key stakeholder groups selected seven outcomes for the core outcome set: pain/discomfort with activity, pain/discomfort with rest, fine hand use/dexterity, self-hygiene/personal care, return to usual work/job,
Aims. The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. Methods. A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and
Aims. Frozen shoulder is a common, painful condition that results in impairment of function. Corticosteroid injections are commonly used for frozen shoulder and can be given as glenohumeral joint (GHJ) injection or suprascapular nerve block (SSNB). Both injection types have been shown to significantly improve shoulder pain and