This study aimed to evaluate whether an enhanced recovery protocol (ERP) for arthroplasty established during the COVID-19 pandemic at a safety net hospital can be associated with a decrease in hospital length of stay (LOS) and an increase in same-day discharges (SDDs) without increasing acute adverse events. A retrospective review of 124 consecutive primary arthroplasty procedures performed after resuming elective procedures on 11 May 2020 were compared to the previous 124 consecutive patients treated prior to 17 March 2020, at a single urban safety net hospital. Revision arthroplasty and patients with < 90-day follow-up were excluded. The primary outcome measures were hospital LOS and the number of SDDs. Secondary outcome measures included 90-day complications, 90-day readmissions, and 30day emergency department (ED) visits.Aims
Methods
In 2020, the COVID-19 pandemic meant that proceeding with elective surgery was restricted to minimize exposure on wards. In order to maintain throughput of elective cases, our hospital (St Michaels Hospital, Toronto, Canada) was forced to convert as many cases as possible to same-day procedures rather than overnight admission. In this retrospective analysis, we review the cases performed as same-day arthroplasty surgeries compared to the same period in the previous 12 months. We conducted a retrospective analysis of patients undergoing total hip and knee arthroplasties over a three-month period between October and December in 2019, and again in 2020, in the middle of the COVID-19 pandemic. Patient demographics, number of outpatient primary arthroplasty cases, length of stay for admissions, 30-day readmission, and complications were collated.Aims
Methods
Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV.Objectives
Materials and Methods