Converting UKA to TKA can be difficult, and specialised techniques are needed. Issues include bone loss, joint line approximation, sizing, and rotation. Determining the complexity of conversion pre-operatively helps predict the need for augmentation, grafting, stems, or constraint.
In a 2009 study from our center, 50 UKA revised to TKA (1997–2007) were reviewed: 9 implants (18%) were modular fixed-bearing, 4 (8%) were metal-backed nonmodular fixed-bearing, 8 (16%) were resurfacing onlay, 10 (20%) were all-polyethylene step-cut, and 19 (38%) were mobile bearing designs; 5 knees (10%) failed due to infection, 5 (10%) due to wear and/or instability, 10 (20%) for pain or progression of arthritis, 8 (16%) for tibial fracture or severe subsidence, and 22 (44%) due to loosening of either one or both components. Insert thickness was no different between implants (P=0.23) or failure modes (P=0.27). Stemmed component use was most frequent with nonmodular components (50%), all-polyethylene step-cut implants (44%), and modular fixed-bearing implants (33%; P=0.40). Stem use was highest in tibial fracture (86%; P=0.002). Augment use was highest among all-polyethylene step-cut implants (all-polyethylene, 56%; metal-backed, 50%; modular fixed-bearing, 33%; P=0.01). Augmentation use was highest in fracture (86%) and infection (67%), with a significant difference noted between failure modes (P=0.003). Failure of nonmodular all-polyethylene step-cut devices was more complex than resurfacing or mobile bearing. Failure mode was predictive of complexity. Reestablishing the joint line, ligamentous balance, and durable fixation are critical to assuring a primary outcome.
In a 2013 multicenter study of 3 institutions including ours, a total of 175 revisions of medial UKA in 168 patients (81 males, 87 females; average age of 66 years) performed from 1995 to 2009 with a minimum of 2-year clinical follow-up were reviewed. The average time from UKA to revision TKA was 71.5 months (range: 2 months to 262 months). The four most common reasons for failure of the UKA were femoral or tibial loosening (55%), progressive arthritis of the lateral or patellofemoral joints (34%), polyethylene failure (4%) and infection (3%). Mean follow-up after revision was 75 months. Nine of 175 knees (4.5%) were subsequently revised at an average of 48 months (range 6 months to 123 months.) The rate of revision was 1.23 revisions per 100 observed component years. The average Knee Society pain and function score increased to 75 and 66, respectively. In the present series, the re-revision rate after revision TKA from UKA was 4.5 % at an average of 75 months or 1.2 revisions per 100 observed component years.
In a current study from our center, 174 patients (180 UKA) underwent revision procedures (1996–2017). Most prevalent indications for revision were aseptic loosening (45%) arthritic progression (17%) and tibial collapse (13%). At 4 years mean follow-up, 5 knees (2.8%) have required re-revision involving any part, which is similar to what we recently reported at 5.5 years in a group of patients who underwent primary TKA (6 of 189; 3.2%), and much lower than what we observed at 6.0 years in a recent report of patients who underwent aseptic revision TKA (35 of 278; 12.6%).
Compared to published individual institution and national registry data, re-revision of a failed UKA is equivalent to revision rates of primary TKA and substantially better than re-revision rates of revision TKA. These data should be used to counsel patients undergoing revision UKA to TKA.