Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

LIGAMENT BALANCING IN THE VALGUS KNEE

The Current Concepts in Joint Replacement (CCJR) Spring Meeting, Las Vegas, May 2017.



Abstract

Alignment of total joint replacement in the valgus knee can be done readily with intramedullary alignment and hand-held instruments. Intramedullary alignment instruments usually are used for the femoral resection. The distal femoral surfaces are resected at a valgus angle of 5 degrees. A medialised entry point is advised because the distal femur curves toward valgus in the valgus knee, and the distal surface of the medial femoral condyle is used as reference for distal femoral resection. In the valgus knee, the anteroposterior axis is especially important as a reliable landmark for rotational alignment of the femoral surface cuts because the posterior femoral condyles are in valgus malalignment, and are unreliable for alignment. Rotational alignment of the distal femoral cutting guide is adjusted to resect the anterior and posterior surfaces perpendicular to the anteroposterior axis of the femur. In the valgus knee this almost always results in much greater resection from the medial than from the lateral condyle. Intramedullary alignment instruments are used to resect the proximal tibial surface perpendicular to its long axis. Like the femoral resection, resection of the proximal tibial surface is based on the height of the intact medial bone surface.

After correction of the deformity, ligament adjustment is almost always necessary in the valgus knee. Stability is assessed first in flexion by holding the knee at 90 degrees and maximally internally rotating the extremity to stress the medial side of the knee, then maximally externally rotating the extremity to evaluate the lateral side of the knee. Medial opening greater than 4mm, and lateral opening greater than 5mm, is considered abnormally lax, and a very tight lateral side that does not open at all with varus stress is considered to be abnormally tight. Stability is assessed in full extension by applying varus and valgus stress to the knees. Medial opening greater than 2mm is considered to be abnormally lax, and a very tight lateral side that does not open at all with varus stress is considered to be too tight.

Release of tight structures should be done in a conservative manner. In some cases, direct release from bone attachment is best (popliteus tendon); in others, release with pie-crusting technique is safe and effective. In knees that are too tight laterally in flexion, but not in extension, the LCL is released in continuity with the periosteum and synovial attachments to the bone. When this lateral tightness is associated with internal rotational contracture, the popliteus tendon attachment to the femur is also released. The iliotibial band and lateral posterior capsule should not be released in this situation because they provide lateral stability only in extension.

The only structures that provide passive stability in flexion are the LCL and the popliteus tendon complex, so knees that are tight laterally in flexion and extension have popliteus tendon or LCL release (or both). Stability is tested after adjusting tibial thickness to restore ligament tightness on the lateral side of the knee. Additional releases are done only as necessary to achieve ligament balance. Any remaining lateral ligament tightness usually occurs in the extended position only, and is addressed by releasing the iliotibial band first, then the lateral posterior capsule, if needed. The iliotibial band is approached subcutaneously and released extrasynovially, leaving its proximal and distal ends attached to the synovial membrane. In knees initially too tight laterally in extension, but not in flexion, the LCL and popliteus tendon are left intact, and the iliotibial band is released. If this does not loosen the knee enough laterally, the lateral posterior capsule is released. The LCL and popliteus tendon rarely, if ever, are released in this type of knee.

Finally, the tibial component thickness is adjusted to achieve proper balance between the medial and lateral sides of the knee. Anteroposterior stability and femoral rollback are assessed, and posterior cruciate substitution is done, if necessary, to achieve acceptable posterior stability.