Abstract
Background
Total Shoulder Arthroplasty (TSA) has been shown to improve the function and pain of patients with severe degeneration. Recently, TSA has been of interest for younger patients with higher post-operative expectations; however, they are treated using traditional surgical approaches and techniques, which, although amenable to the elderly population, may not achieve acceptable results with this new demographic. Specifically, to achieve sufficient visualization, traditional TSA uses the highly invasive deltopectoral approach that detaches the subscapularis, which can significantly limit post-operative healing and function. To address these concerns, we have developed a novel surgical approach, and guidance and instrumentation system (for short-stemmed/stemless TSA) that minimize muscle disruption and aim to optimize implantation accuracy.
Development
Surgical Approach: A muscle splitting approach with a reduced incision size (∼6–8cm) was developed that markedly reduces muscle disruption, thus potentially improving healing and function. The split was placed between the infraspinatus and teres-minor (Fig.1) as this further reduces damage, provides an obvious dissection plane, and improves access to the retroverted articular surfaces. This approach, however, precludes the use of standard bone preparation methods/instruments that require clear visualization and en-face articular access. Therefore, a novel guidance technique and instrumentation paradigm was developed.
Minimally Invasive Surgical Guidance: 3D printed Patient Specific Guides (PSGs) have been developed for TSA; however, these are designed for traditional, highly invasive approaches providing unobstructed access to each articular surface separately. As the proposed approach does not offer this access, a novel PSG with two opposing contoured surfaces has been developed that can be inserted between the humeral and scapular articular surfaces and use the rotator cuff's passive tension to self-locate (Fig.2). During computer-aided pre-operative planning/PSG design, the two bones are placed into an optimized relative pose and the PSG is constructed between and around them. This ensures that when the physical PSG is inserted intra-operatively, the bones are locked into the preoperatively planned pose.
New Instrumentation Paradigm: With the constraints of this minimally invasive approach, a new paradigm for bone preparation/instrumentation was required which did not rely on en-face access. This new paradigm involves the ability to simultaneously create glenoid and humeral guide axes – the latter of which can guide humeral bone preparation and be a working channel for tools – by driving a short k-wire into the glenoid by passing through the humerus starting laterally (Fig.3). By preoperatively defining the pose produced by the inserted PSG as one that collinearly aligns the bones’ guide axes, the PSG and an attached c-arm drill guide facilitate this new lateral drilling technique. Subsequently, bone preparation is conducted using novel instruments (e.g. reamers and drills for creating holes radial to driver axis) powered using a trans-humeral driver and guided by the glenoid k-wire or humeral tunnel.
Conclusion
To meet the expectations of increasingly younger TSA patients, advancements in procedural invasiveness and implantation accuracy are needed. This need was addressed by developing a novel, fully integrated surgical approach, PSG system, and instrumentation paradigm, the initial in-vitro results of which have demonstrated acceptable accuracy while significantly reducing invasiveness.