OUTCOME OF PERIPROSTHETIC FEMORAL FRACTURE USING A TAPERED FLUTED MODULAR REVISION STEM: COMPARISON BETWEEN CEMENTED AND CEMENTLESS PRIMARY STEM

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 3.



Abstract

Purpose

The purpose of this study was to evaluate the results of modular revision stems, uncemented fluted, tapered to treat periprosthetic femoral (PFF) fracture; we specifically evaluated fracture union, implant stability, patient outcomes, and complications to compare the differences between cemented and cementless primary stem.

Materials and Methods

We retrospectively reviewed 56 cases of unstable periporsthetic femoral fracture (forty B2 and sixteen B3) treated with the uncemented fluted and tapered modular distal fixation stem with or with or without autogenous bone graft. Clinical outcomes were assessed with Harris Hip Score and WOMAC score. Radiologic evaluations were conducted using Beals and Tower's criteria. Any complication during the follow-up period was recorded.

Results

The average follow-up period was 52.1±32.7 months. The average Harris Hip Score was 72.4±19.1. All fractures were united, and a good consolidation was achieved in 47 cases. There was femoral stem subsidence in 3 cases less than 10 mm without an evidence of loosening both radiologically and clinically. The radiologic results using Beals and Towers’ criteria were excellent in 36 hips, good in 10 hips and poor in 10 hips. Radiologic bone union took longer time and statistically significant stem subsidence was observed in cemented primary stem compared to cementless primary stem (Fig1,2). At each follow-up examination the clinical score was significantly higher in patients with cementless primary stem.

Conclusion

Our results support the view that cement primary stem has less favorable result in terms of revision arthroplasty for periprosthetic femoral fractures.