Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

THE CEMENTED ALL-POLY TIBIA: AN AFFORDABLE CARE ACT SOLUTION – AFFIRMS

Current Concepts in Joint Replacement (CCJR) – Winter 2015 meeting (9–12 December).



Abstract

Total knee replacement (TKR) is one of the most successful procedures in orthopaedic surgery. Although originally limited to more elderly and less active individuals, the inclusion criteria for TKR have changed, with ever younger, more active and heavier patients receiving TKR. Currently, wear debris related osteolysis and associated prosthetic loosening are major modes of failure for TKR implants of all designs. Initially, tibial components were cemented all polyethylene monoblock constructs. Subsequent long-term follow-up studies of these implants have demonstrated excellent durability in survivorship studies out to twenty years. Aseptic loosening of the tibial component was one of the main causes of failure in these implants. Cemented metal-backed nonmodular tibial components were subsequently introduced to allow for improved tibial load distribution and to protect osteoporotic bone. Long-term studies have established that many one-piece nonmodular tibial components have maintained excellent durability. Eventually, modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80s mainly to facilitate screw fixation for cementless implants. These designs also provided intraoperative versatility by allowing interchange of various polyethylene thicknesses, and to also aid the addition of stems and wedges. Other advantages included the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. However, several studies have documented the high failure rate of isolated polyethylene exchange procedures, probably because technical problems related to the original components are left uncorrected. Since the late 1980s, the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of synovitis, progressive osteolysis, and severe polyethylene wear remain unclear, but there is no question that it was associated with the widespread use of both cementless and cemented modular tibial designs.

Mayo Data

The study population included 10,601 adult patients with 14,524 primary TKA procedures performed at our institution between 1/1/1988 and 12/31/2005. Mean age was 68.7 years and 55% were female. Overall revision rates and revisions for loosening, wear/osteolysis were compared across different designs. Over an average 9 year follow-up, a total of 865 revisions, including 252 tibia revisions were performed, corresponding to overall survival of 89% (Confidence intervals (CI): 88%, 90%) at 15 years. In comparison to metal modular designs, risk of tibial revision was significantly lower with all-poly tibias (HR 0.3, 95% CI: 0.2, 0.5). Overall, posterior cruciate-retaining designs performed better than the posterior-stabilised designs (p=0.002). With any revision as the endpoint, there were no significant differences across the 18 designs examined. Similarly, there were no significant differences across the 18 designs when we considered revisions for aseptic loosening, wear, and osteolysis. Among patient characteristics, male gender, younger age, and higher BMI were all significantly associated with higher risk of revisions (p<0.008).

Summary

Available data support the use of nonmodular tibial designs in TKA in order to prevent or reduce the chance of backside wear, third body particles from resulting metallic debris and associated polyethylene induced osteolysis. In all patients, (not just older individuals) use of an all polyethylene tibial component is an attractive and more cost effective alternative, and is associated with the best survivorship and lowest risk of revision.