header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

CLASSIFYING FEMORAL BONE DEFICIENCY: CHOOSING THE RIGHT IMPLANT

Current Concepts in Joint Replacement (CCJR) Spring 2016



Abstract

INTRODUCTION: As the number of patients who have undergone total hip arthroplasty rises, the number of patients who require surgery for a failed total hip arthroplasty is also increasing. It is estimated that 183,000 total hip replacements were performed in the United States in the year 2000 and that 31,000 of these (17%) were revision procedures. Reconstruction of the failed femoral component in revision total hip arthroplasty can be challenging from both a technical perspective and in pre-operative planning. With multiple reconstructive options available, it is helpful to have a classification system which guides the surgeon in selecting the appropriate method of reconstruction.

DISCUSSION: An extensively coated, diaphyseal filling component reliably achieves successful fixation in the majority of revision femurs. The surgical technique is straightforward and we continue to use this type of device in the majority of our revision total hip arthroplasties. However, in the severely damaged femur (Type IIIB and Type IV), other reconstructive options may provide improved results. Based on our results, the following reconstructive algorithm is recommended for femoral reconstruction in revision total hip arthroplasty: TYPE I: In a Type I femur, there is minimal loss of cancellous bone with an intact diaphysis. Cemented or cementless fixation can be utilised. If cemented fixation is selected, great care must be taken in removing the neo-cortex often encountered to allow for appropriate cement intrusion into the remaining cancellous bone. TYPE II: In a Type II femur, there is extensive loss of the metaphyseal cancellous bone and thus fixation with cement is unreliable. In this cohort of patients, successful fixation was achieved using a diaphyseal fitting, extensively porous coated implant in 26 of 29 cases (90%) However, as the metaphysis is supportive, a cementless implant that achieves primary fixation in the metaphysis can be utilized. TYPE III A: In a Type IIIA femur, the metaphysis is non-supportive and an extensively coated stem of adequate length is utilised to ensure that more than 4 cm of scratch fit is obtained in the diaphysis. TYPE III B: Based on the poor results obtained with a cylindrical, extensively porous coated implant, our present preference is a modular, cementless, tapered stem with flutes for obtaining rotational stability. Excellent results have been reported with this type of implant and by virtue of its tapered design, excellent initial axial stability can be obtained even in femurs with a very short isthmus. Subsidence has been reported as a potential problem with this type of implant and they can be difficult to insert. However, with the addition of modularity to many systems that employ this concept of fixation, improved stability can be obtained by impacting the femoral component as far distally as needed while then building up the proximal segment to restore appropriate leg length. TYPE IV: In a Type IV femur, the isthmus is completely non-supportive and the femoral canal is widened. Cementless fixation cannot be reliably used in our experience, as it is difficult to obtain adequate initial implant stability that is required for osseointegration. Reconstruction can be performed with impaction grafting if the cortical tube of the proximal femur is intact. However, this technique can be technically difficult to perform, time consuming and costly given the amount of bone graft that is often required. Although implant subsidence and peri-prosthetic fractures have been associated with this technique, it can provide an excellent solution for the difficult revision femur where cementless fixation cannot be utilised. Alternatively, an allograft-prosthesis composite can be utilised for younger patients in an attempt to reconstitute bone stock and a proximal femoral replacing endoprosthesis used for more elderly patients.