PATIENT FUNCTION FOLLOWING ASEPTIC REVISION TOTAL KNEE ARTHROPLASTY WITH SEMI-CONSTRAINED PROSTHESES IS THE SAME AS FOLLOWING PRIMARY KNEE ARTHROPLASTY

The British Orthopaedic Research Society (BORS) Annual Conference, September 2016



Abstract

Patient function is poorly characterised following revision TKA. Modern semi-constrained implants are suggested to offer high levels of function, however, data is lacking to justify this claim.

52 consecutive aseptic revision TKA procedures performed at a single centre were prospectively evaluated; all were revision of a primary implant to a Triathlon total stabiliser prosthesis. Patients were assessed pre-operatively and at 6, 26, 52 and 104 weeks post-op. Outcome assessments were the Oxford Knee Score (OKS), range of motion, pain rating scale and timed functional assessment battery. Analysis was by repeated measures ANOVA with post-hoc Tukey HSD 95% simultaneous confidence intervals as pairwise comparison. Secondary analysis compared the results of this revision cohort to previously reported primary TKA data, performed by the same surgeons, with identical outcome assessments at equivalent time points.

Mean age was 73.23 (SD 10.41) years, 57% were male. Mean time since index surgery was 9.03 (SD 5.6) years. 3 patients were lost to follow-up. All outcome parameters improved significantly over time (p <0.001). Post-hoc analysis demonstrated that all outcomes changed between pre-op, 6 week and 26 weeks post-op assessments.

No difference was seen between primary and revision cohorts in OKS (p = 0.2) or pain scores (p=0.19). Range of motion and functional performance was different between groups over the 2 year period (p=0.03), however this was due to differing pre-operative scores, post-hoc analysis showed no difference between groups at any post-operative time point.

Patients undergoing aseptic revision TKA with semi-constrained implants made substantial improvements in OKS, pain scores, knee flexion, and timed functional performance, with the outcomes achieved comparable to those of primary TKA. High levels of function can be achieved following revision knee arthroplasty, which may be important considering the changing need for, and demographics of, revision surgery.