Full Access

General Orthopaedics

MID-TERM FOLLOW-UP OF DIVERGENT PEG GLENOID COMPONENTS IN TOTAL SHOULDER ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 1.



Abstract

Background

Glenoid component aseptic loosening is the most common source of total shoulder arthroplasty (TSA) revision. In an attempt to strengthen cemented glenoid component fixation, divergent pegged glenoids were designed. Divergent peg creation was intended to increase cement purchase and provide resistance to component rocking.

Methods

Thirty-four patients who underwent divergent peg TSA had data collected prospectively. The data from these patients was retrospectively reviewed, primarily for radiographic evidence of glenoid component loosening. The endpoint was defined as the need for revision secondary to glenoid loosening. Secondary outcome measures such as SPADI (shoulder pain and disability index), active forward elevation, abduction, internal rotation, and external rotation were also collected. Data was obtained preoperatively and at the following postoperative intervals: 3 months, 6 months, and yearly. The last available postoperative radiographs were also reviewed and graded on a modified Franklin glenoid lucency scale described by Lazarus et al.

Results

The mean follow-up was 5.6 years ± 2.44 (range, 2–10 years). Of the 34 patients in the study, 20 patients had radiographs available for review. Radiographs showed complete lucency around one or less pegs in 14/20 patients (grade 0–2). Six out of twenty glenoids had complete radiolucency around two or more pegs with gross loosening seen in one shoulder (grade 3–5). No secondary surgery was performed in any patients. Significant improvements were seen in active elevation 30.2 degrees ±44.3 (p=0.043) at the last follow up. Improvement was also seen in internal rotation of 4.3 levels ± 4.9 (p=0.016) at the last follow-up. The mean postoperative SPADI score decreased by 48.1 points (p=0.039).

Conclusions

Patients with divergent pegged glenoid TSA showed significant improvement in postoperative shoulder elevation, internal rotation, and SPADI scores at final follow-up. No patients underwent revision. However, there were a significant number of patients with radiolucency seen around 2 or more pegs.