Abstract
Purpose
Traditional total knee arthoplasty techniques have involved implantation of diaphyseal stems to aid in fixation expecially when using constrained polyethylene inserts. While the debate over cemented vs uncemented stems continues, the actual use of stems is considered routine. The authors' experience with cemented stemmed knee revisions in older patients with osteoporotic bone has been favorable. Our younger patients with press-fit stems from varying manufacturers have been plagued with a relatively high incidence of component loosening and stem tip pain in the tibia and occasionally thigh. We report the early results of the first 20 total knee revisions using press-fit metaphyseal filling sleeved stemless implants with constrained bearings.
Methods
Twenty three patients with failed primary or revision total knees were assigned to receive stemless sleeved revision knee designs using the DePuy MBT/TC3 system. Reasons for revision included loosening, implant fracture, stiffness, instability, and stem pain. Twenty patients (ages ranging from 42–73) were successfully reconstructed without stems. Six knees with significant uncontained cavitary defects were included. Three patients with unexpectedly osteoporotic metaphyseal bone were revised with cemented stemmed implants and excluded. All cases used cement for initial fixation on the cut bone surface and fully constrained mobile bearing inserts.
Results
Follow up ranged from six months to three years. All patients had radiographic evidence of well fixed stable implants on most recent examination. All four cases of revision for “end of stem pain” had complete resolution of symptoms within two weeks of revision surgery. Long leg anterior posterior mechanical alignment x-rays measured within two degrees of neutral in all cases. Knee Society Scores improved an average of 34 points. Clinical results for revision for stiffness had the lowest final scores post operatively.
Conclusion
Stemmed total knee arthroplasty revision implants with or without cement are considered the standard for most revision reconstructions. Recently, primary total hip replacements using newer short metaphyseal stems have shown promising early clinical results. This case series of twenty total knee revisions using stemless press-fit metaphyseal sleeves shows similarly favorable outcomes. The complications of stemmed implants such as stem tip pain and difficulty of cemented stem removal can be avoided successfully in non-osteporotic bone reconstructions. With stable bony ingrowth visible on early post-operatyive radiographs, long term stable fixation even with constrained bearings is expected. Longer follow up will be needed to validate this technique for routine use.